A gold nanoparticle modified boron-doped diamond electrode was developed as a transducer for biochemical oxygen demand (BOD) measurements. Rhodotorula mucilaginosa UICC Y-181 was immobilized in a sodium alginate matrix, and used as a biosensing agent. Cyclic voltammetry was applied to study the oxygen reduction reaction at the electrode, while amperometry was employed to detect oxygen, which was not consumed by the microorganisms. The optimum waiting time of 25 min was observed using 1-mm thickness of yeast film. A comparison against the system with free yeast cells shows less sensitivity of the current responses with a linear dynamic range (R<sup>2</sup> = 0.99) of from 0.10 mM to 0.90 mM glucose (equivalent to 10 - 90 mg/L BOD) with an estimated limit of detection of 1.90 mg/L BOD. However, a better stability of the current responses could be achieved with an RSD of 3.35%. Moreover, less influence from the presence of copper ions was observed. The results indicate that the yeast-immobilized BOD sensors is more suitable to be applied in a real condition.

Original languageEnglish
Pages (from-to)643-649
Number of pages7
JournalAnalytical Sciences
Volume31
Issue number7
Publication statusPublished - 2015

Fingerprint

Diamond
Boron
Biochemical oxygen demand
Yeast
Electrodes
Sensors
Oxygen
Gold
Microorganisms
Cyclic voltammetry
Copper
Transducers
Cells
Ions
Nanoparticles
Glucose

Keywords

  • Alginate matrix
  • BOD sensors
  • Gold-modified diamond
  • Oxygen
  • Rhodotorula mucilaginosa UICC Y-181

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Yeast-based biochemical oxygen demand sensors using goldmodified boron-doped diamond electrodes. / Ivandini, Tribidasari A.; Harmesa; Saepudin, Endang; Einaga, Yasuaki.

In: Analytical Sciences, Vol. 31, No. 7, 2015, p. 643-649.

Research output: Contribution to journalArticle

Ivandini, Tribidasari A. ; Harmesa ; Saepudin, Endang ; Einaga, Yasuaki. / Yeast-based biochemical oxygen demand sensors using goldmodified boron-doped diamond electrodes. In: Analytical Sciences. 2015 ; Vol. 31, No. 7. pp. 643-649.
@article{0b75a5b6b3624b3582cadb1ff9fa56e2,
title = "Yeast-based biochemical oxygen demand sensors using goldmodified boron-doped diamond electrodes",
abstract = "A gold nanoparticle modified boron-doped diamond electrode was developed as a transducer for biochemical oxygen demand (BOD) measurements. Rhodotorula mucilaginosa UICC Y-181 was immobilized in a sodium alginate matrix, and used as a biosensing agent. Cyclic voltammetry was applied to study the oxygen reduction reaction at the electrode, while amperometry was employed to detect oxygen, which was not consumed by the microorganisms. The optimum waiting time of 25 min was observed using 1-mm thickness of yeast film. A comparison against the system with free yeast cells shows less sensitivity of the current responses with a linear dynamic range (R2 = 0.99) of from 0.10 mM to 0.90 mM glucose (equivalent to 10 - 90 mg/L BOD) with an estimated limit of detection of 1.90 mg/L BOD. However, a better stability of the current responses could be achieved with an RSD of 3.35{\%}. Moreover, less influence from the presence of copper ions was observed. The results indicate that the yeast-immobilized BOD sensors is more suitable to be applied in a real condition.",
keywords = "Alginate matrix, BOD sensors, Gold-modified diamond, Oxygen, Rhodotorula mucilaginosa UICC Y-181",
author = "Ivandini, {Tribidasari A.} and Harmesa and Endang Saepudin and Yasuaki Einaga",
year = "2015",
language = "English",
volume = "31",
pages = "643--649",
journal = "Analytical Sciences",
issn = "0910-6340",
publisher = "Japan Society for Analytical Chemistry",
number = "7",

}

TY - JOUR

T1 - Yeast-based biochemical oxygen demand sensors using goldmodified boron-doped diamond electrodes

AU - Ivandini, Tribidasari A.

AU - Harmesa,

AU - Saepudin, Endang

AU - Einaga, Yasuaki

PY - 2015

Y1 - 2015

N2 - A gold nanoparticle modified boron-doped diamond electrode was developed as a transducer for biochemical oxygen demand (BOD) measurements. Rhodotorula mucilaginosa UICC Y-181 was immobilized in a sodium alginate matrix, and used as a biosensing agent. Cyclic voltammetry was applied to study the oxygen reduction reaction at the electrode, while amperometry was employed to detect oxygen, which was not consumed by the microorganisms. The optimum waiting time of 25 min was observed using 1-mm thickness of yeast film. A comparison against the system with free yeast cells shows less sensitivity of the current responses with a linear dynamic range (R2 = 0.99) of from 0.10 mM to 0.90 mM glucose (equivalent to 10 - 90 mg/L BOD) with an estimated limit of detection of 1.90 mg/L BOD. However, a better stability of the current responses could be achieved with an RSD of 3.35%. Moreover, less influence from the presence of copper ions was observed. The results indicate that the yeast-immobilized BOD sensors is more suitable to be applied in a real condition.

AB - A gold nanoparticle modified boron-doped diamond electrode was developed as a transducer for biochemical oxygen demand (BOD) measurements. Rhodotorula mucilaginosa UICC Y-181 was immobilized in a sodium alginate matrix, and used as a biosensing agent. Cyclic voltammetry was applied to study the oxygen reduction reaction at the electrode, while amperometry was employed to detect oxygen, which was not consumed by the microorganisms. The optimum waiting time of 25 min was observed using 1-mm thickness of yeast film. A comparison against the system with free yeast cells shows less sensitivity of the current responses with a linear dynamic range (R2 = 0.99) of from 0.10 mM to 0.90 mM glucose (equivalent to 10 - 90 mg/L BOD) with an estimated limit of detection of 1.90 mg/L BOD. However, a better stability of the current responses could be achieved with an RSD of 3.35%. Moreover, less influence from the presence of copper ions was observed. The results indicate that the yeast-immobilized BOD sensors is more suitable to be applied in a real condition.

KW - Alginate matrix

KW - BOD sensors

KW - Gold-modified diamond

KW - Oxygen

KW - Rhodotorula mucilaginosa UICC Y-181

UR - http://www.scopus.com/inward/record.url?scp=84937038553&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84937038553&partnerID=8YFLogxK

M3 - Article

VL - 31

SP - 643

EP - 649

JO - Analytical Sciences

JF - Analytical Sciences

SN - 0910-6340

IS - 7

ER -