Biexponential apparent diffusion coefficients in prostate cancer

Hiroshi Shinmoto, Koichi Oshio, Akihiro Tanimoto, Nobuya Higuchi, Shigeo Okuda, Sachio Kuribayashi, Robert V. Mulkern

研究成果: Article

86 引用 (Scopus)

抄録

Purpose: The purpose of this study was to investigate the need for biexponential signal decay modeling for prostate cancer diffusion signal decays with b-factor over an extended b-factor range. Materials and Methods: Ten healthy volunteers and 12 patients with a bulky prostate cancer underwent line scan diffusion-weighted MR imaging in which b-factors from 0 to 3000 s/mm2 in 16 steps were sampled. The acquired signal decay curves were fit with both monoexponential and biexponential signal decay functions and a statistical comparison between the two fits was performed. Results: The biexponential model provided a statistically better fit over the monoexponential model on the peripheral zone (PZ), transitional zone (TZ) and prostate cancer. The fast and slow apparent diffusion coefficients (ADCs) in the PZ, TZ and cancer were 2.9±0.2, 0.7±0.2×10-3 mm2/ms (PZ); 2.9±0.4, 0.7±0.2×10-3 mm2/ms (TZ); and 1.7±0.4, 0.3±0.1×10-3 mm2/ms (cancer), respectively. The apparent fractions of the fast diffusion component in the PZ, TZ and cancer were 70±10%, 60±10% and 50±10%, respectively. The fast and slow ADCs of cancer were significantly lower than those of TZ and PZ, and the apparent fraction of the fast diffusion component was significantly smaller in cancer than in PZ. Conclusions: Biexponential diffusion decay functions are required for prostate cancer diffusion signal decay curves when sampled over an extended b-factor range, providing additional, unique tissue characterization parameters for prostate cancer.

元の言語English
ページ(範囲)355-359
ページ数5
ジャーナルMagnetic Resonance Imaging
27
発行部数3
DOI
出版物ステータスPublished - 2009 4

Fingerprint

Prostatic Neoplasms
Neoplasms
Healthy Volunteers
Tissue
Imaging techniques

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging
  • Biomedical Engineering

これを引用

Biexponential apparent diffusion coefficients in prostate cancer. / Shinmoto, Hiroshi; Oshio, Koichi; Tanimoto, Akihiro; Higuchi, Nobuya; Okuda, Shigeo; Kuribayashi, Sachio; Mulkern, Robert V.

:: Magnetic Resonance Imaging, 巻 27, 番号 3, 04.2009, p. 355-359.

研究成果: Article

Shinmoto, Hiroshi ; Oshio, Koichi ; Tanimoto, Akihiro ; Higuchi, Nobuya ; Okuda, Shigeo ; Kuribayashi, Sachio ; Mulkern, Robert V. / Biexponential apparent diffusion coefficients in prostate cancer. :: Magnetic Resonance Imaging. 2009 ; 巻 27, 番号 3. pp. 355-359.
@article{cd0432eb8d724c858963116c521527c0,
title = "Biexponential apparent diffusion coefficients in prostate cancer",
abstract = "Purpose: The purpose of this study was to investigate the need for biexponential signal decay modeling for prostate cancer diffusion signal decays with b-factor over an extended b-factor range. Materials and Methods: Ten healthy volunteers and 12 patients with a bulky prostate cancer underwent line scan diffusion-weighted MR imaging in which b-factors from 0 to 3000 s/mm2 in 16 steps were sampled. The acquired signal decay curves were fit with both monoexponential and biexponential signal decay functions and a statistical comparison between the two fits was performed. Results: The biexponential model provided a statistically better fit over the monoexponential model on the peripheral zone (PZ), transitional zone (TZ) and prostate cancer. The fast and slow apparent diffusion coefficients (ADCs) in the PZ, TZ and cancer were 2.9±0.2, 0.7±0.2×10-3 mm2/ms (PZ); 2.9±0.4, 0.7±0.2×10-3 mm2/ms (TZ); and 1.7±0.4, 0.3±0.1×10-3 mm2/ms (cancer), respectively. The apparent fractions of the fast diffusion component in the PZ, TZ and cancer were 70±10{\%}, 60±10{\%} and 50±10{\%}, respectively. The fast and slow ADCs of cancer were significantly lower than those of TZ and PZ, and the apparent fraction of the fast diffusion component was significantly smaller in cancer than in PZ. Conclusions: Biexponential diffusion decay functions are required for prostate cancer diffusion signal decay curves when sampled over an extended b-factor range, providing additional, unique tissue characterization parameters for prostate cancer.",
keywords = "Biexponential decay, Diffusion, MRI, Prostate cancer",
author = "Hiroshi Shinmoto and Koichi Oshio and Akihiro Tanimoto and Nobuya Higuchi and Shigeo Okuda and Sachio Kuribayashi and Mulkern, {Robert V.}",
year = "2009",
month = "4",
doi = "10.1016/j.mri.2008.07.008",
language = "English",
volume = "27",
pages = "355--359",
journal = "Magnetic Resonance Imaging",
issn = "0730-725X",
publisher = "Elsevier Inc.",
number = "3",

}

TY - JOUR

T1 - Biexponential apparent diffusion coefficients in prostate cancer

AU - Shinmoto, Hiroshi

AU - Oshio, Koichi

AU - Tanimoto, Akihiro

AU - Higuchi, Nobuya

AU - Okuda, Shigeo

AU - Kuribayashi, Sachio

AU - Mulkern, Robert V.

PY - 2009/4

Y1 - 2009/4

N2 - Purpose: The purpose of this study was to investigate the need for biexponential signal decay modeling for prostate cancer diffusion signal decays with b-factor over an extended b-factor range. Materials and Methods: Ten healthy volunteers and 12 patients with a bulky prostate cancer underwent line scan diffusion-weighted MR imaging in which b-factors from 0 to 3000 s/mm2 in 16 steps were sampled. The acquired signal decay curves were fit with both monoexponential and biexponential signal decay functions and a statistical comparison between the two fits was performed. Results: The biexponential model provided a statistically better fit over the monoexponential model on the peripheral zone (PZ), transitional zone (TZ) and prostate cancer. The fast and slow apparent diffusion coefficients (ADCs) in the PZ, TZ and cancer were 2.9±0.2, 0.7±0.2×10-3 mm2/ms (PZ); 2.9±0.4, 0.7±0.2×10-3 mm2/ms (TZ); and 1.7±0.4, 0.3±0.1×10-3 mm2/ms (cancer), respectively. The apparent fractions of the fast diffusion component in the PZ, TZ and cancer were 70±10%, 60±10% and 50±10%, respectively. The fast and slow ADCs of cancer were significantly lower than those of TZ and PZ, and the apparent fraction of the fast diffusion component was significantly smaller in cancer than in PZ. Conclusions: Biexponential diffusion decay functions are required for prostate cancer diffusion signal decay curves when sampled over an extended b-factor range, providing additional, unique tissue characterization parameters for prostate cancer.

AB - Purpose: The purpose of this study was to investigate the need for biexponential signal decay modeling for prostate cancer diffusion signal decays with b-factor over an extended b-factor range. Materials and Methods: Ten healthy volunteers and 12 patients with a bulky prostate cancer underwent line scan diffusion-weighted MR imaging in which b-factors from 0 to 3000 s/mm2 in 16 steps were sampled. The acquired signal decay curves were fit with both monoexponential and biexponential signal decay functions and a statistical comparison between the two fits was performed. Results: The biexponential model provided a statistically better fit over the monoexponential model on the peripheral zone (PZ), transitional zone (TZ) and prostate cancer. The fast and slow apparent diffusion coefficients (ADCs) in the PZ, TZ and cancer were 2.9±0.2, 0.7±0.2×10-3 mm2/ms (PZ); 2.9±0.4, 0.7±0.2×10-3 mm2/ms (TZ); and 1.7±0.4, 0.3±0.1×10-3 mm2/ms (cancer), respectively. The apparent fractions of the fast diffusion component in the PZ, TZ and cancer were 70±10%, 60±10% and 50±10%, respectively. The fast and slow ADCs of cancer were significantly lower than those of TZ and PZ, and the apparent fraction of the fast diffusion component was significantly smaller in cancer than in PZ. Conclusions: Biexponential diffusion decay functions are required for prostate cancer diffusion signal decay curves when sampled over an extended b-factor range, providing additional, unique tissue characterization parameters for prostate cancer.

KW - Biexponential decay

KW - Diffusion

KW - MRI

KW - Prostate cancer

UR - http://www.scopus.com/inward/record.url?scp=61649122120&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=61649122120&partnerID=8YFLogxK

U2 - 10.1016/j.mri.2008.07.008

DO - 10.1016/j.mri.2008.07.008

M3 - Article

C2 - 18768281

AN - SCOPUS:61649122120

VL - 27

SP - 355

EP - 359

JO - Magnetic Resonance Imaging

JF - Magnetic Resonance Imaging

SN - 0730-725X

IS - 3

ER -