X ray CT inspection algorithm to correct missing data

Toshiyuki Kaneko, Toshiyuki Tanaka, Kazuo Kikuchi

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

X ray CT is for nondestructive inspection in industrial field. In X ray CY inspection, the problem is called "metal artifact" on the reconstructed image is one of the biggest issue. This study aims to reduce metal artifact. Metal artifact is caused primarily by missing projection data from every projection angle. So ,we propose the algorithm for correcting the missing projection data and confirm availability for nondestructive inspection in industrial field.

Original languageEnglish
Title of host publicationICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings
Pages3405-3408
Number of pages4
Publication statusPublished - 2009
EventICROS-SICE International Joint Conference 2009, ICCAS-SICE 2009 - Fukuoka, Japan
Duration: 2009 Aug 182009 Aug 21

Other

OtherICROS-SICE International Joint Conference 2009, ICCAS-SICE 2009
CountryJapan
CityFukuoka
Period09/8/1809/8/21

Fingerprint

Inspection
X rays
Metals
Availability

Keywords

  • 3D reconstruction
  • Feldkamp algorithm
  • X ray computed tomography

ASJC Scopus subject areas

  • Information Systems
  • Control and Systems Engineering
  • Industrial and Manufacturing Engineering

Cite this

Kaneko, T., Tanaka, T., & Kikuchi, K. (2009). X ray CT inspection algorithm to correct missing data. In ICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings (pp. 3405-3408). [5335236]

X ray CT inspection algorithm to correct missing data. / Kaneko, Toshiyuki; Tanaka, Toshiyuki; Kikuchi, Kazuo.

ICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings. 2009. p. 3405-3408 5335236.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Kaneko, T, Tanaka, T & Kikuchi, K 2009, X ray CT inspection algorithm to correct missing data. in ICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings., 5335236, pp. 3405-3408, ICROS-SICE International Joint Conference 2009, ICCAS-SICE 2009, Fukuoka, Japan, 09/8/18.
Kaneko T, Tanaka T, Kikuchi K. X ray CT inspection algorithm to correct missing data. In ICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings. 2009. p. 3405-3408. 5335236
Kaneko, Toshiyuki ; Tanaka, Toshiyuki ; Kikuchi, Kazuo. / X ray CT inspection algorithm to correct missing data. ICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings. 2009. pp. 3405-3408
@inproceedings{f28a2c2fcf3947e28e9f537a1b9de08f,
title = "X ray CT inspection algorithm to correct missing data",
abstract = "X ray CT is for nondestructive inspection in industrial field. In X ray CY inspection, the problem is called {"}metal artifact{"} on the reconstructed image is one of the biggest issue. This study aims to reduce metal artifact. Metal artifact is caused primarily by missing projection data from every projection angle. So ,we propose the algorithm for correcting the missing projection data and confirm availability for nondestructive inspection in industrial field.",
keywords = "3D reconstruction, Feldkamp algorithm, X ray computed tomography",
author = "Toshiyuki Kaneko and Toshiyuki Tanaka and Kazuo Kikuchi",
year = "2009",
language = "English",
isbn = "9784907764333",
pages = "3405--3408",
booktitle = "ICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings",

}

TY - GEN

T1 - X ray CT inspection algorithm to correct missing data

AU - Kaneko, Toshiyuki

AU - Tanaka, Toshiyuki

AU - Kikuchi, Kazuo

PY - 2009

Y1 - 2009

N2 - X ray CT is for nondestructive inspection in industrial field. In X ray CY inspection, the problem is called "metal artifact" on the reconstructed image is one of the biggest issue. This study aims to reduce metal artifact. Metal artifact is caused primarily by missing projection data from every projection angle. So ,we propose the algorithm for correcting the missing projection data and confirm availability for nondestructive inspection in industrial field.

AB - X ray CT is for nondestructive inspection in industrial field. In X ray CY inspection, the problem is called "metal artifact" on the reconstructed image is one of the biggest issue. This study aims to reduce metal artifact. Metal artifact is caused primarily by missing projection data from every projection angle. So ,we propose the algorithm for correcting the missing projection data and confirm availability for nondestructive inspection in industrial field.

KW - 3D reconstruction

KW - Feldkamp algorithm

KW - X ray computed tomography

UR - http://www.scopus.com/inward/record.url?scp=77951113074&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77951113074&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:77951113074

SN - 9784907764333

SP - 3405

EP - 3408

BT - ICCAS-SICE 2009 - ICROS-SICE International Joint Conference 2009, Proceedings

ER -