Analysis of plasma distribution near the extraction region in surface produced negative ion sources

A. Fukano, Akiyoshi Hatayama

研究成果: Article

2 引用 (Scopus)

抄録

In study of a negative ion source, it is important to understand the plasma characteristics near the extraction region. A recent experiment in the NIFS-R&D ion source has suggested that a "double ion plasma layer" which is a region consisting of hydrogen positive and negative ions exists near the plasma grid (PG). Density distribution of plasma near the extraction region is studied analytically. It is shown that the density distribution depends on an amount of the surface produced negative ions and the double ion plasma layer is formed near the PG surface for the case of strong surface production.

元の言語English
記事番号4850696
ジャーナルReview of Scientific Instruments
85
発行部数2
DOI
出版物ステータスPublished - 2014 2

Fingerprint

Ion sources
negative ions
ion sources
Negative ions
Plasmas
plasma layers
density distribution
grids
hydrogen ions
positive ions
ions
Ions
Positive ions
Hydrogen
Experiments

ASJC Scopus subject areas

  • Instrumentation

これを引用

Analysis of plasma distribution near the extraction region in surface produced negative ion sources. / Fukano, A.; Hatayama, Akiyoshi.

:: Review of Scientific Instruments, 巻 85, 番号 2, 4850696, 02.2014.

研究成果: Article

@article{6cf5edd3fce3420ba8d5d76128daac4f,
title = "Analysis of plasma distribution near the extraction region in surface produced negative ion sources",
abstract = "In study of a negative ion source, it is important to understand the plasma characteristics near the extraction region. A recent experiment in the NIFS-R&D ion source has suggested that a {"}double ion plasma layer{"} which is a region consisting of hydrogen positive and negative ions exists near the plasma grid (PG). Density distribution of plasma near the extraction region is studied analytically. It is shown that the density distribution depends on an amount of the surface produced negative ions and the double ion plasma layer is formed near the PG surface for the case of strong surface production.",
author = "A. Fukano and Akiyoshi Hatayama",
year = "2014",
month = "2",
doi = "10.1063/1.4850696",
language = "English",
volume = "85",
journal = "Review of Scientific Instruments",
issn = "0034-6748",
publisher = "American Institute of Physics Publising LLC",
number = "2",

}

TY - JOUR

T1 - Analysis of plasma distribution near the extraction region in surface produced negative ion sources

AU - Fukano, A.

AU - Hatayama, Akiyoshi

PY - 2014/2

Y1 - 2014/2

N2 - In study of a negative ion source, it is important to understand the plasma characteristics near the extraction region. A recent experiment in the NIFS-R&D ion source has suggested that a "double ion plasma layer" which is a region consisting of hydrogen positive and negative ions exists near the plasma grid (PG). Density distribution of plasma near the extraction region is studied analytically. It is shown that the density distribution depends on an amount of the surface produced negative ions and the double ion plasma layer is formed near the PG surface for the case of strong surface production.

AB - In study of a negative ion source, it is important to understand the plasma characteristics near the extraction region. A recent experiment in the NIFS-R&D ion source has suggested that a "double ion plasma layer" which is a region consisting of hydrogen positive and negative ions exists near the plasma grid (PG). Density distribution of plasma near the extraction region is studied analytically. It is shown that the density distribution depends on an amount of the surface produced negative ions and the double ion plasma layer is formed near the PG surface for the case of strong surface production.

UR - http://www.scopus.com/inward/record.url?scp=84893128537&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84893128537&partnerID=8YFLogxK

U2 - 10.1063/1.4850696

DO - 10.1063/1.4850696

M3 - Article

AN - SCOPUS:84893128537

VL - 85

JO - Review of Scientific Instruments

JF - Review of Scientific Instruments

SN - 0034-6748

IS - 2

M1 - 4850696

ER -