Computer-assisted guidance systems for spinal instrumentation

Allen L. Carl, Morio Matsumoto

研究成果: Article

抄録

The new era of spinal implants, such as pedicle screws, has enhanced mechanical stability of the spine but also has resulted in increased risks. Misplaced pedicle screws cause complications, including neurovascular injuries and instrumentation failure. With the advent of accurate tracking devices, computer-assisted frameless image guidance has been used to improve the safety and efficacy of pedicle screw placement. Early in vitro and in vivo studies have shown that stereotaxic guidance increases the accuracy and safety of implant placement. Improvement of registration technique using intraoperative ultrasonography may extend the use of the registration technique to less invasive percutaneous indications in the future.

元の言語English
ページ(範囲)154-161
ページ数8
ジャーナルCurrent Opinion in Orthopaedics
10
発行部数2
DOI
出版物ステータスPublished - 1999
外部発表Yes

Fingerprint

Safety
Ultrasonography
Spine
Equipment and Supplies
Wounds and Injuries
Pedicle Screws
In Vitro Techniques

ASJC Scopus subject areas

  • Surgery

これを引用

Computer-assisted guidance systems for spinal instrumentation. / Carl, Allen L.; Matsumoto, Morio.

:: Current Opinion in Orthopaedics, 巻 10, 番号 2, 1999, p. 154-161.

研究成果: Article

@article{674305dcb0904f139586cd713602cb1d,
title = "Computer-assisted guidance systems for spinal instrumentation",
abstract = "The new era of spinal implants, such as pedicle screws, has enhanced mechanical stability of the spine but also has resulted in increased risks. Misplaced pedicle screws cause complications, including neurovascular injuries and instrumentation failure. With the advent of accurate tracking devices, computer-assisted frameless image guidance has been used to improve the safety and efficacy of pedicle screw placement. Early in vitro and in vivo studies have shown that stereotaxic guidance increases the accuracy and safety of implant placement. Improvement of registration technique using intraoperative ultrasonography may extend the use of the registration technique to less invasive percutaneous indications in the future.",
author = "Carl, {Allen L.} and Morio Matsumoto",
year = "1999",
doi = "10.1097/00001433-199904000-00012",
language = "English",
volume = "10",
pages = "154--161",
journal = "Current Orthopaedic Practice",
issn = "1940-7041",
publisher = "Lippincott Williams and Wilkins",
number = "2",

}

TY - JOUR

T1 - Computer-assisted guidance systems for spinal instrumentation

AU - Carl, Allen L.

AU - Matsumoto, Morio

PY - 1999

Y1 - 1999

N2 - The new era of spinal implants, such as pedicle screws, has enhanced mechanical stability of the spine but also has resulted in increased risks. Misplaced pedicle screws cause complications, including neurovascular injuries and instrumentation failure. With the advent of accurate tracking devices, computer-assisted frameless image guidance has been used to improve the safety and efficacy of pedicle screw placement. Early in vitro and in vivo studies have shown that stereotaxic guidance increases the accuracy and safety of implant placement. Improvement of registration technique using intraoperative ultrasonography may extend the use of the registration technique to less invasive percutaneous indications in the future.

AB - The new era of spinal implants, such as pedicle screws, has enhanced mechanical stability of the spine but also has resulted in increased risks. Misplaced pedicle screws cause complications, including neurovascular injuries and instrumentation failure. With the advent of accurate tracking devices, computer-assisted frameless image guidance has been used to improve the safety and efficacy of pedicle screw placement. Early in vitro and in vivo studies have shown that stereotaxic guidance increases the accuracy and safety of implant placement. Improvement of registration technique using intraoperative ultrasonography may extend the use of the registration technique to less invasive percutaneous indications in the future.

UR - http://www.scopus.com/inward/record.url?scp=0032786235&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032786235&partnerID=8YFLogxK

U2 - 10.1097/00001433-199904000-00012

DO - 10.1097/00001433-199904000-00012

M3 - Article

AN - SCOPUS:0032786235

VL - 10

SP - 154

EP - 161

JO - Current Orthopaedic Practice

JF - Current Orthopaedic Practice

SN - 1940-7041

IS - 2

ER -