Use of a titanium mesh cage for posterior atlantoaxial arthrodesis. Technical note

Morio Matsumoto, Kazuhiro Chiba, Takashi Tsuji, Hirofumi Maruiwa, Yoshiaki Toyama, Jun Ogawa

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

The authors placed titanium mesh cages to achieve posterior atlantoaxial fixation in five patients with atlantoaxial instability caused by rheumatoid arthritis or os odontoideum. A mesh cage packed with autologous cancellous bone was placed between the C-1 posterior arch and the C-2 lamina and was tightly connected with titanium wires. Combined with the use of transarticular screws, this procedure provided very rigid fixation. Solid fusion was achieved in all patients without major complications. The advantages of this method include more stable fixation, better control of the atlantoaxial fixation angle, and reduced donor-site morbidity compared with a conventional atlantoaxial arthrodesis in which an autologous iliac crest graft is used.

Original languageEnglish
Pages (from-to)127-130
Number of pages4
JournalJournal of Neurosurgery
Volume96
Issue number1 SUPPL.
Publication statusPublished - 2002

Fingerprint

Arthrodesis
Titanium
Rheumatoid Arthritis
Tissue Donors
Morbidity
Transplants
Cancellous Bone

Keywords

  • Atlantoaxial fusion
  • Atlantoaxial stabilization
  • Titanium mesh cage

ASJC Scopus subject areas

  • Clinical Neurology
  • Neuroscience(all)

Cite this

Matsumoto, M., Chiba, K., Tsuji, T., Maruiwa, H., Toyama, Y., & Ogawa, J. (2002). Use of a titanium mesh cage for posterior atlantoaxial arthrodesis. Technical note. Journal of Neurosurgery, 96(1 SUPPL.), 127-130.

Use of a titanium mesh cage for posterior atlantoaxial arthrodesis. Technical note. / Matsumoto, Morio; Chiba, Kazuhiro; Tsuji, Takashi; Maruiwa, Hirofumi; Toyama, Yoshiaki; Ogawa, Jun.

In: Journal of Neurosurgery, Vol. 96, No. 1 SUPPL., 2002, p. 127-130.

Research output: Contribution to journalArticle

Matsumoto, M, Chiba, K, Tsuji, T, Maruiwa, H, Toyama, Y & Ogawa, J 2002, 'Use of a titanium mesh cage for posterior atlantoaxial arthrodesis. Technical note', Journal of Neurosurgery, vol. 96, no. 1 SUPPL., pp. 127-130.
Matsumoto M, Chiba K, Tsuji T, Maruiwa H, Toyama Y, Ogawa J. Use of a titanium mesh cage for posterior atlantoaxial arthrodesis. Technical note. Journal of Neurosurgery. 2002;96(1 SUPPL.):127-130.
Matsumoto, Morio ; Chiba, Kazuhiro ; Tsuji, Takashi ; Maruiwa, Hirofumi ; Toyama, Yoshiaki ; Ogawa, Jun. / Use of a titanium mesh cage for posterior atlantoaxial arthrodesis. Technical note. In: Journal of Neurosurgery. 2002 ; Vol. 96, No. 1 SUPPL. pp. 127-130.
@article{edab6578f519407d9b8fb9dbc8682bde,
title = "Use of a titanium mesh cage for posterior atlantoaxial arthrodesis. Technical note",
abstract = "The authors placed titanium mesh cages to achieve posterior atlantoaxial fixation in five patients with atlantoaxial instability caused by rheumatoid arthritis or os odontoideum. A mesh cage packed with autologous cancellous bone was placed between the C-1 posterior arch and the C-2 lamina and was tightly connected with titanium wires. Combined with the use of transarticular screws, this procedure provided very rigid fixation. Solid fusion was achieved in all patients without major complications. The advantages of this method include more stable fixation, better control of the atlantoaxial fixation angle, and reduced donor-site morbidity compared with a conventional atlantoaxial arthrodesis in which an autologous iliac crest graft is used.",
keywords = "Atlantoaxial fusion, Atlantoaxial stabilization, Titanium mesh cage",
author = "Morio Matsumoto and Kazuhiro Chiba and Takashi Tsuji and Hirofumi Maruiwa and Yoshiaki Toyama and Jun Ogawa",
year = "2002",
language = "English",
volume = "96",
pages = "127--130",
journal = "Journal of Neurosurgery",
issn = "0022-3085",
publisher = "American Association of Neurological Surgeons",
number = "1 SUPPL.",

}

TY - JOUR

T1 - Use of a titanium mesh cage for posterior atlantoaxial arthrodesis. Technical note

AU - Matsumoto, Morio

AU - Chiba, Kazuhiro

AU - Tsuji, Takashi

AU - Maruiwa, Hirofumi

AU - Toyama, Yoshiaki

AU - Ogawa, Jun

PY - 2002

Y1 - 2002

N2 - The authors placed titanium mesh cages to achieve posterior atlantoaxial fixation in five patients with atlantoaxial instability caused by rheumatoid arthritis or os odontoideum. A mesh cage packed with autologous cancellous bone was placed between the C-1 posterior arch and the C-2 lamina and was tightly connected with titanium wires. Combined with the use of transarticular screws, this procedure provided very rigid fixation. Solid fusion was achieved in all patients without major complications. The advantages of this method include more stable fixation, better control of the atlantoaxial fixation angle, and reduced donor-site morbidity compared with a conventional atlantoaxial arthrodesis in which an autologous iliac crest graft is used.

AB - The authors placed titanium mesh cages to achieve posterior atlantoaxial fixation in five patients with atlantoaxial instability caused by rheumatoid arthritis or os odontoideum. A mesh cage packed with autologous cancellous bone was placed between the C-1 posterior arch and the C-2 lamina and was tightly connected with titanium wires. Combined with the use of transarticular screws, this procedure provided very rigid fixation. Solid fusion was achieved in all patients without major complications. The advantages of this method include more stable fixation, better control of the atlantoaxial fixation angle, and reduced donor-site morbidity compared with a conventional atlantoaxial arthrodesis in which an autologous iliac crest graft is used.

KW - Atlantoaxial fusion

KW - Atlantoaxial stabilization

KW - Titanium mesh cage

UR - http://www.scopus.com/inward/record.url?scp=0036122471&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036122471&partnerID=8YFLogxK

M3 - Article

VL - 96

SP - 127

EP - 130

JO - Journal of Neurosurgery

JF - Journal of Neurosurgery

SN - 0022-3085

IS - 1 SUPPL.

ER -