Same-Size Donor Corneas for Myopic Keratoconus

Shigeto Shimmura, Masako Ando, Misaki Ishioka, Jun Shimazaki, Kazuo Tsubota

Research output: Contribution to journalArticle

20 Citations (Scopus)

Abstract

Objective: To determine the efficacy of using same-size donor grafts for keratoconus patients with axial myopia. Methods: A prospective noncomparative interventional case series was performed on 142 eyes of 136 consecutive keratoconus patients. Penetrating keratoplasty (PKP) was performed by 3 skilled surgeons using the same technique with a single running 10-0 nylon suture. Donor button size was determined by a study protocol, where a same-size donor was used for eyes with an axial length (AXL) longer than 24.50 mm, whereas a 0.25-mm-oversized donor was used for eyes shorter than 24.49 mm. Postoperative spherical equivalent (SE) and incidence of postoperative complications were analyzed. Results: Of the 142 consecutive eyes, 123 eyes were operated according to protocol. The average postoperative SE on last visit was -3.94 ± 3.21 D, with an average uncorrected visual acuity of 0.28 (0.90 average corrected). Postoperative SE correlated inversely (r = 0.46) with preoperative axial length (AXL) expressed by the equation: SE = -0.15 (AXL) 2 + 6.40 (AXL) - 71.82. Graft rejection was observed in 7 eyes (5.7%), and glaucoma in 2 eyes that required surgery. Conclusions: Using same-size donor grafts in keratoconus patients with a long visual axis is a safe and effective procedure in reducing postoperative myopia.

Original languageEnglish
Pages (from-to)345-349
Number of pages5
JournalCornea
Volume23
Issue number4
DOIs
Publication statusPublished - 2004 May
Externally publishedYes

Fingerprint

Keratoconus
Cornea
Tissue Donors
Myopia
Eye Axial Length
Transplants
Penetrating Keratoplasty
Nylons
Graft Rejection
Glaucoma
Sutures
Visual Acuity
Incidence

Keywords

  • Donor cornea size
  • Keratoconus
  • Keratoplasty

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Same-Size Donor Corneas for Myopic Keratoconus. / Shimmura, Shigeto; Ando, Masako; Ishioka, Misaki; Shimazaki, Jun; Tsubota, Kazuo.

In: Cornea, Vol. 23, No. 4, 05.2004, p. 345-349.

Research output: Contribution to journalArticle

Shimmura, Shigeto ; Ando, Masako ; Ishioka, Misaki ; Shimazaki, Jun ; Tsubota, Kazuo. / Same-Size Donor Corneas for Myopic Keratoconus. In: Cornea. 2004 ; Vol. 23, No. 4. pp. 345-349.
@article{44d1999b18674bceb4534e5a416eef65,
title = "Same-Size Donor Corneas for Myopic Keratoconus",
abstract = "Objective: To determine the efficacy of using same-size donor grafts for keratoconus patients with axial myopia. Methods: A prospective noncomparative interventional case series was performed on 142 eyes of 136 consecutive keratoconus patients. Penetrating keratoplasty (PKP) was performed by 3 skilled surgeons using the same technique with a single running 10-0 nylon suture. Donor button size was determined by a study protocol, where a same-size donor was used for eyes with an axial length (AXL) longer than 24.50 mm, whereas a 0.25-mm-oversized donor was used for eyes shorter than 24.49 mm. Postoperative spherical equivalent (SE) and incidence of postoperative complications were analyzed. Results: Of the 142 consecutive eyes, 123 eyes were operated according to protocol. The average postoperative SE on last visit was -3.94 ± 3.21 D, with an average uncorrected visual acuity of 0.28 (0.90 average corrected). Postoperative SE correlated inversely (r = 0.46) with preoperative axial length (AXL) expressed by the equation: SE = -0.15 (AXL) 2 + 6.40 (AXL) - 71.82. Graft rejection was observed in 7 eyes (5.7{\%}), and glaucoma in 2 eyes that required surgery. Conclusions: Using same-size donor grafts in keratoconus patients with a long visual axis is a safe and effective procedure in reducing postoperative myopia.",
keywords = "Donor cornea size, Keratoconus, Keratoplasty",
author = "Shigeto Shimmura and Masako Ando and Misaki Ishioka and Jun Shimazaki and Kazuo Tsubota",
year = "2004",
month = "5",
doi = "10.1097/00003226-200405000-00006",
language = "English",
volume = "23",
pages = "345--349",
journal = "Cornea",
issn = "0277-3740",
publisher = "Lippincott Williams and Wilkins",
number = "4",

}

TY - JOUR

T1 - Same-Size Donor Corneas for Myopic Keratoconus

AU - Shimmura, Shigeto

AU - Ando, Masako

AU - Ishioka, Misaki

AU - Shimazaki, Jun

AU - Tsubota, Kazuo

PY - 2004/5

Y1 - 2004/5

N2 - Objective: To determine the efficacy of using same-size donor grafts for keratoconus patients with axial myopia. Methods: A prospective noncomparative interventional case series was performed on 142 eyes of 136 consecutive keratoconus patients. Penetrating keratoplasty (PKP) was performed by 3 skilled surgeons using the same technique with a single running 10-0 nylon suture. Donor button size was determined by a study protocol, where a same-size donor was used for eyes with an axial length (AXL) longer than 24.50 mm, whereas a 0.25-mm-oversized donor was used for eyes shorter than 24.49 mm. Postoperative spherical equivalent (SE) and incidence of postoperative complications were analyzed. Results: Of the 142 consecutive eyes, 123 eyes were operated according to protocol. The average postoperative SE on last visit was -3.94 ± 3.21 D, with an average uncorrected visual acuity of 0.28 (0.90 average corrected). Postoperative SE correlated inversely (r = 0.46) with preoperative axial length (AXL) expressed by the equation: SE = -0.15 (AXL) 2 + 6.40 (AXL) - 71.82. Graft rejection was observed in 7 eyes (5.7%), and glaucoma in 2 eyes that required surgery. Conclusions: Using same-size donor grafts in keratoconus patients with a long visual axis is a safe and effective procedure in reducing postoperative myopia.

AB - Objective: To determine the efficacy of using same-size donor grafts for keratoconus patients with axial myopia. Methods: A prospective noncomparative interventional case series was performed on 142 eyes of 136 consecutive keratoconus patients. Penetrating keratoplasty (PKP) was performed by 3 skilled surgeons using the same technique with a single running 10-0 nylon suture. Donor button size was determined by a study protocol, where a same-size donor was used for eyes with an axial length (AXL) longer than 24.50 mm, whereas a 0.25-mm-oversized donor was used for eyes shorter than 24.49 mm. Postoperative spherical equivalent (SE) and incidence of postoperative complications were analyzed. Results: Of the 142 consecutive eyes, 123 eyes were operated according to protocol. The average postoperative SE on last visit was -3.94 ± 3.21 D, with an average uncorrected visual acuity of 0.28 (0.90 average corrected). Postoperative SE correlated inversely (r = 0.46) with preoperative axial length (AXL) expressed by the equation: SE = -0.15 (AXL) 2 + 6.40 (AXL) - 71.82. Graft rejection was observed in 7 eyes (5.7%), and glaucoma in 2 eyes that required surgery. Conclusions: Using same-size donor grafts in keratoconus patients with a long visual axis is a safe and effective procedure in reducing postoperative myopia.

KW - Donor cornea size

KW - Keratoconus

KW - Keratoplasty

UR - http://www.scopus.com/inward/record.url?scp=2142647887&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=2142647887&partnerID=8YFLogxK

U2 - 10.1097/00003226-200405000-00006

DO - 10.1097/00003226-200405000-00006

M3 - Article

C2 - 15097127

AN - SCOPUS:2142647887

VL - 23

SP - 345

EP - 349

JO - Cornea

JF - Cornea

SN - 0277-3740

IS - 4

ER -