Relations between a net electrical output power and dimensions of components in radial build are investigated based on the ITER plasma performance to develop a conceptual design of DEMO with the net electrical output power of several hundred MW. Reducing the dimensions of in-vessel components and increasing the thickness of the toroidal field coil contribute to strengthen the toroidal magnetic field at plasma, which brings about increase in a net electrical output power. The relation between the minimum plasma major radius and the maximum net electrical output power is clarified. Furthermore effects of improvements in the ITER plasma performance on the net electricity are also analyzed; indicating the increase of normalized beta could have advantage from the viewpoint of the divertor heat load because the increase of synchrotron radiation loss power contributes to reduce the divertor heat load, though the higher energy confinement is required.

Original languageEnglish
Pages (from-to)2440-2445
Number of pages6
JournalFusion Engineering and Design
Volume89
Issue number9-10
DOIs
Publication statusPublished - 2014 Jan 1
Externally publishedYes

Fingerprint

Plasmas
Thermal load
Conceptual design
Synchrotron radiation
Electricity
Magnetic fields

Keywords

  • DEMO
  • Net electric power
  • Plasma performance
  • Radial build

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Nuclear Energy and Engineering
  • Materials Science(all)
  • Mechanical Engineering

Cite this

Relationship between net electric power and radial build of DEMO based on ITER steady-state scenario parameters. / Sakamoto, Y.; Nakamura, M.; Tobita, K.; Utoh, H.; Someya, Y.; Hoshino, Kazuo; Asakura, N.; Tokunaga, S.

In: Fusion Engineering and Design, Vol. 89, No. 9-10, 01.01.2014, p. 2440-2445.

Research output: Contribution to journalArticle

Sakamoto, Y. ; Nakamura, M. ; Tobita, K. ; Utoh, H. ; Someya, Y. ; Hoshino, Kazuo ; Asakura, N. ; Tokunaga, S. / Relationship between net electric power and radial build of DEMO based on ITER steady-state scenario parameters. In: Fusion Engineering and Design. 2014 ; Vol. 89, No. 9-10. pp. 2440-2445.
@article{7066606ab8534f5c9ff2f61a72e5d8af,
title = "Relationship between net electric power and radial build of DEMO based on ITER steady-state scenario parameters",
abstract = "Relations between a net electrical output power and dimensions of components in radial build are investigated based on the ITER plasma performance to develop a conceptual design of DEMO with the net electrical output power of several hundred MW. Reducing the dimensions of in-vessel components and increasing the thickness of the toroidal field coil contribute to strengthen the toroidal magnetic field at plasma, which brings about increase in a net electrical output power. The relation between the minimum plasma major radius and the maximum net electrical output power is clarified. Furthermore effects of improvements in the ITER plasma performance on the net electricity are also analyzed; indicating the increase of normalized beta could have advantage from the viewpoint of the divertor heat load because the increase of synchrotron radiation loss power contributes to reduce the divertor heat load, though the higher energy confinement is required.",
keywords = "DEMO, Net electric power, Plasma performance, Radial build",
author = "Y. Sakamoto and M. Nakamura and K. Tobita and H. Utoh and Y. Someya and Kazuo Hoshino and N. Asakura and S. Tokunaga",
year = "2014",
month = "1",
day = "1",
doi = "10.1016/j.fusengdes.2014.04.032",
language = "English",
volume = "89",
pages = "2440--2445",
journal = "Fusion Engineering and Design",
issn = "0920-3796",
publisher = "Elsevier BV",
number = "9-10",

}

TY - JOUR

T1 - Relationship between net electric power and radial build of DEMO based on ITER steady-state scenario parameters

AU - Sakamoto, Y.

AU - Nakamura, M.

AU - Tobita, K.

AU - Utoh, H.

AU - Someya, Y.

AU - Hoshino, Kazuo

AU - Asakura, N.

AU - Tokunaga, S.

PY - 2014/1/1

Y1 - 2014/1/1

N2 - Relations between a net electrical output power and dimensions of components in radial build are investigated based on the ITER plasma performance to develop a conceptual design of DEMO with the net electrical output power of several hundred MW. Reducing the dimensions of in-vessel components and increasing the thickness of the toroidal field coil contribute to strengthen the toroidal magnetic field at plasma, which brings about increase in a net electrical output power. The relation between the minimum plasma major radius and the maximum net electrical output power is clarified. Furthermore effects of improvements in the ITER plasma performance on the net electricity are also analyzed; indicating the increase of normalized beta could have advantage from the viewpoint of the divertor heat load because the increase of synchrotron radiation loss power contributes to reduce the divertor heat load, though the higher energy confinement is required.

AB - Relations between a net electrical output power and dimensions of components in radial build are investigated based on the ITER plasma performance to develop a conceptual design of DEMO with the net electrical output power of several hundred MW. Reducing the dimensions of in-vessel components and increasing the thickness of the toroidal field coil contribute to strengthen the toroidal magnetic field at plasma, which brings about increase in a net electrical output power. The relation between the minimum plasma major radius and the maximum net electrical output power is clarified. Furthermore effects of improvements in the ITER plasma performance on the net electricity are also analyzed; indicating the increase of normalized beta could have advantage from the viewpoint of the divertor heat load because the increase of synchrotron radiation loss power contributes to reduce the divertor heat load, though the higher energy confinement is required.

KW - DEMO

KW - Net electric power

KW - Plasma performance

KW - Radial build

UR - http://www.scopus.com/inward/record.url?scp=84905900065&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84905900065&partnerID=8YFLogxK

U2 - 10.1016/j.fusengdes.2014.04.032

DO - 10.1016/j.fusengdes.2014.04.032

M3 - Article

AN - SCOPUS:84905900065

VL - 89

SP - 2440

EP - 2445

JO - Fusion Engineering and Design

JF - Fusion Engineering and Design

SN - 0920-3796

IS - 9-10

ER -