T1 - Refractive outcomes of intraocular lens power calculation using different corneal power measurements with a new optical biometer
AU - Savini, Giacomo
AU - Negishi, Kazuno
AU - Hoffer, Kenneth J.
AU - Lomoriello, Domenico Schiano
N1 - Funding Information:
The contribution of G.B. Bietti Foundation IRCCS was supported by the Italian Ministry of Health and Fondazione Roma, Rome, Italy.
Publisher Copyright:
© 2018 ASCRS and ESCRS
Copyright:
Copyright 2018 Elsevier B.V., All rights reserved.
PY - 2018/6
Y1 - 2018/6
N2 - Purpose: To evaluate the results of intraocular lens (IOL) power calculation using different corneal power measurements provided by an optical biometer combined with a dual Scheimpflug analyzer and a Placido disk topographer (Galilei G6). Setting: G.B. Bietti Foundation, Rome, Italy, and Keio University Hospital, Tokyo, Japan. Design: Evaluation of diagnostic technology. Methods: Consecutive patients having cataract surgery were enrolled. The IOL power was calculated with the Barrett Universal II, Haigis, Hoffer Q, Holladay 1, and SRK/T formulas. Different options were used to calculate the corneal power: simulated keratometry (K) based on anterior corneal surface measurements only and total corneal power (TCP) based on ray tracing through both corneal surfaces. Three TCP measurements (TCP1, TCP2, and TCP-IOL) were evaluated. Results: The study analyzed 118 eyes. The mean values of simulated K (43.74 diopters [D] ± 1.40 [SD]), TCP1 (43.13 ± 1.35 D), TCP2 (41.87 ± 1.30 D), and TCP-IOL (42.62 ± 1.35 D) were significantly different (P <.0001). The best results were obtained using simulated K: the median absolute error ranged between 0.22 D and 0.29 D and the percentage of eyes with a prediction error of ±0.50 D or less, between 76.2% and 84.7%, depending on the formula. After constant optimization, the results using any TCP value and simulated K were similar with no statistically significant differences. Conclusions: Biometric measurements provided by the Scheimpflug–Placido optical biometer can be used to accurately calculate the IOL power. Simulated K and TCP led to similar outcomes after constant optimization.
AB - Purpose: To evaluate the results of intraocular lens (IOL) power calculation using different corneal power measurements provided by an optical biometer combined with a dual Scheimpflug analyzer and a Placido disk topographer (Galilei G6). Setting: G.B. Bietti Foundation, Rome, Italy, and Keio University Hospital, Tokyo, Japan. Design: Evaluation of diagnostic technology. Methods: Consecutive patients having cataract surgery were enrolled. The IOL power was calculated with the Barrett Universal II, Haigis, Hoffer Q, Holladay 1, and SRK/T formulas. Different options were used to calculate the corneal power: simulated keratometry (K) based on anterior corneal surface measurements only and total corneal power (TCP) based on ray tracing through both corneal surfaces. Three TCP measurements (TCP1, TCP2, and TCP-IOL) were evaluated. Results: The study analyzed 118 eyes. The mean values of simulated K (43.74 diopters [D] ± 1.40 [SD]), TCP1 (43.13 ± 1.35 D), TCP2 (41.87 ± 1.30 D), and TCP-IOL (42.62 ± 1.35 D) were significantly different (P <.0001). The best results were obtained using simulated K: the median absolute error ranged between 0.22 D and 0.29 D and the percentage of eyes with a prediction error of ±0.50 D or less, between 76.2% and 84.7%, depending on the formula. After constant optimization, the results using any TCP value and simulated K were similar with no statistically significant differences. Conclusions: Biometric measurements provided by the Scheimpflug–Placido optical biometer can be used to accurately calculate the IOL power. Simulated K and TCP led to similar outcomes after constant optimization.
UR - http://www.scopus.com/inward/record.url?scp=85048592519&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85048592519&partnerID=8YFLogxK
U2 - 10.1016/j.jcrs.2018.03.027
DO - 10.1016/j.jcrs.2018.03.027
M3 - Article
C2 - 29861053
AN - SCOPUS:85048592519
SN - 0886-3350
VL - 44
SP - 701
EP - 708
JO - Journal of Cataract and Refractive Surgery
JF - Journal of Cataract and Refractive Surgery
IS - 6
ER -