Utility of Intraductal Ultrasonography as a Diagnostic Tool in Patients with Early Distal Cholangiocarcinoma

Yasuhiro Ito, Shintaro Shibutani, Tomohisa Egawa, Shinobu Hayashi, Atsushi Nagashima, Yuko Kitagawa

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

BACKGROUND/AIMS: It is difficult to diagnose cholangiocarcinoma in the early stages because most patients present with jaundice, which is generally thought to be the most important symptom at diagnosis. Despite improvements to surgical instruments and techniques, these rates are not quite satisfactory. Intraductal ultrasound (IDUS) is easy to handle due to the wire-guided, thin-caliber, and high-frequency probe. The purpose of the present study was to assess the efficacy of IDUS as a diagnostic tool for patients with early distal cholangiocarcinoma.

METHODOLOGY: We enrolled 23 with early distal cholangiocarcinoma. The cholangiography and IDUS findings were retrospectively analyzed. The morphology of the tumors detected by IDUS was also classified including localized wall thickening, polypoid lesion, and sessile tumor.

RESULTS: The morphologies on IDUS were as follows: five (21.7%) localized wall thickenings, five (21.7%) polypoid lesions, and 13 (56.5%) sessile tumors.

CONCLUSIONS: Since forceps biopsy complemented by IDUS can substantially improve the diagnostic rate, pathological investigations should be performed simultaneously after detection by IDUS. We believe that noninvasive modalities should be followed by IDUS and used as a decisive approach to distinguish between benign and malignant status.

Original languageEnglish
Pages (from-to)782-786
Number of pages5
JournalHepato-Gastroenterology
Volume62
Issue number140
Publication statusPublished - 2015 Jun 1

Fingerprint

Cholangiocarcinoma
Ultrasonography
Surgical Instruments
Neoplasms
Cholangiography
Jaundice
Biopsy

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Utility of Intraductal Ultrasonography as a Diagnostic Tool in Patients with Early Distal Cholangiocarcinoma. / Ito, Yasuhiro; Shibutani, Shintaro; Egawa, Tomohisa; Hayashi, Shinobu; Nagashima, Atsushi; Kitagawa, Yuko.

In: Hepato-Gastroenterology, Vol. 62, No. 140, 01.06.2015, p. 782-786.

Research output: Contribution to journalArticle

Ito, Y, Shibutani, S, Egawa, T, Hayashi, S, Nagashima, A & Kitagawa, Y 2015, 'Utility of Intraductal Ultrasonography as a Diagnostic Tool in Patients with Early Distal Cholangiocarcinoma', Hepato-Gastroenterology, vol. 62, no. 140, pp. 782-786.
Ito, Yasuhiro ; Shibutani, Shintaro ; Egawa, Tomohisa ; Hayashi, Shinobu ; Nagashima, Atsushi ; Kitagawa, Yuko. / Utility of Intraductal Ultrasonography as a Diagnostic Tool in Patients with Early Distal Cholangiocarcinoma. In: Hepato-Gastroenterology. 2015 ; Vol. 62, No. 140. pp. 782-786.
@article{2c550fc78b7f4d81903287dcd6059bc1,
title = "Utility of Intraductal Ultrasonography as a Diagnostic Tool in Patients with Early Distal Cholangiocarcinoma",
abstract = "BACKGROUND/AIMS: It is difficult to diagnose cholangiocarcinoma in the early stages because most patients present with jaundice, which is generally thought to be the most important symptom at diagnosis. Despite improvements to surgical instruments and techniques, these rates are not quite satisfactory. Intraductal ultrasound (IDUS) is easy to handle due to the wire-guided, thin-caliber, and high-frequency probe. The purpose of the present study was to assess the efficacy of IDUS as a diagnostic tool for patients with early distal cholangiocarcinoma.METHODOLOGY: We enrolled 23 with early distal cholangiocarcinoma. The cholangiography and IDUS findings were retrospectively analyzed. The morphology of the tumors detected by IDUS was also classified including localized wall thickening, polypoid lesion, and sessile tumor.RESULTS: The morphologies on IDUS were as follows: five (21.7{\%}) localized wall thickenings, five (21.7{\%}) polypoid lesions, and 13 (56.5{\%}) sessile tumors.CONCLUSIONS: Since forceps biopsy complemented by IDUS can substantially improve the diagnostic rate, pathological investigations should be performed simultaneously after detection by IDUS. We believe that noninvasive modalities should be followed by IDUS and used as a decisive approach to distinguish between benign and malignant status.",
author = "Yasuhiro Ito and Shintaro Shibutani and Tomohisa Egawa and Shinobu Hayashi and Atsushi Nagashima and Yuko Kitagawa",
year = "2015",
month = "6",
day = "1",
language = "English",
volume = "62",
pages = "782--786",
journal = "Acta hepato-splenologica",
issn = "0172-6390",
publisher = "H.G.E. Update Medical Publishing Ltd.",
number = "140",

}

TY - JOUR

T1 - Utility of Intraductal Ultrasonography as a Diagnostic Tool in Patients with Early Distal Cholangiocarcinoma

AU - Ito, Yasuhiro

AU - Shibutani, Shintaro

AU - Egawa, Tomohisa

AU - Hayashi, Shinobu

AU - Nagashima, Atsushi

AU - Kitagawa, Yuko

PY - 2015/6/1

Y1 - 2015/6/1

N2 - BACKGROUND/AIMS: It is difficult to diagnose cholangiocarcinoma in the early stages because most patients present with jaundice, which is generally thought to be the most important symptom at diagnosis. Despite improvements to surgical instruments and techniques, these rates are not quite satisfactory. Intraductal ultrasound (IDUS) is easy to handle due to the wire-guided, thin-caliber, and high-frequency probe. The purpose of the present study was to assess the efficacy of IDUS as a diagnostic tool for patients with early distal cholangiocarcinoma.METHODOLOGY: We enrolled 23 with early distal cholangiocarcinoma. The cholangiography and IDUS findings were retrospectively analyzed. The morphology of the tumors detected by IDUS was also classified including localized wall thickening, polypoid lesion, and sessile tumor.RESULTS: The morphologies on IDUS were as follows: five (21.7%) localized wall thickenings, five (21.7%) polypoid lesions, and 13 (56.5%) sessile tumors.CONCLUSIONS: Since forceps biopsy complemented by IDUS can substantially improve the diagnostic rate, pathological investigations should be performed simultaneously after detection by IDUS. We believe that noninvasive modalities should be followed by IDUS and used as a decisive approach to distinguish between benign and malignant status.

AB - BACKGROUND/AIMS: It is difficult to diagnose cholangiocarcinoma in the early stages because most patients present with jaundice, which is generally thought to be the most important symptom at diagnosis. Despite improvements to surgical instruments and techniques, these rates are not quite satisfactory. Intraductal ultrasound (IDUS) is easy to handle due to the wire-guided, thin-caliber, and high-frequency probe. The purpose of the present study was to assess the efficacy of IDUS as a diagnostic tool for patients with early distal cholangiocarcinoma.METHODOLOGY: We enrolled 23 with early distal cholangiocarcinoma. The cholangiography and IDUS findings were retrospectively analyzed. The morphology of the tumors detected by IDUS was also classified including localized wall thickening, polypoid lesion, and sessile tumor.RESULTS: The morphologies on IDUS were as follows: five (21.7%) localized wall thickenings, five (21.7%) polypoid lesions, and 13 (56.5%) sessile tumors.CONCLUSIONS: Since forceps biopsy complemented by IDUS can substantially improve the diagnostic rate, pathological investigations should be performed simultaneously after detection by IDUS. We believe that noninvasive modalities should be followed by IDUS and used as a decisive approach to distinguish between benign and malignant status.

UR - http://www.scopus.com/inward/record.url?scp=84979854898&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84979854898&partnerID=8YFLogxK

M3 - Article

C2 - 26902000

AN - SCOPUS:84979854898

VL - 62

SP - 782

EP - 786

JO - Acta hepato-splenologica

JF - Acta hepato-splenologica

SN - 0172-6390

IS - 140

ER -