TY - JOUR
T1 - Appropriateness of Transcatheter Aortic Valve Replacement
T2 - Insight From the OCEAN-TAVI Registry
AU - Inohara, Taku
AU - Vemulapalli, Sreekanth
AU - Kohsaka, Shun
AU - Yashima, Fumiaki
AU - Watanabe, Yusuke
AU - Shirai, Shinichi
AU - Tada, Norio
AU - Araki, Motoharu
AU - Naganuma, Toru
AU - Yamanaka, Futoshi
AU - Ueno, Hiroshi
AU - Tabata, Minoru
AU - Mizutani, Kazuki
AU - Higashimori, Akihiro
AU - Takagi, Kensuke
AU - Yamamoto, Masanori
AU - Shimizu, Hideyuki
AU - Fukuda, Keiichi
AU - Hayashida, Kentaro
N1 - Publisher Copyright:
© 2020 American Heart Association, Inc.
PY - 2020/4/1
Y1 - 2020/4/1
N2 - Background: Transcatheter aortic valve replacement (TAVR) is widely used; however, its appropriateness is unknown. We sought to investigate the appropriateness of TAVR. Methods and Results: We assigned appropriateness ratings to patients undergoing TAVR for severe aortic stenosis between October 2013 and May 2017 at 14 Japanese hospitals participating in the optimized transcatheter valvular intervention-transcatheter aortic valve implantation registry according to the US appropriate use criteria for treating severe aortic stenosis. To account for the influence of uncaptured variables on appropriate use criteria ratings, we initially assigned them to a best-case scenario where they were assumed to classify a case to the most appropriate clinical scenario and then to a worst-case scenario where assumed least appropriate. Overall proportion of TAVRs classified as appropriate, maybe appropriate, or rarely appropriate was assessed. In addition, extent of hospital-level variation in rarely appropriate procedures was evaluated. Of 2036 TAVRs (median age [25th, 75th]: 85.0 years [81.0-88.0]; 70.5% female the Society of Thoracic Surgeons Predicted Risk of Mortality score: 6.2% [4.4-8.9]), in the best-case scenario, 177 (8.7%) were not successfully mapped, and 1580 (77.6%) were classified as appropriate, 180 (8.8%) as maybe appropriate, 99 (4.9%) as rarely appropriate, respectively. In the worst-case scenario, the rate of rarely appropriate increased to 6.8%. The majority of rarely appropriate TAVRs was performed in patients with moderate to severe dementia (defined as mini-mental status examination of ≤17), bicuspid aortic valve, or anticipated life expectancy <1 year. There was substantial variation in the proportion of rarely appropriate TAVR across hospitals (median rate of rarely appropriate: 4.9% [3.8-6.6] in the best-case scenario, P<0.001; 6.5% [5.6-8.6] in the worst-case scenario, P<0.001). Conclusions: In clinical practice, the proportion of rarely appropriate TAVRs ranged from 4.9% to 6.8% with substantial institutional variation. Our study elucidates common clinical scenarios deemed rarely appropriate and clarifies the potential targets of quality improvement.
AB - Background: Transcatheter aortic valve replacement (TAVR) is widely used; however, its appropriateness is unknown. We sought to investigate the appropriateness of TAVR. Methods and Results: We assigned appropriateness ratings to patients undergoing TAVR for severe aortic stenosis between October 2013 and May 2017 at 14 Japanese hospitals participating in the optimized transcatheter valvular intervention-transcatheter aortic valve implantation registry according to the US appropriate use criteria for treating severe aortic stenosis. To account for the influence of uncaptured variables on appropriate use criteria ratings, we initially assigned them to a best-case scenario where they were assumed to classify a case to the most appropriate clinical scenario and then to a worst-case scenario where assumed least appropriate. Overall proportion of TAVRs classified as appropriate, maybe appropriate, or rarely appropriate was assessed. In addition, extent of hospital-level variation in rarely appropriate procedures was evaluated. Of 2036 TAVRs (median age [25th, 75th]: 85.0 years [81.0-88.0]; 70.5% female the Society of Thoracic Surgeons Predicted Risk of Mortality score: 6.2% [4.4-8.9]), in the best-case scenario, 177 (8.7%) were not successfully mapped, and 1580 (77.6%) were classified as appropriate, 180 (8.8%) as maybe appropriate, 99 (4.9%) as rarely appropriate, respectively. In the worst-case scenario, the rate of rarely appropriate increased to 6.8%. The majority of rarely appropriate TAVRs was performed in patients with moderate to severe dementia (defined as mini-mental status examination of ≤17), bicuspid aortic valve, or anticipated life expectancy <1 year. There was substantial variation in the proportion of rarely appropriate TAVR across hospitals (median rate of rarely appropriate: 4.9% [3.8-6.6] in the best-case scenario, P<0.001; 6.5% [5.6-8.6] in the worst-case scenario, P<0.001). Conclusions: In clinical practice, the proportion of rarely appropriate TAVRs ranged from 4.9% to 6.8% with substantial institutional variation. Our study elucidates common clinical scenarios deemed rarely appropriate and clarifies the potential targets of quality improvement.
KW - aortic valve
KW - bicuspid aortic valve
KW - dementia
KW - life expectancy
KW - transcatheter aortic valve replacement
UR - http://www.scopus.com/inward/record.url?scp=85083913696&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85083913696&partnerID=8YFLogxK
U2 - 10.1161/CIRCOUTCOMES.119.006146
DO - 10.1161/CIRCOUTCOMES.119.006146
M3 - Article
C2 - 32212825
AN - SCOPUS:85083913696
SN - 1941-7713
VL - 13
SP - E006146
JO - Circulation: Cardiovascular Quality and Outcomes
JF - Circulation: Cardiovascular Quality and Outcomes
IS - 4
ER -