Study on a new index of fetal respiratory function: a novel optical analysis of the amniotic fluid by the vacuum-dried infrared attenuated total reflection (ATR) method.

H. Kobayashi, M. Kobayashi, Tsunenori Arai, M. Kikuchi, H. Okino

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

For the purpose of detecting fetal pulmonary maturity with real-time convenience but reliable accuracy, infrared spectrophotometry of amniotic fluid lipids was introduced using our newly developed optical device. The peak areas at the wave number of 1740 cm-1 on the infrared spectra (called "PA1740") were measured in 29 specimens sampled from 29 pregnant women, and compared with the Lecithin/Sphingomyelin (L/S) ratio of the same samples. Statistical analysis revealed that the PA1740 was almost as reliable as the L/S ratio, and these indices illustrated pulmonary immaturity in cases with a PA1740 less than 0.9 and an L/S ratio less than 2.0. PA1740 is absolutely independent of the effect on the concentration of lecithin in the amniotic fluid because of a combination of the vacuum-drying process and the absorbance correction, and can be completed in less than 20 minutes from sampling of the amniotic fluid by a very simple manipulation. In conclusion, the new index, PA1740, will be a more practical method for prediction of the fetal pulmonary maturity than methods such as the well known L/S ratio.

Original languageEnglish
Pages (from-to)425-433
Number of pages9
JournalTokai Journal of Experimental and Clinical Medicine
Volume15
Issue number6
Publication statusPublished - 1990 Nov
Externally publishedYes

Fingerprint

Lecithins
Amniotic Fluid
Vacuum
Sphingomyelins
Lung
Infrared Spectrophotometry
Optical Devices
Pregnant Women
Lipids

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Study on a new index of fetal respiratory function : a novel optical analysis of the amniotic fluid by the vacuum-dried infrared attenuated total reflection (ATR) method. / Kobayashi, H.; Kobayashi, M.; Arai, Tsunenori; Kikuchi, M.; Okino, H.

In: Tokai Journal of Experimental and Clinical Medicine, Vol. 15, No. 6, 11.1990, p. 425-433.

Research output: Contribution to journalArticle

@article{18f7443a54f24a648a2f242bbc86d877,
title = "Study on a new index of fetal respiratory function: a novel optical analysis of the amniotic fluid by the vacuum-dried infrared attenuated total reflection (ATR) method.",
abstract = "For the purpose of detecting fetal pulmonary maturity with real-time convenience but reliable accuracy, infrared spectrophotometry of amniotic fluid lipids was introduced using our newly developed optical device. The peak areas at the wave number of 1740 cm-1 on the infrared spectra (called {"}PA1740{"}) were measured in 29 specimens sampled from 29 pregnant women, and compared with the Lecithin/Sphingomyelin (L/S) ratio of the same samples. Statistical analysis revealed that the PA1740 was almost as reliable as the L/S ratio, and these indices illustrated pulmonary immaturity in cases with a PA1740 less than 0.9 and an L/S ratio less than 2.0. PA1740 is absolutely independent of the effect on the concentration of lecithin in the amniotic fluid because of a combination of the vacuum-drying process and the absorbance correction, and can be completed in less than 20 minutes from sampling of the amniotic fluid by a very simple manipulation. In conclusion, the new index, PA1740, will be a more practical method for prediction of the fetal pulmonary maturity than methods such as the well known L/S ratio.",
author = "H. Kobayashi and M. Kobayashi and Tsunenori Arai and M. Kikuchi and H. Okino",
year = "1990",
month = "11",
language = "English",
volume = "15",
pages = "425--433",
journal = "Tokai Journal of Experimental and Clinical Medicine",
issn = "0385-0005",
publisher = "Tokai Medical Association",
number = "6",

}

TY - JOUR

T1 - Study on a new index of fetal respiratory function

T2 - a novel optical analysis of the amniotic fluid by the vacuum-dried infrared attenuated total reflection (ATR) method.

AU - Kobayashi, H.

AU - Kobayashi, M.

AU - Arai, Tsunenori

AU - Kikuchi, M.

AU - Okino, H.

PY - 1990/11

Y1 - 1990/11

N2 - For the purpose of detecting fetal pulmonary maturity with real-time convenience but reliable accuracy, infrared spectrophotometry of amniotic fluid lipids was introduced using our newly developed optical device. The peak areas at the wave number of 1740 cm-1 on the infrared spectra (called "PA1740") were measured in 29 specimens sampled from 29 pregnant women, and compared with the Lecithin/Sphingomyelin (L/S) ratio of the same samples. Statistical analysis revealed that the PA1740 was almost as reliable as the L/S ratio, and these indices illustrated pulmonary immaturity in cases with a PA1740 less than 0.9 and an L/S ratio less than 2.0. PA1740 is absolutely independent of the effect on the concentration of lecithin in the amniotic fluid because of a combination of the vacuum-drying process and the absorbance correction, and can be completed in less than 20 minutes from sampling of the amniotic fluid by a very simple manipulation. In conclusion, the new index, PA1740, will be a more practical method for prediction of the fetal pulmonary maturity than methods such as the well known L/S ratio.

AB - For the purpose of detecting fetal pulmonary maturity with real-time convenience but reliable accuracy, infrared spectrophotometry of amniotic fluid lipids was introduced using our newly developed optical device. The peak areas at the wave number of 1740 cm-1 on the infrared spectra (called "PA1740") were measured in 29 specimens sampled from 29 pregnant women, and compared with the Lecithin/Sphingomyelin (L/S) ratio of the same samples. Statistical analysis revealed that the PA1740 was almost as reliable as the L/S ratio, and these indices illustrated pulmonary immaturity in cases with a PA1740 less than 0.9 and an L/S ratio less than 2.0. PA1740 is absolutely independent of the effect on the concentration of lecithin in the amniotic fluid because of a combination of the vacuum-drying process and the absorbance correction, and can be completed in less than 20 minutes from sampling of the amniotic fluid by a very simple manipulation. In conclusion, the new index, PA1740, will be a more practical method for prediction of the fetal pulmonary maturity than methods such as the well known L/S ratio.

UR - http://www.scopus.com/inward/record.url?scp=0025519104&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0025519104&partnerID=8YFLogxK

M3 - Article

C2 - 2131649

AN - SCOPUS:0025519104

VL - 15

SP - 425

EP - 433

JO - Tokai Journal of Experimental and Clinical Medicine

JF - Tokai Journal of Experimental and Clinical Medicine

SN - 0385-0005

IS - 6

ER -