Performance Evaluation of Platelet Counting by Novel Fluorescent Dye Staining in the XN-Series Automated Hematology Analyzers

Yuzo Tanaka, Yumiko Tanaka, Kazumi Gondo, Yoshiko Maruki, Tamiaki Kondo, Satomi Asai, Hiromichi Matsushita, Hayato Miyachi

Research output: Contribution to journalArticlepeer-review

39 Citations (Scopus)

Abstract

Background: Conventional automated hematology analyzers have limitations in platelet measurements such as poor accuracy and precision in the low count range and interference by nonplatelet particles. In order to improve it, the newly developed XN-Series automated hematology analyzers (Sysmex Corporation, Kobe, Japan) have been installed with a new dedicated channel for platelet analysis (PLT-F), which is based on a fluorescence flow cytometry method with uses of a novel fluorescent dye specifically staining platelets. We evaluated the basic performance of this new PLT-F channel. Methods: Basic performance of the PLT-F channel in within-run reproducibility and assay linearity was studied using standard methods. Correlation was studied between PLT-F and a conventional automated hematology analyzer (XE-2100) and immunoplatelet analysis using anti-CD61 monoclonal antibody (Cell-Dyn Sapphire; Abbott Laboratories). The assay interference by nonplatelet particles such as fragmented red and white blood cells was evaluated by using clinical samples, respectively, from burn injury and acute leukemia. Results: Basic performance of the PLT-F platelet counting was satisfactory in within-run reproducibility, linearity and correlation with the conventional analyzer. The correlation was satisfactory also with the immunoplatelet analysis, even for samples from a patient with burn injury, and those with white blood cell fragments displayed, platelet abnormal flag and low platelet counts (<50 × 109/l). Conclusion: The platelet counting performance of the PLT-F channel of the XN Series had improved accuracy and precision in the low range and in abnormal samples, avoiding the interference by nonplatelet particles.

Original languageEnglish
Pages (from-to)341-348
Number of pages8
JournalJournal of Clinical Laboratory Analysis
Volume28
Issue number5
DOIs
Publication statusPublished - 2014 Sept
Externally publishedYes

Keywords

  • Automated hematology analyzer
  • Nonplatelet particle
  • PLT-F channel
  • Platelet counting
  • Thrombocytopenia

ASJC Scopus subject areas

  • Immunology and Allergy
  • Hematology
  • Public Health, Environmental and Occupational Health
  • Clinical Biochemistry
  • Medical Laboratory Technology
  • Biochemistry, medical
  • Microbiology (medical)

Fingerprint

Dive into the research topics of 'Performance Evaluation of Platelet Counting by Novel Fluorescent Dye Staining in the XN-Series Automated Hematology Analyzers'. Together they form a unique fingerprint.

Cite this