Sentinel node mapping with thermoresponsive magnetic nanoparticles in rats

Kunihiko Hiraiwa, Masakazu Ueda, Hiroya Takeuchi, Takashi Oyama, Tomoyuki Irino, Takahisa Yoshikawa, Akihiko Kondo, Yuukou Kitagawa

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

Background: In this study, we investigated the ability of magnetic resonance imaging (MRI) after interstitial administration of thermoresponsive magnetic nanoparticles to detect the sentinel lymph node (SLN). Materials and Methods: Postcontrast MRI scans were acquired following subcutaneous injection of thermoresponsive magnetic nanoparticles into the thoracic wall of rats. The signal-to-noise ratio of axillary lymph nodes was calculated to assess whether the SLN could be detected by MRI. In a second experiment, after injecting thermoresponsive magnetic nanoparticles, i.e., Therma-Max 36, Therma-Max 42, Therma-Max 55, and Ferridex, into the subserosa of the cecum of rats, the injection sites, the SLNs, and the distant lymph nodes were resected and examined histologically in order to determine which nanoparticles, if any, were specifically retained in the SLN. Results: MRI showed that the signal-to-noise ratio of axillary SLNs was significantly lower 24 h after injection of Therma-Max 42 than on the precontrast images (P < 0.05). Histologic evaluation revealed that Therma-Max 36 aggregated at body temperature and did not migrate to the SLN. Therma-Max 42, on the other hand, aggregated, and the particles became large enough to be retained in the SLNs. Therma-Max 55 and Ferridex did not aggregate, and they both migrated to the SLNs and the distant lymph nodes. Conclusions: The results of this study showed that thermoresponsive magnetic nanoparticles could be targeted to the SLN by adjusting the temperature at which they aggregate, and that they could be used as a contrast agent for SLN mapping by MRI.

Original languageEnglish
Pages (from-to)48-55
Number of pages8
JournalJournal of Surgical Research
Volume174
Issue number1
DOIs
Publication statusPublished - 2012 May 1

Fingerprint

Nanoparticles
Magnetic Resonance Imaging
Lymph Nodes
Signal-To-Noise Ratio
Injections
Cecum
Thoracic Wall
Subcutaneous Injections
Body Temperature
Contrast Media
cyhalothrin
Sentinel Lymph Node
Temperature

Keywords

  • lymphography
  • magnet resonance imaging
  • sentinel lymph node
  • thermoresponsive magnetic nanoparticle

ASJC Scopus subject areas

  • Surgery

Cite this

Sentinel node mapping with thermoresponsive magnetic nanoparticles in rats. / Hiraiwa, Kunihiko; Ueda, Masakazu; Takeuchi, Hiroya; Oyama, Takashi; Irino, Tomoyuki; Yoshikawa, Takahisa; Kondo, Akihiko; Kitagawa, Yuukou.

In: Journal of Surgical Research, Vol. 174, No. 1, 01.05.2012, p. 48-55.

Research output: Contribution to journalArticle

Hiraiwa, K, Ueda, M, Takeuchi, H, Oyama, T, Irino, T, Yoshikawa, T, Kondo, A & Kitagawa, Y 2012, 'Sentinel node mapping with thermoresponsive magnetic nanoparticles in rats', Journal of Surgical Research, vol. 174, no. 1, pp. 48-55. https://doi.org/10.1016/j.jss.2010.11.884
Hiraiwa K, Ueda M, Takeuchi H, Oyama T, Irino T, Yoshikawa T et al. Sentinel node mapping with thermoresponsive magnetic nanoparticles in rats. Journal of Surgical Research. 2012 May 1;174(1):48-55. https://doi.org/10.1016/j.jss.2010.11.884
Hiraiwa, Kunihiko ; Ueda, Masakazu ; Takeuchi, Hiroya ; Oyama, Takashi ; Irino, Tomoyuki ; Yoshikawa, Takahisa ; Kondo, Akihiko ; Kitagawa, Yuukou. / Sentinel node mapping with thermoresponsive magnetic nanoparticles in rats. In: Journal of Surgical Research. 2012 ; Vol. 174, No. 1. pp. 48-55.
@article{7db9b4248df442b1b7dcb397961b1ea7,
title = "Sentinel node mapping with thermoresponsive magnetic nanoparticles in rats",
abstract = "Background: In this study, we investigated the ability of magnetic resonance imaging (MRI) after interstitial administration of thermoresponsive magnetic nanoparticles to detect the sentinel lymph node (SLN). Materials and Methods: Postcontrast MRI scans were acquired following subcutaneous injection of thermoresponsive magnetic nanoparticles into the thoracic wall of rats. The signal-to-noise ratio of axillary lymph nodes was calculated to assess whether the SLN could be detected by MRI. In a second experiment, after injecting thermoresponsive magnetic nanoparticles, i.e., Therma-Max 36, Therma-Max 42, Therma-Max 55, and Ferridex, into the subserosa of the cecum of rats, the injection sites, the SLNs, and the distant lymph nodes were resected and examined histologically in order to determine which nanoparticles, if any, were specifically retained in the SLN. Results: MRI showed that the signal-to-noise ratio of axillary SLNs was significantly lower 24 h after injection of Therma-Max 42 than on the precontrast images (P < 0.05). Histologic evaluation revealed that Therma-Max 36 aggregated at body temperature and did not migrate to the SLN. Therma-Max 42, on the other hand, aggregated, and the particles became large enough to be retained in the SLNs. Therma-Max 55 and Ferridex did not aggregate, and they both migrated to the SLNs and the distant lymph nodes. Conclusions: The results of this study showed that thermoresponsive magnetic nanoparticles could be targeted to the SLN by adjusting the temperature at which they aggregate, and that they could be used as a contrast agent for SLN mapping by MRI.",
keywords = "lymphography, magnet resonance imaging, sentinel lymph node, thermoresponsive magnetic nanoparticle",
author = "Kunihiko Hiraiwa and Masakazu Ueda and Hiroya Takeuchi and Takashi Oyama and Tomoyuki Irino and Takahisa Yoshikawa and Akihiko Kondo and Yuukou Kitagawa",
year = "2012",
month = "5",
day = "1",
doi = "10.1016/j.jss.2010.11.884",
language = "English",
volume = "174",
pages = "48--55",
journal = "Journal of Surgical Research",
issn = "0022-4804",
publisher = "Academic Press Inc.",
number = "1",

}

TY - JOUR

T1 - Sentinel node mapping with thermoresponsive magnetic nanoparticles in rats

AU - Hiraiwa, Kunihiko

AU - Ueda, Masakazu

AU - Takeuchi, Hiroya

AU - Oyama, Takashi

AU - Irino, Tomoyuki

AU - Yoshikawa, Takahisa

AU - Kondo, Akihiko

AU - Kitagawa, Yuukou

PY - 2012/5/1

Y1 - 2012/5/1

N2 - Background: In this study, we investigated the ability of magnetic resonance imaging (MRI) after interstitial administration of thermoresponsive magnetic nanoparticles to detect the sentinel lymph node (SLN). Materials and Methods: Postcontrast MRI scans were acquired following subcutaneous injection of thermoresponsive magnetic nanoparticles into the thoracic wall of rats. The signal-to-noise ratio of axillary lymph nodes was calculated to assess whether the SLN could be detected by MRI. In a second experiment, after injecting thermoresponsive magnetic nanoparticles, i.e., Therma-Max 36, Therma-Max 42, Therma-Max 55, and Ferridex, into the subserosa of the cecum of rats, the injection sites, the SLNs, and the distant lymph nodes were resected and examined histologically in order to determine which nanoparticles, if any, were specifically retained in the SLN. Results: MRI showed that the signal-to-noise ratio of axillary SLNs was significantly lower 24 h after injection of Therma-Max 42 than on the precontrast images (P < 0.05). Histologic evaluation revealed that Therma-Max 36 aggregated at body temperature and did not migrate to the SLN. Therma-Max 42, on the other hand, aggregated, and the particles became large enough to be retained in the SLNs. Therma-Max 55 and Ferridex did not aggregate, and they both migrated to the SLNs and the distant lymph nodes. Conclusions: The results of this study showed that thermoresponsive magnetic nanoparticles could be targeted to the SLN by adjusting the temperature at which they aggregate, and that they could be used as a contrast agent for SLN mapping by MRI.

AB - Background: In this study, we investigated the ability of magnetic resonance imaging (MRI) after interstitial administration of thermoresponsive magnetic nanoparticles to detect the sentinel lymph node (SLN). Materials and Methods: Postcontrast MRI scans were acquired following subcutaneous injection of thermoresponsive magnetic nanoparticles into the thoracic wall of rats. The signal-to-noise ratio of axillary lymph nodes was calculated to assess whether the SLN could be detected by MRI. In a second experiment, after injecting thermoresponsive magnetic nanoparticles, i.e., Therma-Max 36, Therma-Max 42, Therma-Max 55, and Ferridex, into the subserosa of the cecum of rats, the injection sites, the SLNs, and the distant lymph nodes were resected and examined histologically in order to determine which nanoparticles, if any, were specifically retained in the SLN. Results: MRI showed that the signal-to-noise ratio of axillary SLNs was significantly lower 24 h after injection of Therma-Max 42 than on the precontrast images (P < 0.05). Histologic evaluation revealed that Therma-Max 36 aggregated at body temperature and did not migrate to the SLN. Therma-Max 42, on the other hand, aggregated, and the particles became large enough to be retained in the SLNs. Therma-Max 55 and Ferridex did not aggregate, and they both migrated to the SLNs and the distant lymph nodes. Conclusions: The results of this study showed that thermoresponsive magnetic nanoparticles could be targeted to the SLN by adjusting the temperature at which they aggregate, and that they could be used as a contrast agent for SLN mapping by MRI.

KW - lymphography

KW - magnet resonance imaging

KW - sentinel lymph node

KW - thermoresponsive magnetic nanoparticle

UR - http://www.scopus.com/inward/record.url?scp=84859111437&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84859111437&partnerID=8YFLogxK

U2 - 10.1016/j.jss.2010.11.884

DO - 10.1016/j.jss.2010.11.884

M3 - Article

VL - 174

SP - 48

EP - 55

JO - Journal of Surgical Research

JF - Journal of Surgical Research

SN - 0022-4804

IS - 1

ER -