Abstract
Pulsed brachytherapy is starting to be used for patients with various kinds of carcinoma, in the expectation of fair treatment results without increasing the late radiation-induced damage. We calculated the early and late biologically effective dose (BED) of this modality to predict early and late radiation damage based on the linear-quadratic model (L-Q model). The way to set the values of α/β and μ (factor of repair) in the L-Q model remains controversial. The value of α/β has been fixed at 3Gy for the late effect and 10Gy for the early effect in recent studies. In this study, we applied these α/β values to calculate the BED, however, the effects of its alteration ranged from 0.5Gy through 15Gy on BED were also analysed. We assumed μ = 0.5 (T1/2 = 1-2hours) in this study, but we also tried to examine the effects of its variation. Our results indicate that pulsed brachytherapy is a safe treatment procedure even if the dose-rate ranges from 1Gy/hr through 100Gy/hr, but the fractionation number should be increased when using a very high dose rate. Pulsed brachytherapy should be applied cautiously for tissues with a small μ value, such as the spinal cord, because an extremely high late BED would be expected in such cases.
Original language | English |
---|---|
Pages (from-to) | 595-598 |
Number of pages | 4 |
Journal | Nippon Acta Radiologica |
Volume | 56 |
Issue number | 8 |
Publication status | Published - 1996 Jul |
Keywords
- Dose-rate
- Linear-quadratic model
- Pulsed brachytherapy
- Radiotheraphy
ASJC Scopus subject areas
- Radiology Nuclear Medicine and imaging
- Oncology