Sloshing of a magnetic fluid in a laterally vibrated cylindrical container subject to a non-uniform vertical magnetic field was examined. Internal velocity profiles were measured using ultrasound Doppler velocimetry. The effect of the magnetic field on the resonant frequency of the fluid-container system was examined and the results were compared with theoretical results. The second and third peaks of the power spectra of velocity shifted to lower frequencies as the magnetic field was increased. It was observed that these derived frequency peaks were connected with swirling in the cylindrical container.

Original languageEnglish
Pages (from-to)197-203
Number of pages7
JournalExperiments in Fluids
Volume32
Issue number2
DOIs
Publication statusPublished - 2002 Feb

Fingerprint

liquid sloshing
Liquid sloshing
Magnetic fluids
containers
Containers
Magnetic fields
fluids
magnetic fields
swirling
Power spectrum
Velocity measurement
resonant frequencies
power spectra
Natural frequencies
velocity distribution
Ultrasonics
low frequencies
Fluids

ASJC Scopus subject areas

  • Mechanical Engineering
  • Fluid Flow and Transfer Processes
  • Mechanics of Materials
  • Computational Mechanics

Cite this

Sloshing behavior of a magnetic fluid in a cylindrical container. / Sawada, Tatsuo; Ohira, Y.; Houda, H.

In: Experiments in Fluids, Vol. 32, No. 2, 02.2002, p. 197-203.

Research output: Contribution to journalArticle

Sawada, Tatsuo ; Ohira, Y. ; Houda, H. / Sloshing behavior of a magnetic fluid in a cylindrical container. In: Experiments in Fluids. 2002 ; Vol. 32, No. 2. pp. 197-203.
@article{ed848c983bf04292af4350050ed8b9ec,
title = "Sloshing behavior of a magnetic fluid in a cylindrical container",
abstract = "Sloshing of a magnetic fluid in a laterally vibrated cylindrical container subject to a non-uniform vertical magnetic field was examined. Internal velocity profiles were measured using ultrasound Doppler velocimetry. The effect of the magnetic field on the resonant frequency of the fluid-container system was examined and the results were compared with theoretical results. The second and third peaks of the power spectra of velocity shifted to lower frequencies as the magnetic field was increased. It was observed that these derived frequency peaks were connected with swirling in the cylindrical container.",
author = "Tatsuo Sawada and Y. Ohira and H. Houda",
year = "2002",
month = "2",
doi = "10.1007/s003480100330",
language = "English",
volume = "32",
pages = "197--203",
journal = "Experiments in Fluids",
issn = "0723-4864",
publisher = "Springer Verlag",
number = "2",

}

TY - JOUR

T1 - Sloshing behavior of a magnetic fluid in a cylindrical container

AU - Sawada, Tatsuo

AU - Ohira, Y.

AU - Houda, H.

PY - 2002/2

Y1 - 2002/2

N2 - Sloshing of a magnetic fluid in a laterally vibrated cylindrical container subject to a non-uniform vertical magnetic field was examined. Internal velocity profiles were measured using ultrasound Doppler velocimetry. The effect of the magnetic field on the resonant frequency of the fluid-container system was examined and the results were compared with theoretical results. The second and third peaks of the power spectra of velocity shifted to lower frequencies as the magnetic field was increased. It was observed that these derived frequency peaks were connected with swirling in the cylindrical container.

AB - Sloshing of a magnetic fluid in a laterally vibrated cylindrical container subject to a non-uniform vertical magnetic field was examined. Internal velocity profiles were measured using ultrasound Doppler velocimetry. The effect of the magnetic field on the resonant frequency of the fluid-container system was examined and the results were compared with theoretical results. The second and third peaks of the power spectra of velocity shifted to lower frequencies as the magnetic field was increased. It was observed that these derived frequency peaks were connected with swirling in the cylindrical container.

UR - http://www.scopus.com/inward/record.url?scp=14844309151&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=14844309151&partnerID=8YFLogxK

U2 - 10.1007/s003480100330

DO - 10.1007/s003480100330

M3 - Article

VL - 32

SP - 197

EP - 203

JO - Experiments in Fluids

JF - Experiments in Fluids

SN - 0723-4864

IS - 2

ER -