Abstract

Although lymphoscintigraphy is a useful method of detecting the sentinel nodes of malignancy, conventional lymphoscintigraphy images only the sentinel nodes without revealing their anatomical location. We, therefore, used scattered photons to attempt to outline the body contours of patients with either breast or esophageal cancer. Lymphoscintigraphy was performed 3 to 4 hours after the injection of 111 MBq of 99mTc tin colloid into the peritumoral region. Images were obtained with dual-energy windows of 130 to 150 keV for the primary photons and 70 to 110 keV for the scattered photons. The images constructed from the scattered photons clearly showed the contours of the body, and the fusion images constructed from the primary and scattered photons allowed for easy identification of the location of the sentinel nodes. The results of this study confirm that images obtained from scattered photons on lymphoscintigraphy are helpful in identifying the anatomical location of sentinel nodes.

Original languageEnglish
Pages (from-to)401-404
Number of pages4
JournalAnnals of Nuclear Medicine
Volume14
Issue number5
Publication statusPublished - 2000

Fingerprint

Lymphoscintigraphy
Photons
Tin
Body Image
Colloids
Esophageal Neoplasms
cyhalothrin
Breast Neoplasms
Injections
Neoplasms

Keywords

  • Tc tin colloid
  • Compton scattering
  • Lymphoscintigraphy
  • Scattered photon
  • Sentinel node

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Outlining the body contours with scattered photons in lymphoscintigraphy for sentinel nodes. / Fujii, H.; Yamashita, H.; Nakahara, Tadaki; Ikeda, T.; Kitagawa, Yuukou; Iwasaki, R.; Nakamura, K.; Sato, Masayasu; Hashimoto, J.; Kubo, A.

In: Annals of Nuclear Medicine, Vol. 14, No. 5, 2000, p. 401-404.

Research output: Contribution to journalArticle

Fujii, H, Yamashita, H, Nakahara, T, Ikeda, T, Kitagawa, Y, Iwasaki, R, Nakamura, K, Sato, M, Hashimoto, J & Kubo, A 2000, 'Outlining the body contours with scattered photons in lymphoscintigraphy for sentinel nodes', Annals of Nuclear Medicine, vol. 14, no. 5, pp. 401-404.
Fujii, H. ; Yamashita, H. ; Nakahara, Tadaki ; Ikeda, T. ; Kitagawa, Yuukou ; Iwasaki, R. ; Nakamura, K. ; Sato, Masayasu ; Hashimoto, J. ; Kubo, A. / Outlining the body contours with scattered photons in lymphoscintigraphy for sentinel nodes. In: Annals of Nuclear Medicine. 2000 ; Vol. 14, No. 5. pp. 401-404.
@article{493f93e7a0c740cd867a51aba2acf86e,
title = "Outlining the body contours with scattered photons in lymphoscintigraphy for sentinel nodes",
abstract = "Although lymphoscintigraphy is a useful method of detecting the sentinel nodes of malignancy, conventional lymphoscintigraphy images only the sentinel nodes without revealing their anatomical location. We, therefore, used scattered photons to attempt to outline the body contours of patients with either breast or esophageal cancer. Lymphoscintigraphy was performed 3 to 4 hours after the injection of 111 MBq of 99mTc tin colloid into the peritumoral region. Images were obtained with dual-energy windows of 130 to 150 keV for the primary photons and 70 to 110 keV for the scattered photons. The images constructed from the scattered photons clearly showed the contours of the body, and the fusion images constructed from the primary and scattered photons allowed for easy identification of the location of the sentinel nodes. The results of this study confirm that images obtained from scattered photons on lymphoscintigraphy are helpful in identifying the anatomical location of sentinel nodes.",
keywords = "Tc tin colloid, Compton scattering, Lymphoscintigraphy, Scattered photon, Sentinel node",
author = "H. Fujii and H. Yamashita and Tadaki Nakahara and T. Ikeda and Yuukou Kitagawa and R. Iwasaki and K. Nakamura and Masayasu Sato and J. Hashimoto and A. Kubo",
year = "2000",
language = "English",
volume = "14",
pages = "401--404",
journal = "Annals of Nuclear Medicine",
issn = "0914-7187",
publisher = "Springer Japan",
number = "5",

}

TY - JOUR

T1 - Outlining the body contours with scattered photons in lymphoscintigraphy for sentinel nodes

AU - Fujii, H.

AU - Yamashita, H.

AU - Nakahara, Tadaki

AU - Ikeda, T.

AU - Kitagawa, Yuukou

AU - Iwasaki, R.

AU - Nakamura, K.

AU - Sato, Masayasu

AU - Hashimoto, J.

AU - Kubo, A.

PY - 2000

Y1 - 2000

N2 - Although lymphoscintigraphy is a useful method of detecting the sentinel nodes of malignancy, conventional lymphoscintigraphy images only the sentinel nodes without revealing their anatomical location. We, therefore, used scattered photons to attempt to outline the body contours of patients with either breast or esophageal cancer. Lymphoscintigraphy was performed 3 to 4 hours after the injection of 111 MBq of 99mTc tin colloid into the peritumoral region. Images were obtained with dual-energy windows of 130 to 150 keV for the primary photons and 70 to 110 keV for the scattered photons. The images constructed from the scattered photons clearly showed the contours of the body, and the fusion images constructed from the primary and scattered photons allowed for easy identification of the location of the sentinel nodes. The results of this study confirm that images obtained from scattered photons on lymphoscintigraphy are helpful in identifying the anatomical location of sentinel nodes.

AB - Although lymphoscintigraphy is a useful method of detecting the sentinel nodes of malignancy, conventional lymphoscintigraphy images only the sentinel nodes without revealing their anatomical location. We, therefore, used scattered photons to attempt to outline the body contours of patients with either breast or esophageal cancer. Lymphoscintigraphy was performed 3 to 4 hours after the injection of 111 MBq of 99mTc tin colloid into the peritumoral region. Images were obtained with dual-energy windows of 130 to 150 keV for the primary photons and 70 to 110 keV for the scattered photons. The images constructed from the scattered photons clearly showed the contours of the body, and the fusion images constructed from the primary and scattered photons allowed for easy identification of the location of the sentinel nodes. The results of this study confirm that images obtained from scattered photons on lymphoscintigraphy are helpful in identifying the anatomical location of sentinel nodes.

KW - Tc tin colloid

KW - Compton scattering

KW - Lymphoscintigraphy

KW - Scattered photon

KW - Sentinel node

UR - http://www.scopus.com/inward/record.url?scp=0033661790&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033661790&partnerID=8YFLogxK

M3 - Article

VL - 14

SP - 401

EP - 404

JO - Annals of Nuclear Medicine

JF - Annals of Nuclear Medicine

SN - 0914-7187

IS - 5

ER -