Purpose: To equalize the quality of radiation therapy in Japan by supporting quality control of radiation treatment planning system. Methods: Center for Cancer Control and Information Service in National Cancer Center supports the QA‐QC of the cancer core hospitals in Japan as a third‐party evaluation agency. Recently, a program for assessing the quality of treatment planning system (TPS) began as a part of our QA‐QC supporting activities. In this program, a questionnaire about TPS was sent to 45 prefectural cancer core hospitals in Japan. The object of this questionnaire is to assess the proper commissioning, implement and applications of TPSs. The contents of the questionnaire are as follows; 1) calculate MUs which deliver 1000 cGy to the point of SSD = 100 cm, 10 cm depth with field sizes ranging from 5×5 to 30 × 30 cm2, and obtain doses at several depths for the calculated MUs, 2) calculate MUs which deliver 1000 cGy to the point of SSD = 100 cm, 10 cm depth for wedge fields whose angles are from 15 to 60 degrees, and obtain doses at several depths with the MUs, 3) calculate MU which deliver 1000 cGy to the point of STD = 100 cm, 10 cm depth with 10×10 cm2 field size and obtain doses at several depths with the MU. Results: In this program, 179 beam data from 44 facilities were collected. Data were compared in terms of dose per MU, output factor, wedge factor and TMR. It was found that 90% of the data agreed within 2%. Conclusions: The quality of the treatment planning system was investigated through the questionnaire including the information of essential beam data. We compared 179 beam data in TPSs sent from 44 facilities and 90% of the data showed good agreement.

Original languageEnglish
Number of pages1
JournalMedical Physics
Volume39
Issue number6
DOIs
Publication statusPublished - 2012 Jan 1
Externally publishedYes

Fingerprint

Japan
Silver Sulfadiazine
Cancer Care Facilities
Information Services
Therapeutics
Sexually Transmitted Diseases
Quality Control
Neoplasms
Radiotherapy
Radiation
Surveys and Questionnaires

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

SU‐E‐T‐216 : TPS QC Supporting Program by a Third‐Party Evaluation Agency in Japan. / Fukata, Kyohei; Minemura, T.; Kurokawa, C.; Miyagishi, T.; Itami, J.

In: Medical Physics, Vol. 39, No. 6, 01.01.2012.

Research output: Contribution to journalArticle

Fukata, Kyohei ; Minemura, T. ; Kurokawa, C. ; Miyagishi, T. ; Itami, J. / SU‐E‐T‐216 : TPS QC Supporting Program by a Third‐Party Evaluation Agency in Japan. In: Medical Physics. 2012 ; Vol. 39, No. 6.
@article{997a8d421b4b4e7b8bafeaa37fe8cded,
title = "SU‐E‐T‐216: TPS QC Supporting Program by a Third‐Party Evaluation Agency in Japan",
abstract = "Purpose: To equalize the quality of radiation therapy in Japan by supporting quality control of radiation treatment planning system. Methods: Center for Cancer Control and Information Service in National Cancer Center supports the QA‐QC of the cancer core hospitals in Japan as a third‐party evaluation agency. Recently, a program for assessing the quality of treatment planning system (TPS) began as a part of our QA‐QC supporting activities. In this program, a questionnaire about TPS was sent to 45 prefectural cancer core hospitals in Japan. The object of this questionnaire is to assess the proper commissioning, implement and applications of TPSs. The contents of the questionnaire are as follows; 1) calculate MUs which deliver 1000 cGy to the point of SSD = 100 cm, 10 cm depth with field sizes ranging from 5×5 to 30 × 30 cm2, and obtain doses at several depths for the calculated MUs, 2) calculate MUs which deliver 1000 cGy to the point of SSD = 100 cm, 10 cm depth for wedge fields whose angles are from 15 to 60 degrees, and obtain doses at several depths with the MUs, 3) calculate MU which deliver 1000 cGy to the point of STD = 100 cm, 10 cm depth with 10×10 cm2 field size and obtain doses at several depths with the MU. Results: In this program, 179 beam data from 44 facilities were collected. Data were compared in terms of dose per MU, output factor, wedge factor and TMR. It was found that 90{\%} of the data agreed within 2{\%}. Conclusions: The quality of the treatment planning system was investigated through the questionnaire including the information of essential beam data. We compared 179 beam data in TPSs sent from 44 facilities and 90{\%} of the data showed good agreement.",
author = "Kyohei Fukata and T. Minemura and C. Kurokawa and T. Miyagishi and J. Itami",
year = "2012",
month = "1",
day = "1",
doi = "10.1118/1.4735277",
language = "English",
volume = "39",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

TY - JOUR

T1 - SU‐E‐T‐216

T2 - TPS QC Supporting Program by a Third‐Party Evaluation Agency in Japan

AU - Fukata, Kyohei

AU - Minemura, T.

AU - Kurokawa, C.

AU - Miyagishi, T.

AU - Itami, J.

PY - 2012/1/1

Y1 - 2012/1/1

N2 - Purpose: To equalize the quality of radiation therapy in Japan by supporting quality control of radiation treatment planning system. Methods: Center for Cancer Control and Information Service in National Cancer Center supports the QA‐QC of the cancer core hospitals in Japan as a third‐party evaluation agency. Recently, a program for assessing the quality of treatment planning system (TPS) began as a part of our QA‐QC supporting activities. In this program, a questionnaire about TPS was sent to 45 prefectural cancer core hospitals in Japan. The object of this questionnaire is to assess the proper commissioning, implement and applications of TPSs. The contents of the questionnaire are as follows; 1) calculate MUs which deliver 1000 cGy to the point of SSD = 100 cm, 10 cm depth with field sizes ranging from 5×5 to 30 × 30 cm2, and obtain doses at several depths for the calculated MUs, 2) calculate MUs which deliver 1000 cGy to the point of SSD = 100 cm, 10 cm depth for wedge fields whose angles are from 15 to 60 degrees, and obtain doses at several depths with the MUs, 3) calculate MU which deliver 1000 cGy to the point of STD = 100 cm, 10 cm depth with 10×10 cm2 field size and obtain doses at several depths with the MU. Results: In this program, 179 beam data from 44 facilities were collected. Data were compared in terms of dose per MU, output factor, wedge factor and TMR. It was found that 90% of the data agreed within 2%. Conclusions: The quality of the treatment planning system was investigated through the questionnaire including the information of essential beam data. We compared 179 beam data in TPSs sent from 44 facilities and 90% of the data showed good agreement.

AB - Purpose: To equalize the quality of radiation therapy in Japan by supporting quality control of radiation treatment planning system. Methods: Center for Cancer Control and Information Service in National Cancer Center supports the QA‐QC of the cancer core hospitals in Japan as a third‐party evaluation agency. Recently, a program for assessing the quality of treatment planning system (TPS) began as a part of our QA‐QC supporting activities. In this program, a questionnaire about TPS was sent to 45 prefectural cancer core hospitals in Japan. The object of this questionnaire is to assess the proper commissioning, implement and applications of TPSs. The contents of the questionnaire are as follows; 1) calculate MUs which deliver 1000 cGy to the point of SSD = 100 cm, 10 cm depth with field sizes ranging from 5×5 to 30 × 30 cm2, and obtain doses at several depths for the calculated MUs, 2) calculate MUs which deliver 1000 cGy to the point of SSD = 100 cm, 10 cm depth for wedge fields whose angles are from 15 to 60 degrees, and obtain doses at several depths with the MUs, 3) calculate MU which deliver 1000 cGy to the point of STD = 100 cm, 10 cm depth with 10×10 cm2 field size and obtain doses at several depths with the MU. Results: In this program, 179 beam data from 44 facilities were collected. Data were compared in terms of dose per MU, output factor, wedge factor and TMR. It was found that 90% of the data agreed within 2%. Conclusions: The quality of the treatment planning system was investigated through the questionnaire including the information of essential beam data. We compared 179 beam data in TPSs sent from 44 facilities and 90% of the data showed good agreement.

UR - http://www.scopus.com/inward/record.url?scp=85024799662&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85024799662&partnerID=8YFLogxK

U2 - 10.1118/1.4735277

DO - 10.1118/1.4735277

M3 - Article

VL - 39

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -