TY - JOUR
T1 - Boron-Doped Diamond as a Quasi-Reference Electrode
AU - Peng, Zhen
AU - Fiorani, Andrea
AU - Akai, Kazumi
AU - Murata, Michio
AU - Otake, Atsushi
AU - Einaga, Yasuaki
N1 - Funding Information:
This work was partially supported by Japan Science and Technology Agency and China Scholarship Council.
Publisher Copyright:
© 2022 American Chemical Society.
PY - 2022/12/6
Y1 - 2022/12/6
N2 - As a working electrode, boron-doped diamond (BDD) has been studied in detail in electrochemical processes because of its superior electrochemical properties. However, these characteristics have rarely been mentioned when BDD is used as a quasi-reference electrode (QRE). Herein, we conducted a systematic investigation on BDD electrodes, with different boron-doping levels (1 and 0.1%) and different surface terminations (hydrogen and oxygen) for their application as a QRE. A BDD electrode with 1% boron and a hydrogen-terminated surface achieved the best stability. Its open-circuit potential (OCP) exhibited less than 100 mV of potential drift over 6000 s and showed a minuscule half-wave potential difference (E1/2) of 0.0037 V in 0.1 mM K3[Fe(CN)6]/1 M KCl solution before and after the OCP measurement. Based on these observations, anions are found to contribute to the potential, which we preliminarily speculate as related to the capacitance caused by electrostatic adsorption on the positively charged hydrogen-terminated surface. The repeatability of measurement was verified through continuous cyclic voltammetry tests in 0.1 mM K3[Fe(CN)6]/1 M KCl, showing a maximum E1/2 difference of 0.042 V. The contribution of the redox couples was excluded, and the repeatability was considered to originate from its surface stability. Finally, a linear response of the optimized BDD as a QRE was validated (R2 > 0.99) by determination of free chlorine and dopamine concentrations, respectively. These results consolidate the existing fundamental research on BDD electrodes and promote the possibility of its application as a QRE in harsh environments or in vivo biological monitoring.
AB - As a working electrode, boron-doped diamond (BDD) has been studied in detail in electrochemical processes because of its superior electrochemical properties. However, these characteristics have rarely been mentioned when BDD is used as a quasi-reference electrode (QRE). Herein, we conducted a systematic investigation on BDD electrodes, with different boron-doping levels (1 and 0.1%) and different surface terminations (hydrogen and oxygen) for their application as a QRE. A BDD electrode with 1% boron and a hydrogen-terminated surface achieved the best stability. Its open-circuit potential (OCP) exhibited less than 100 mV of potential drift over 6000 s and showed a minuscule half-wave potential difference (E1/2) of 0.0037 V in 0.1 mM K3[Fe(CN)6]/1 M KCl solution before and after the OCP measurement. Based on these observations, anions are found to contribute to the potential, which we preliminarily speculate as related to the capacitance caused by electrostatic adsorption on the positively charged hydrogen-terminated surface. The repeatability of measurement was verified through continuous cyclic voltammetry tests in 0.1 mM K3[Fe(CN)6]/1 M KCl, showing a maximum E1/2 difference of 0.042 V. The contribution of the redox couples was excluded, and the repeatability was considered to originate from its surface stability. Finally, a linear response of the optimized BDD as a QRE was validated (R2 > 0.99) by determination of free chlorine and dopamine concentrations, respectively. These results consolidate the existing fundamental research on BDD electrodes and promote the possibility of its application as a QRE in harsh environments or in vivo biological monitoring.
UR - http://www.scopus.com/inward/record.url?scp=85142526410&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85142526410&partnerID=8YFLogxK
U2 - 10.1021/acs.analchem.2c03923
DO - 10.1021/acs.analchem.2c03923
M3 - Article
AN - SCOPUS:85142526410
SN - 0003-2700
VL - 94
SP - 16831
EP - 16837
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 48
ER -