Thinning pipe wall evaluation by using electric potential difference method

Satoshi Honda

Research output: Chapter in Book/Report/Conference proceedingConference contribution

5 Citations (Scopus)

Abstract

Electric potential difference method is widely used for diagnosing and monitoring flow conduits. We study the prospect of the method to evaluate pipe wall thinning. Based on our previous work on non-intrusive resistance thermometer for fast breeder reactor, this paper describes theoretical analysis and the 3-D exact solution of the electrical potential field in pipe wall. Complex potentials are applied for 2-D approximation of the potential on the wall surface to evaluate the pipe wall thinning.

Original languageEnglish
Title of host publicationProceedings of the SICE Annual Conference
Pages520-523
Number of pages4
DOIs
Publication statusPublished - 2008
EventSICE Annual Conference 2008 - International Conference on Instrumentation, Control and Information Technology - Tokyo, Japan
Duration: 2008 Aug 202008 Aug 22

Other

OtherSICE Annual Conference 2008 - International Conference on Instrumentation, Control and Information Technology
CountryJapan
CityTokyo
Period08/8/2008/8/22

Fingerprint

Pipe
Electric potential
Confined flow
Breeder reactors
Thermometers
Monitoring

Keywords

  • Electric potential
  • Forward problem
  • Pipe line diagnosis
  • Potential analysis

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Control and Systems Engineering
  • Computer Science Applications

Cite this

Honda, S. (2008). Thinning pipe wall evaluation by using electric potential difference method. In Proceedings of the SICE Annual Conference (pp. 520-523). [4654710] https://doi.org/10.1109/SICE.2008.4654710

Thinning pipe wall evaluation by using electric potential difference method. / Honda, Satoshi.

Proceedings of the SICE Annual Conference. 2008. p. 520-523 4654710.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Honda, S 2008, Thinning pipe wall evaluation by using electric potential difference method. in Proceedings of the SICE Annual Conference., 4654710, pp. 520-523, SICE Annual Conference 2008 - International Conference on Instrumentation, Control and Information Technology, Tokyo, Japan, 08/8/20. https://doi.org/10.1109/SICE.2008.4654710
Honda S. Thinning pipe wall evaluation by using electric potential difference method. In Proceedings of the SICE Annual Conference. 2008. p. 520-523. 4654710 https://doi.org/10.1109/SICE.2008.4654710
Honda, Satoshi. / Thinning pipe wall evaluation by using electric potential difference method. Proceedings of the SICE Annual Conference. 2008. pp. 520-523
@inproceedings{577188c233a743f688d02d2c44de4502,
title = "Thinning pipe wall evaluation by using electric potential difference method",
abstract = "Electric potential difference method is widely used for diagnosing and monitoring flow conduits. We study the prospect of the method to evaluate pipe wall thinning. Based on our previous work on non-intrusive resistance thermometer for fast breeder reactor, this paper describes theoretical analysis and the 3-D exact solution of the electrical potential field in pipe wall. Complex potentials are applied for 2-D approximation of the potential on the wall surface to evaluate the pipe wall thinning.",
keywords = "Electric potential, Forward problem, Pipe line diagnosis, Potential analysis",
author = "Satoshi Honda",
year = "2008",
doi = "10.1109/SICE.2008.4654710",
language = "English",
isbn = "9784907764296",
pages = "520--523",
booktitle = "Proceedings of the SICE Annual Conference",

}

TY - GEN

T1 - Thinning pipe wall evaluation by using electric potential difference method

AU - Honda, Satoshi

PY - 2008

Y1 - 2008

N2 - Electric potential difference method is widely used for diagnosing and monitoring flow conduits. We study the prospect of the method to evaluate pipe wall thinning. Based on our previous work on non-intrusive resistance thermometer for fast breeder reactor, this paper describes theoretical analysis and the 3-D exact solution of the electrical potential field in pipe wall. Complex potentials are applied for 2-D approximation of the potential on the wall surface to evaluate the pipe wall thinning.

AB - Electric potential difference method is widely used for diagnosing and monitoring flow conduits. We study the prospect of the method to evaluate pipe wall thinning. Based on our previous work on non-intrusive resistance thermometer for fast breeder reactor, this paper describes theoretical analysis and the 3-D exact solution of the electrical potential field in pipe wall. Complex potentials are applied for 2-D approximation of the potential on the wall surface to evaluate the pipe wall thinning.

KW - Electric potential

KW - Forward problem

KW - Pipe line diagnosis

KW - Potential analysis

UR - http://www.scopus.com/inward/record.url?scp=56749177836&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=56749177836&partnerID=8YFLogxK

U2 - 10.1109/SICE.2008.4654710

DO - 10.1109/SICE.2008.4654710

M3 - Conference contribution

SN - 9784907764296

SP - 520

EP - 523

BT - Proceedings of the SICE Annual Conference

ER -