A new configuration of electro-magnetic flowmeters with self-calibration theoretical analysis

S. Honda, T. Yamamoto

研究成果: Paper査読

4 被引用数 (Scopus)

抄録

Electro-magnetic flowmeters have been one of the standard flowmeters to measure liquid flowrate in industry. This study proposes a new configuration consisting of two pairs of exciting magnetic coils and a pair of signal pickup electrodes with the higher driving frequencies than those of conventional electro-magnetic flowmeters. This rather complex configuration brings the meters a function of self-calibration and lowers the condition of the fluid conductivity for the measurement to such as pure distilled water. The theoretical analysis agrees well with experimental results and it clarifies the feasibility of the proposed configuration.

本文言語English
ページ441-445
ページ数5
出版ステータスPublished - 2004 12月 1
イベントSICE Annual Conference 2004 - Sapporo, Japan
継続期間: 2004 8月 42004 8月 6

Other

OtherSICE Annual Conference 2004
国/地域Japan
CitySapporo
Period04/8/404/8/6

ASJC Scopus subject areas

  • 制御およびシステム工学
  • コンピュータ サイエンスの応用
  • 電子工学および電気工学

フィンガープリント

「A new configuration of electro-magnetic flowmeters with self-calibration theoretical analysis」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。