Surgical punctal occlusion with a high heat-energy releasing cautery device for severe dry eye with recurrent punctal plug extrusion

Emii Ohba, Murat Dogru, Eri Hosaka, Asako Yamazaki, Rie Asaga, Yukako Tatematsu, Yoko Ogawa, Kazuo Tsubota, Eiki Goto

Research output: Contribution to journalArticle

18 Citations (Scopus)

Abstract

• Purpose: To report the rate of recanalization and the efficacy of punctal occlusion surgery with a high heat-energy-releasing cautery device in patients with severe dry eye disease and recurrent punctal plug extrusion. • Design: Prospective, interventional case series. • Methods: Seventy puncta from 44 eyes of 28 dry eye patients underwent punctal occlusion with thermal cautery. All patients had a history of recurrent punctal plug extrusion. A high heat-energy-releasing thermal cautery device (Optemp II V; Alcon Japan) was used for punctal occlusion surgery. Symptom scores, best-corrected visual acuity, fluorescein staining score, rose bengal staining score, tear film break-up time, and Schirmer test values were compared before and 3 months after the surgery. Rate of punctal recanalization also was examined. • Results: Three months after surgical cauterization, symptom score decreased from 3.9 ± 0.23 to 0.56 ± 0.84 (P < .0001). Logarithm of the minimal angle of resolution best-corrected visual acuity improved from 0.11 ± 0.30 to 0.013 ± 0.22 (P = .003). Fluorescein staining score, rose bengal staining score, tear film break-up time, and the Schirmer test value also improved significantly after the surgery. Only 1 of 70 puncta recanalized after thermal cauterization (1.4%). • Conclusions: Punctal occlusion with the high heat-energy-releasing cautery device not only was associated with a low recanalization rate, but also with improvements in ocular surface wetness and better visual acuity.

Original languageEnglish
JournalAmerican Journal of Ophthalmology
Volume151
Issue number3
DOIs
Publication statusPublished - 2011 Mar

Fingerprint

Cautery
Hot Temperature
Equipment and Supplies
Staining and Labeling
Visual Acuity
Rose Bengal
Fluorescein
Tears
Eye Diseases
Punctal Plugs
Japan

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Surgical punctal occlusion with a high heat-energy releasing cautery device for severe dry eye with recurrent punctal plug extrusion. / Ohba, Emii; Dogru, Murat; Hosaka, Eri; Yamazaki, Asako; Asaga, Rie; Tatematsu, Yukako; Ogawa, Yoko; Tsubota, Kazuo; Goto, Eiki.

In: American Journal of Ophthalmology, Vol. 151, No. 3, 03.2011.

Research output: Contribution to journalArticle

Ohba, Emii ; Dogru, Murat ; Hosaka, Eri ; Yamazaki, Asako ; Asaga, Rie ; Tatematsu, Yukako ; Ogawa, Yoko ; Tsubota, Kazuo ; Goto, Eiki. / Surgical punctal occlusion with a high heat-energy releasing cautery device for severe dry eye with recurrent punctal plug extrusion. In: American Journal of Ophthalmology. 2011 ; Vol. 151, No. 3.
@article{55f6fcd5895d44beb36e7bbc63f798a3,
title = "Surgical punctal occlusion with a high heat-energy releasing cautery device for severe dry eye with recurrent punctal plug extrusion",
abstract = "• Purpose: To report the rate of recanalization and the efficacy of punctal occlusion surgery with a high heat-energy-releasing cautery device in patients with severe dry eye disease and recurrent punctal plug extrusion. • Design: Prospective, interventional case series. • Methods: Seventy puncta from 44 eyes of 28 dry eye patients underwent punctal occlusion with thermal cautery. All patients had a history of recurrent punctal plug extrusion. A high heat-energy-releasing thermal cautery device (Optemp II V; Alcon Japan) was used for punctal occlusion surgery. Symptom scores, best-corrected visual acuity, fluorescein staining score, rose bengal staining score, tear film break-up time, and Schirmer test values were compared before and 3 months after the surgery. Rate of punctal recanalization also was examined. • Results: Three months after surgical cauterization, symptom score decreased from 3.9 ± 0.23 to 0.56 ± 0.84 (P < .0001). Logarithm of the minimal angle of resolution best-corrected visual acuity improved from 0.11 ± 0.30 to 0.013 ± 0.22 (P = .003). Fluorescein staining score, rose bengal staining score, tear film break-up time, and the Schirmer test value also improved significantly after the surgery. Only 1 of 70 puncta recanalized after thermal cauterization (1.4{\%}). • Conclusions: Punctal occlusion with the high heat-energy-releasing cautery device not only was associated with a low recanalization rate, but also with improvements in ocular surface wetness and better visual acuity.",
author = "Emii Ohba and Murat Dogru and Eri Hosaka and Asako Yamazaki and Rie Asaga and Yukako Tatematsu and Yoko Ogawa and Kazuo Tsubota and Eiki Goto",
year = "2011",
month = "3",
doi = "10.1016/j.ajo.2010.08.045",
language = "English",
volume = "151",
journal = "American Journal of Ophthalmology",
issn = "0002-9394",
publisher = "Elsevier USA",
number = "3",

}

TY - JOUR

T1 - Surgical punctal occlusion with a high heat-energy releasing cautery device for severe dry eye with recurrent punctal plug extrusion

AU - Ohba, Emii

AU - Dogru, Murat

AU - Hosaka, Eri

AU - Yamazaki, Asako

AU - Asaga, Rie

AU - Tatematsu, Yukako

AU - Ogawa, Yoko

AU - Tsubota, Kazuo

AU - Goto, Eiki

PY - 2011/3

Y1 - 2011/3

N2 - • Purpose: To report the rate of recanalization and the efficacy of punctal occlusion surgery with a high heat-energy-releasing cautery device in patients with severe dry eye disease and recurrent punctal plug extrusion. • Design: Prospective, interventional case series. • Methods: Seventy puncta from 44 eyes of 28 dry eye patients underwent punctal occlusion with thermal cautery. All patients had a history of recurrent punctal plug extrusion. A high heat-energy-releasing thermal cautery device (Optemp II V; Alcon Japan) was used for punctal occlusion surgery. Symptom scores, best-corrected visual acuity, fluorescein staining score, rose bengal staining score, tear film break-up time, and Schirmer test values were compared before and 3 months after the surgery. Rate of punctal recanalization also was examined. • Results: Three months after surgical cauterization, symptom score decreased from 3.9 ± 0.23 to 0.56 ± 0.84 (P < .0001). Logarithm of the minimal angle of resolution best-corrected visual acuity improved from 0.11 ± 0.30 to 0.013 ± 0.22 (P = .003). Fluorescein staining score, rose bengal staining score, tear film break-up time, and the Schirmer test value also improved significantly after the surgery. Only 1 of 70 puncta recanalized after thermal cauterization (1.4%). • Conclusions: Punctal occlusion with the high heat-energy-releasing cautery device not only was associated with a low recanalization rate, but also with improvements in ocular surface wetness and better visual acuity.

AB - • Purpose: To report the rate of recanalization and the efficacy of punctal occlusion surgery with a high heat-energy-releasing cautery device in patients with severe dry eye disease and recurrent punctal plug extrusion. • Design: Prospective, interventional case series. • Methods: Seventy puncta from 44 eyes of 28 dry eye patients underwent punctal occlusion with thermal cautery. All patients had a history of recurrent punctal plug extrusion. A high heat-energy-releasing thermal cautery device (Optemp II V; Alcon Japan) was used for punctal occlusion surgery. Symptom scores, best-corrected visual acuity, fluorescein staining score, rose bengal staining score, tear film break-up time, and Schirmer test values were compared before and 3 months after the surgery. Rate of punctal recanalization also was examined. • Results: Three months after surgical cauterization, symptom score decreased from 3.9 ± 0.23 to 0.56 ± 0.84 (P < .0001). Logarithm of the minimal angle of resolution best-corrected visual acuity improved from 0.11 ± 0.30 to 0.013 ± 0.22 (P = .003). Fluorescein staining score, rose bengal staining score, tear film break-up time, and the Schirmer test value also improved significantly after the surgery. Only 1 of 70 puncta recanalized after thermal cauterization (1.4%). • Conclusions: Punctal occlusion with the high heat-energy-releasing cautery device not only was associated with a low recanalization rate, but also with improvements in ocular surface wetness and better visual acuity.

UR - http://www.scopus.com/inward/record.url?scp=79951811073&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79951811073&partnerID=8YFLogxK

U2 - 10.1016/j.ajo.2010.08.045

DO - 10.1016/j.ajo.2010.08.045

M3 - Article

VL - 151

JO - American Journal of Ophthalmology

JF - American Journal of Ophthalmology

SN - 0002-9394

IS - 3

ER -