Practical realization of enfold connecting system of artificial blood vessel for simplifying maintenance surgery evaluation of thrombus formation and blood coagulation capasity

A. Watanabe, T. Ota, Y. Kanno, Norihisa Miki

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Evaluations for the enfold connecting system of system is developed to reduce and simplify the maintenance surgery of the artificial organ.The connector is designed not to contact the blood directly and the artificial blood vessel enfolds metal pipe in connector. Thanks to this design, the biocompatibility of the connector is comparable with an artificial vessel. We confirmed the blood coagulate protein which form a thrombus at the joint point of the connector with SEM. And we also measured a potential of blood coagulation by activated partial thromboplastin time (APTT). We didn't find the remarkable increase of blood coagulation on the connecting point for 72 hours. And APTT decreased a little in the experiment of a blood circulation system with the connector but we can't conclude that the connector causes a blood coagulation from results for 120 minutes. Additionally, we measured a potential of blood coagulation by APTT about the micro dialysis device which is developed in our group. We conducted the micro dialysis device experiments as with the same method of the connector experiments of APTT. We did not observe the remarkable disease of APTT for 120 minutes about the micro dialysis device as well. However, we found that the hemolysis was possible to be occurred in the micro dialysis device.

Original languageEnglish
Title of host publication2018 International Conference on Electronics Packaging and iMAPS All Asia Conference, ICEP-IAAC 2018
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages141-144
Number of pages4
ISBN (Electronic)9784990218850
DOIs
Publication statusPublished - 2018 Jun 6
Event2018 International Conference on Electronics Packaging and iMAPS All Asia Conference, ICEP-IAAC 2018 - Kuwana, Mie, Japan
Duration: 2018 Apr 172018 Apr 21

Other

Other2018 International Conference on Electronics Packaging and iMAPS All Asia Conference, ICEP-IAAC 2018
CountryJapan
CityKuwana, Mie
Period18/4/1718/4/21

Fingerprint

Blood vessel prostheses
Coagulation
Surgery
Thromboplastin
Blood
Artificial organs
Experiments
Hemodynamics
Biocompatibility
Metals
Pipe
Proteins
Scanning electron microscopy
Microdialysis

Keywords

  • artificial blood vessel
  • blood coagulation
  • connector
  • medical use

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Electronic, Optical and Magnetic Materials
  • Polymers and Plastics

Cite this

Watanabe, A., Ota, T., Kanno, Y., & Miki, N. (2018). Practical realization of enfold connecting system of artificial blood vessel for simplifying maintenance surgery evaluation of thrombus formation and blood coagulation capasity. In 2018 International Conference on Electronics Packaging and iMAPS All Asia Conference, ICEP-IAAC 2018 (pp. 141-144). Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.23919/ICEP.2018.8374689

Practical realization of enfold connecting system of artificial blood vessel for simplifying maintenance surgery evaluation of thrombus formation and blood coagulation capasity. / Watanabe, A.; Ota, T.; Kanno, Y.; Miki, Norihisa.

2018 International Conference on Electronics Packaging and iMAPS All Asia Conference, ICEP-IAAC 2018. Institute of Electrical and Electronics Engineers Inc., 2018. p. 141-144.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Watanabe, A, Ota, T, Kanno, Y & Miki, N 2018, Practical realization of enfold connecting system of artificial blood vessel for simplifying maintenance surgery evaluation of thrombus formation and blood coagulation capasity. in 2018 International Conference on Electronics Packaging and iMAPS All Asia Conference, ICEP-IAAC 2018. Institute of Electrical and Electronics Engineers Inc., pp. 141-144, 2018 International Conference on Electronics Packaging and iMAPS All Asia Conference, ICEP-IAAC 2018, Kuwana, Mie, Japan, 18/4/17. https://doi.org/10.23919/ICEP.2018.8374689
Watanabe A, Ota T, Kanno Y, Miki N. Practical realization of enfold connecting system of artificial blood vessel for simplifying maintenance surgery evaluation of thrombus formation and blood coagulation capasity. In 2018 International Conference on Electronics Packaging and iMAPS All Asia Conference, ICEP-IAAC 2018. Institute of Electrical and Electronics Engineers Inc. 2018. p. 141-144 https://doi.org/10.23919/ICEP.2018.8374689
Watanabe, A. ; Ota, T. ; Kanno, Y. ; Miki, Norihisa. / Practical realization of enfold connecting system of artificial blood vessel for simplifying maintenance surgery evaluation of thrombus formation and blood coagulation capasity. 2018 International Conference on Electronics Packaging and iMAPS All Asia Conference, ICEP-IAAC 2018. Institute of Electrical and Electronics Engineers Inc., 2018. pp. 141-144
@inproceedings{36e27236c3344dbeb39ffb501194b963,
title = "Practical realization of enfold connecting system of artificial blood vessel for simplifying maintenance surgery evaluation of thrombus formation and blood coagulation capasity",
abstract = "Evaluations for the enfold connecting system of system is developed to reduce and simplify the maintenance surgery of the artificial organ.The connector is designed not to contact the blood directly and the artificial blood vessel enfolds metal pipe in connector. Thanks to this design, the biocompatibility of the connector is comparable with an artificial vessel. We confirmed the blood coagulate protein which form a thrombus at the joint point of the connector with SEM. And we also measured a potential of blood coagulation by activated partial thromboplastin time (APTT). We didn't find the remarkable increase of blood coagulation on the connecting point for 72 hours. And APTT decreased a little in the experiment of a blood circulation system with the connector but we can't conclude that the connector causes a blood coagulation from results for 120 minutes. Additionally, we measured a potential of blood coagulation by APTT about the micro dialysis device which is developed in our group. We conducted the micro dialysis device experiments as with the same method of the connector experiments of APTT. We did not observe the remarkable disease of APTT for 120 minutes about the micro dialysis device as well. However, we found that the hemolysis was possible to be occurred in the micro dialysis device.",
keywords = "artificial blood vessel, blood coagulation, connector, medical use",
author = "A. Watanabe and T. Ota and Y. Kanno and Norihisa Miki",
year = "2018",
month = "6",
day = "6",
doi = "10.23919/ICEP.2018.8374689",
language = "English",
pages = "141--144",
booktitle = "2018 International Conference on Electronics Packaging and iMAPS All Asia Conference, ICEP-IAAC 2018",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - GEN

T1 - Practical realization of enfold connecting system of artificial blood vessel for simplifying maintenance surgery evaluation of thrombus formation and blood coagulation capasity

AU - Watanabe, A.

AU - Ota, T.

AU - Kanno, Y.

AU - Miki, Norihisa

PY - 2018/6/6

Y1 - 2018/6/6

N2 - Evaluations for the enfold connecting system of system is developed to reduce and simplify the maintenance surgery of the artificial organ.The connector is designed not to contact the blood directly and the artificial blood vessel enfolds metal pipe in connector. Thanks to this design, the biocompatibility of the connector is comparable with an artificial vessel. We confirmed the blood coagulate protein which form a thrombus at the joint point of the connector with SEM. And we also measured a potential of blood coagulation by activated partial thromboplastin time (APTT). We didn't find the remarkable increase of blood coagulation on the connecting point for 72 hours. And APTT decreased a little in the experiment of a blood circulation system with the connector but we can't conclude that the connector causes a blood coagulation from results for 120 minutes. Additionally, we measured a potential of blood coagulation by APTT about the micro dialysis device which is developed in our group. We conducted the micro dialysis device experiments as with the same method of the connector experiments of APTT. We did not observe the remarkable disease of APTT for 120 minutes about the micro dialysis device as well. However, we found that the hemolysis was possible to be occurred in the micro dialysis device.

AB - Evaluations for the enfold connecting system of system is developed to reduce and simplify the maintenance surgery of the artificial organ.The connector is designed not to contact the blood directly and the artificial blood vessel enfolds metal pipe in connector. Thanks to this design, the biocompatibility of the connector is comparable with an artificial vessel. We confirmed the blood coagulate protein which form a thrombus at the joint point of the connector with SEM. And we also measured a potential of blood coagulation by activated partial thromboplastin time (APTT). We didn't find the remarkable increase of blood coagulation on the connecting point for 72 hours. And APTT decreased a little in the experiment of a blood circulation system with the connector but we can't conclude that the connector causes a blood coagulation from results for 120 minutes. Additionally, we measured a potential of blood coagulation by APTT about the micro dialysis device which is developed in our group. We conducted the micro dialysis device experiments as with the same method of the connector experiments of APTT. We did not observe the remarkable disease of APTT for 120 minutes about the micro dialysis device as well. However, we found that the hemolysis was possible to be occurred in the micro dialysis device.

KW - artificial blood vessel

KW - blood coagulation

KW - connector

KW - medical use

UR - http://www.scopus.com/inward/record.url?scp=85048824678&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85048824678&partnerID=8YFLogxK

U2 - 10.23919/ICEP.2018.8374689

DO - 10.23919/ICEP.2018.8374689

M3 - Conference contribution

AN - SCOPUS:85048824678

SP - 141

EP - 144

BT - 2018 International Conference on Electronics Packaging and iMAPS All Asia Conference, ICEP-IAAC 2018

PB - Institute of Electrical and Electronics Engineers Inc.

ER -