The efficacy of transcorneal electrical stimulation for the treatment of primary open-angle glaucoma

A pilot study

Yuka Ota, Naoki Ozeki, Kenya Yuki, Daisuke Shiba, Itaru Kimura, Kazushige Tsunoda, Kei Shinoda, Hisao Ohde, Kazuo Tsubota

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

The aim of this study was to evaluate the effects of transcorneal electrical stimulation in subjects with primary open-angle glaucoma. Five eyes of four male subjects with primary open-angle glaucoma (average age: 52.25 ± 14.68 years) were enrolled. The subjects underwent transcorneal electrical stimulation every 3 months according to the following procedure. A Dawson-Trick-Litzkow electrode was placed on the cornea, and biphasic electric current pulses (10 ms, 20 Hz) were delivered using a stimulator (BPG-1, BAK Electronics) and a stimulus isolation unit (BSI-2). A current that evoked a phosphene that the subject perceived in the whole visual area was delivered continuously for 30 min. Humphrey visual field testing was performed after every third transcorneal electrical stimulation treatment. Changes in mean deviation (MD) values were evaluated with a linear regression model. Transcorneal electrical stimulation was performed 18.2 ± 9.4 times over a period of 49.8 ± 23.0 months. The average pretranscorneal electrical stimulation intraocular pressure, best corrected visual acuity, and MD values were 11.8 ± 1.79 mmHg, 0.14 ± 0.19 (logMAR) and −17.28 ± 6.24 dB, respectively. No significant differences were observed in intraocular pressure before and after transcorneal electrical stimulation. However, there was a significant positive linear relationship between changes in MD values and the number of transcorneal electrical stimulation treatments (R2 = 0.176, P = 0.005, Spearman correlation R = 0.294, P = 0.008). Transcorneal electrical stimulation treatment may improve glaucomatous visual field defects in subjects with primary open-angle glaucoma. Large-scale studies are necessary to confirm these preliminary findings.

Original languageEnglish
Pages (from-to)45-53
Number of pages9
JournalKeio Journal of Medicine
Volume67
Issue number3
DOIs
Publication statusPublished - 2018 Jan 1

Fingerprint

Electric Stimulation
Therapeutics
Visual Fields
Intraocular Pressure
Linear Models
Phosphenes
Primary Open Angle Glaucoma
Cornea
Visual Acuity
Electrodes

Keywords

  • Neuroprotection
  • Primary open-angle glaucoma
  • Transcorneal electrical stimulation
  • Visual field

ASJC Scopus subject areas

  • Medicine(all)

Cite this

The efficacy of transcorneal electrical stimulation for the treatment of primary open-angle glaucoma : A pilot study. / Ota, Yuka; Ozeki, Naoki; Yuki, Kenya; Shiba, Daisuke; Kimura, Itaru; Tsunoda, Kazushige; Shinoda, Kei; Ohde, Hisao; Tsubota, Kazuo.

In: Keio Journal of Medicine, Vol. 67, No. 3, 01.01.2018, p. 45-53.

Research output: Contribution to journalArticle

Ota, Yuka ; Ozeki, Naoki ; Yuki, Kenya ; Shiba, Daisuke ; Kimura, Itaru ; Tsunoda, Kazushige ; Shinoda, Kei ; Ohde, Hisao ; Tsubota, Kazuo. / The efficacy of transcorneal electrical stimulation for the treatment of primary open-angle glaucoma : A pilot study. In: Keio Journal of Medicine. 2018 ; Vol. 67, No. 3. pp. 45-53.
@article{18ee193f5f0e4e7191af9f6772f3e679,
title = "The efficacy of transcorneal electrical stimulation for the treatment of primary open-angle glaucoma: A pilot study",
abstract = "The aim of this study was to evaluate the effects of transcorneal electrical stimulation in subjects with primary open-angle glaucoma. Five eyes of four male subjects with primary open-angle glaucoma (average age: 52.25 ± 14.68 years) were enrolled. The subjects underwent transcorneal electrical stimulation every 3 months according to the following procedure. A Dawson-Trick-Litzkow electrode was placed on the cornea, and biphasic electric current pulses (10 ms, 20 Hz) were delivered using a stimulator (BPG-1, BAK Electronics) and a stimulus isolation unit (BSI-2). A current that evoked a phosphene that the subject perceived in the whole visual area was delivered continuously for 30 min. Humphrey visual field testing was performed after every third transcorneal electrical stimulation treatment. Changes in mean deviation (MD) values were evaluated with a linear regression model. Transcorneal electrical stimulation was performed 18.2 ± 9.4 times over a period of 49.8 ± 23.0 months. The average pretranscorneal electrical stimulation intraocular pressure, best corrected visual acuity, and MD values were 11.8 ± 1.79 mmHg, 0.14 ± 0.19 (logMAR) and −17.28 ± 6.24 dB, respectively. No significant differences were observed in intraocular pressure before and after transcorneal electrical stimulation. However, there was a significant positive linear relationship between changes in MD values and the number of transcorneal electrical stimulation treatments (R2 = 0.176, P = 0.005, Spearman correlation R = 0.294, P = 0.008). Transcorneal electrical stimulation treatment may improve glaucomatous visual field defects in subjects with primary open-angle glaucoma. Large-scale studies are necessary to confirm these preliminary findings.",
keywords = "Neuroprotection, Primary open-angle glaucoma, Transcorneal electrical stimulation, Visual field",
author = "Yuka Ota and Naoki Ozeki and Kenya Yuki and Daisuke Shiba and Itaru Kimura and Kazushige Tsunoda and Kei Shinoda and Hisao Ohde and Kazuo Tsubota",
year = "2018",
month = "1",
day = "1",
doi = "10.2302/kjm.2017-0015-OA",
language = "English",
volume = "67",
pages = "45--53",
journal = "Keio Journal of Medicine",
issn = "0022-9717",
publisher = "Keio University School of Medicine",
number = "3",

}

TY - JOUR

T1 - The efficacy of transcorneal electrical stimulation for the treatment of primary open-angle glaucoma

T2 - A pilot study

AU - Ota, Yuka

AU - Ozeki, Naoki

AU - Yuki, Kenya

AU - Shiba, Daisuke

AU - Kimura, Itaru

AU - Tsunoda, Kazushige

AU - Shinoda, Kei

AU - Ohde, Hisao

AU - Tsubota, Kazuo

PY - 2018/1/1

Y1 - 2018/1/1

N2 - The aim of this study was to evaluate the effects of transcorneal electrical stimulation in subjects with primary open-angle glaucoma. Five eyes of four male subjects with primary open-angle glaucoma (average age: 52.25 ± 14.68 years) were enrolled. The subjects underwent transcorneal electrical stimulation every 3 months according to the following procedure. A Dawson-Trick-Litzkow electrode was placed on the cornea, and biphasic electric current pulses (10 ms, 20 Hz) were delivered using a stimulator (BPG-1, BAK Electronics) and a stimulus isolation unit (BSI-2). A current that evoked a phosphene that the subject perceived in the whole visual area was delivered continuously for 30 min. Humphrey visual field testing was performed after every third transcorneal electrical stimulation treatment. Changes in mean deviation (MD) values were evaluated with a linear regression model. Transcorneal electrical stimulation was performed 18.2 ± 9.4 times over a period of 49.8 ± 23.0 months. The average pretranscorneal electrical stimulation intraocular pressure, best corrected visual acuity, and MD values were 11.8 ± 1.79 mmHg, 0.14 ± 0.19 (logMAR) and −17.28 ± 6.24 dB, respectively. No significant differences were observed in intraocular pressure before and after transcorneal electrical stimulation. However, there was a significant positive linear relationship between changes in MD values and the number of transcorneal electrical stimulation treatments (R2 = 0.176, P = 0.005, Spearman correlation R = 0.294, P = 0.008). Transcorneal electrical stimulation treatment may improve glaucomatous visual field defects in subjects with primary open-angle glaucoma. Large-scale studies are necessary to confirm these preliminary findings.

AB - The aim of this study was to evaluate the effects of transcorneal electrical stimulation in subjects with primary open-angle glaucoma. Five eyes of four male subjects with primary open-angle glaucoma (average age: 52.25 ± 14.68 years) were enrolled. The subjects underwent transcorneal electrical stimulation every 3 months according to the following procedure. A Dawson-Trick-Litzkow electrode was placed on the cornea, and biphasic electric current pulses (10 ms, 20 Hz) were delivered using a stimulator (BPG-1, BAK Electronics) and a stimulus isolation unit (BSI-2). A current that evoked a phosphene that the subject perceived in the whole visual area was delivered continuously for 30 min. Humphrey visual field testing was performed after every third transcorneal electrical stimulation treatment. Changes in mean deviation (MD) values were evaluated with a linear regression model. Transcorneal electrical stimulation was performed 18.2 ± 9.4 times over a period of 49.8 ± 23.0 months. The average pretranscorneal electrical stimulation intraocular pressure, best corrected visual acuity, and MD values were 11.8 ± 1.79 mmHg, 0.14 ± 0.19 (logMAR) and −17.28 ± 6.24 dB, respectively. No significant differences were observed in intraocular pressure before and after transcorneal electrical stimulation. However, there was a significant positive linear relationship between changes in MD values and the number of transcorneal electrical stimulation treatments (R2 = 0.176, P = 0.005, Spearman correlation R = 0.294, P = 0.008). Transcorneal electrical stimulation treatment may improve glaucomatous visual field defects in subjects with primary open-angle glaucoma. Large-scale studies are necessary to confirm these preliminary findings.

KW - Neuroprotection

KW - Primary open-angle glaucoma

KW - Transcorneal electrical stimulation

KW - Visual field

UR - http://www.scopus.com/inward/record.url?scp=85050282367&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85050282367&partnerID=8YFLogxK

U2 - 10.2302/kjm.2017-0015-OA

DO - 10.2302/kjm.2017-0015-OA

M3 - Article

VL - 67

SP - 45

EP - 53

JO - Keio Journal of Medicine

JF - Keio Journal of Medicine

SN - 0022-9717

IS - 3

ER -