Optical coefficient measurements using bulk living tissue with optical fiber puncture

Haruna Nakazawa, Marika Doi, Emiyu Ogawa, Tsunenori Arai

Research output: Contribution to journalArticle

Abstract

Slicing sample preparation in tissue optical characteristic measurement may makes huge error over individual optical differences. We proposed the combination of light intensity measurement through an optical fiber puncturing into a bulk tissue varying detection numerical aperture and ray tracing calculation to avoid slicing degradation of living tissue. To reveal the characteristics of this measurement, optical coefficients of pig myocardium obtained by the IAD method with slicing living tissue sample preparation and proposed measurement method were compared. In the proposed method, a silica fiber installed in an18G needle was punctured up to the bottom of the myocardial bulk tissue to measure light intensity in the bulk tissue changing depth and numerical aperture. The author found that measured apparent attenuation coefficients tended to strongly depend on numerical aperture. The ray trace calculation explained the same numerical aperture tendency in above mentioned experimental result. Optical characteristics of sliced myocardial samples revealed temporal change due to dehydration.

Original languageEnglish
Pages (from-to)597-598
Number of pages2
JournalTransactions of Japanese Society for Medical and Biological Engineering
Volume55
Issue numberProc
DOIs
Publication statusPublished - 2017

Fingerprint

Optical fibers
Tissue
Piercing
Ray tracing
Dehydration
Needles
Silica
Degradation
Fibers

Keywords

  • Numerical aperture
  • Optical coefficients
  • Optical fiber puncturing
  • Ray tracing calculation
  • Slicing sample preparations

ASJC Scopus subject areas

  • Biomedical Engineering

Cite this

Optical coefficient measurements using bulk living tissue with optical fiber puncture. / Nakazawa, Haruna; Doi, Marika; Ogawa, Emiyu; Arai, Tsunenori.

In: Transactions of Japanese Society for Medical and Biological Engineering, Vol. 55, No. Proc, 2017, p. 597-598.

Research output: Contribution to journalArticle

Nakazawa, Haruna ; Doi, Marika ; Ogawa, Emiyu ; Arai, Tsunenori. / Optical coefficient measurements using bulk living tissue with optical fiber puncture. In: Transactions of Japanese Society for Medical and Biological Engineering. 2017 ; Vol. 55, No. Proc. pp. 597-598.
@article{708d2e3a97ba43aab7e3590ddb8f3bb1,
title = "Optical coefficient measurements using bulk living tissue with optical fiber puncture",
abstract = "Slicing sample preparation in tissue optical characteristic measurement may makes huge error over individual optical differences. We proposed the combination of light intensity measurement through an optical fiber puncturing into a bulk tissue varying detection numerical aperture and ray tracing calculation to avoid slicing degradation of living tissue. To reveal the characteristics of this measurement, optical coefficients of pig myocardium obtained by the IAD method with slicing living tissue sample preparation and proposed measurement method were compared. In the proposed method, a silica fiber installed in an18G needle was punctured up to the bottom of the myocardial bulk tissue to measure light intensity in the bulk tissue changing depth and numerical aperture. The author found that measured apparent attenuation coefficients tended to strongly depend on numerical aperture. The ray trace calculation explained the same numerical aperture tendency in above mentioned experimental result. Optical characteristics of sliced myocardial samples revealed temporal change due to dehydration.",
keywords = "Numerical aperture, Optical coefficients, Optical fiber puncturing, Ray tracing calculation, Slicing sample preparations",
author = "Haruna Nakazawa and Marika Doi and Emiyu Ogawa and Tsunenori Arai",
year = "2017",
doi = "10.11239/jsmbe.55Annual.597",
language = "English",
volume = "55",
pages = "597--598",
journal = "BME = Bio medical engineering / henshu, Nihon ME Gakkai",
issn = "1347-443X",
publisher = "Nihon M E Gakkai",
number = "Proc",

}

TY - JOUR

T1 - Optical coefficient measurements using bulk living tissue with optical fiber puncture

AU - Nakazawa, Haruna

AU - Doi, Marika

AU - Ogawa, Emiyu

AU - Arai, Tsunenori

PY - 2017

Y1 - 2017

N2 - Slicing sample preparation in tissue optical characteristic measurement may makes huge error over individual optical differences. We proposed the combination of light intensity measurement through an optical fiber puncturing into a bulk tissue varying detection numerical aperture and ray tracing calculation to avoid slicing degradation of living tissue. To reveal the characteristics of this measurement, optical coefficients of pig myocardium obtained by the IAD method with slicing living tissue sample preparation and proposed measurement method were compared. In the proposed method, a silica fiber installed in an18G needle was punctured up to the bottom of the myocardial bulk tissue to measure light intensity in the bulk tissue changing depth and numerical aperture. The author found that measured apparent attenuation coefficients tended to strongly depend on numerical aperture. The ray trace calculation explained the same numerical aperture tendency in above mentioned experimental result. Optical characteristics of sliced myocardial samples revealed temporal change due to dehydration.

AB - Slicing sample preparation in tissue optical characteristic measurement may makes huge error over individual optical differences. We proposed the combination of light intensity measurement through an optical fiber puncturing into a bulk tissue varying detection numerical aperture and ray tracing calculation to avoid slicing degradation of living tissue. To reveal the characteristics of this measurement, optical coefficients of pig myocardium obtained by the IAD method with slicing living tissue sample preparation and proposed measurement method were compared. In the proposed method, a silica fiber installed in an18G needle was punctured up to the bottom of the myocardial bulk tissue to measure light intensity in the bulk tissue changing depth and numerical aperture. The author found that measured apparent attenuation coefficients tended to strongly depend on numerical aperture. The ray trace calculation explained the same numerical aperture tendency in above mentioned experimental result. Optical characteristics of sliced myocardial samples revealed temporal change due to dehydration.

KW - Numerical aperture

KW - Optical coefficients

KW - Optical fiber puncturing

KW - Ray tracing calculation

KW - Slicing sample preparations

UR - http://www.scopus.com/inward/record.url?scp=85029875272&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85029875272&partnerID=8YFLogxK

U2 - 10.11239/jsmbe.55Annual.597

DO - 10.11239/jsmbe.55Annual.597

M3 - Article

AN - SCOPUS:85029875272

VL - 55

SP - 597

EP - 598

JO - BME = Bio medical engineering / henshu, Nihon ME Gakkai

JF - BME = Bio medical engineering / henshu, Nihon ME Gakkai

SN - 1347-443X

IS - Proc

ER -