TY - JOUR
T1 - Streamlining the learning process for TAVI
T2 - Insight from a comparative analysis of the OCEAN-TAVI and the massy registries
AU - Inohara, Taku
AU - Hayashida, Kentaro
AU - Watanabe, Yusuke
AU - Yamamoto, Masanori
AU - Takagi, Kensuke
AU - Yashima, Fumiaki
AU - Arai, Takahide
AU - Shimizu, Hideyuki
AU - Chevalier, Bernard
AU - Lefèvre, Thierry
AU - Fukuda, Keiichi
AU - Morice, Marie Claude
N1 - Publisher Copyright:
© 2015 Wiley Periodicals, Inc.
PY - 2016/4/1
Y1 - 2016/4/1
N2 - Backgrounds To facilitate the learning process of transcatheter aortic valve implantation (TAVI) in Japan, unique supporting systems (e.g., on-site proctor and web-based screening systems) have been developed. Nevertheless, little is known about real-world clinical outcomes after TAVI in Japan compared with their European counterparts. Methods From the optimized catheter valvular intervention (OCEAN-TAVI, Japan) and the Institut Cardiovasculaire Paris Sud (Massy, France) registries, we evaluated a total of 134 and 178 patients, respectively, who underwent transfemoral TAVI during the same time period. Results Among the French cohort, about half of the patients (N = 81, 45.5%) were treated with the Edwards SAPIEN XT. Body surface area was significantly smaller in the Japanese cohort, although operative risks for both cohorts were almost the same. A greater percentage of patients in the Japanese cohort were implanted with 23 mm valves compared with the French cohort (73.1% vs. 23.0%, P < 0.001), reflecting the smaller annulus diameter (21.8 ± 1.6 vs. 23.8 ± 2.4 mm, P < 0.001). All-cause 30-day mortality (0% vs. 0.6%, P = 1.000) and 30-day combined safety endpoint based on the Valve Academic Research Consortium 2 (VARC2) criteria (9.7% vs. 11.2%, P = 0.713) were similar when limiting the analysis to patients treated with the Edwards SAPIEN XT. Conclusions Despite the unfavorable aortic anatomy of the Japanese patients, their clinical outcomes after transfemoral TAVI were excellent with the same degree of safety as in an experienced European institute. This minimized learning process achieved the use of unique support systems.
AB - Backgrounds To facilitate the learning process of transcatheter aortic valve implantation (TAVI) in Japan, unique supporting systems (e.g., on-site proctor and web-based screening systems) have been developed. Nevertheless, little is known about real-world clinical outcomes after TAVI in Japan compared with their European counterparts. Methods From the optimized catheter valvular intervention (OCEAN-TAVI, Japan) and the Institut Cardiovasculaire Paris Sud (Massy, France) registries, we evaluated a total of 134 and 178 patients, respectively, who underwent transfemoral TAVI during the same time period. Results Among the French cohort, about half of the patients (N = 81, 45.5%) were treated with the Edwards SAPIEN XT. Body surface area was significantly smaller in the Japanese cohort, although operative risks for both cohorts were almost the same. A greater percentage of patients in the Japanese cohort were implanted with 23 mm valves compared with the French cohort (73.1% vs. 23.0%, P < 0.001), reflecting the smaller annulus diameter (21.8 ± 1.6 vs. 23.8 ± 2.4 mm, P < 0.001). All-cause 30-day mortality (0% vs. 0.6%, P = 1.000) and 30-day combined safety endpoint based on the Valve Academic Research Consortium 2 (VARC2) criteria (9.7% vs. 11.2%, P = 0.713) were similar when limiting the analysis to patients treated with the Edwards SAPIEN XT. Conclusions Despite the unfavorable aortic anatomy of the Japanese patients, their clinical outcomes after transfemoral TAVI were excellent with the same degree of safety as in an experienced European institute. This minimized learning process achieved the use of unique support systems.
KW - ethnicity
KW - outcome
KW - transcatheter aortic valve implantation
UR - http://www.scopus.com/inward/record.url?scp=84963815682&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84963815682&partnerID=8YFLogxK
U2 - 10.1002/ccd.26266
DO - 10.1002/ccd.26266
M3 - Article
C2 - 26489980
AN - SCOPUS:84963815682
SN - 1522-1946
VL - 87
SP - 963
EP - 970
JO - Catheterization and Cardiovascular Interventions
JF - Catheterization and Cardiovascular Interventions
IS - 5
ER -