Concept of functional visual acuity and its applications

Minako Kaido, Murat Dogru, Reiko Ishida, Kazuo Tsubota

研究成果: Article

60 引用 (Scopus)

抄録

Functional visual acuity (FVA) has been suggested to reflect an individual's performance in relation to certain daily activities involving visual tasks. The concept of FVA has been thought applicable to the detection of masked impairment of visual function in patients with dry eye who complain of decreased visual acuity despite normal conventional visual acuity. A stable tear-film layer over the surface of the cornea is essential for a smooth ocular surface and the formation of clear visual images. In dry eye, the ocular surface tends to dry out when normal blinking is suppressed during gazing, and patients with dry eye may have problems maintaining clear vision while gazing. The FVA measurement system is a device to measure changes in continuous visual acuity over time. Visual maintenance ratio (VMR) is the ratio between FVA and baseline visual acuity. FVA and VMR are indices for the assessment of functional vision. FVA has been thought applicable to the detection of changes in functional vision in relation to the tear film over the ocular surface. It may also be useful for the assessment of subjective visual complaints in diseases that do not involve dry eye.

元の言語English
ジャーナルCornea
26
発行部数SUPPL. 1
DOI
出版物ステータスPublished - 2007 10

Fingerprint

Visual Acuity
Tears
Maintenance
Blinking
Vision Disorders
Cornea
Equipment and Supplies

ASJC Scopus subject areas

  • Ophthalmology

これを引用

Concept of functional visual acuity and its applications. / Kaido, Minako; Dogru, Murat; Ishida, Reiko; Tsubota, Kazuo.

:: Cornea, 巻 26, 番号 SUPPL. 1, 10.2007.

研究成果: Article

Kaido, Minako ; Dogru, Murat ; Ishida, Reiko ; Tsubota, Kazuo. / Concept of functional visual acuity and its applications. :: Cornea. 2007 ; 巻 26, 番号 SUPPL. 1.
@article{b75ce7ed0c4245f4bc7417b7b50abf2d,
title = "Concept of functional visual acuity and its applications",
abstract = "Functional visual acuity (FVA) has been suggested to reflect an individual's performance in relation to certain daily activities involving visual tasks. The concept of FVA has been thought applicable to the detection of masked impairment of visual function in patients with dry eye who complain of decreased visual acuity despite normal conventional visual acuity. A stable tear-film layer over the surface of the cornea is essential for a smooth ocular surface and the formation of clear visual images. In dry eye, the ocular surface tends to dry out when normal blinking is suppressed during gazing, and patients with dry eye may have problems maintaining clear vision while gazing. The FVA measurement system is a device to measure changes in continuous visual acuity over time. Visual maintenance ratio (VMR) is the ratio between FVA and baseline visual acuity. FVA and VMR are indices for the assessment of functional vision. FVA has been thought applicable to the detection of changes in functional vision in relation to the tear film over the ocular surface. It may also be useful for the assessment of subjective visual complaints in diseases that do not involve dry eye.",
keywords = "Dry eye, Functional visual acuity, Stevens-Johnson syndrome, Tear film, Visual maintenance ratio",
author = "Minako Kaido and Murat Dogru and Reiko Ishida and Kazuo Tsubota",
year = "2007",
month = "10",
doi = "10.1097/ICO.0b013e31812f6913",
language = "English",
volume = "26",
journal = "Cornea",
issn = "0277-3740",
publisher = "Lippincott Williams and Wilkins",
number = "SUPPL. 1",

}

TY - JOUR

T1 - Concept of functional visual acuity and its applications

AU - Kaido, Minako

AU - Dogru, Murat

AU - Ishida, Reiko

AU - Tsubota, Kazuo

PY - 2007/10

Y1 - 2007/10

N2 - Functional visual acuity (FVA) has been suggested to reflect an individual's performance in relation to certain daily activities involving visual tasks. The concept of FVA has been thought applicable to the detection of masked impairment of visual function in patients with dry eye who complain of decreased visual acuity despite normal conventional visual acuity. A stable tear-film layer over the surface of the cornea is essential for a smooth ocular surface and the formation of clear visual images. In dry eye, the ocular surface tends to dry out when normal blinking is suppressed during gazing, and patients with dry eye may have problems maintaining clear vision while gazing. The FVA measurement system is a device to measure changes in continuous visual acuity over time. Visual maintenance ratio (VMR) is the ratio between FVA and baseline visual acuity. FVA and VMR are indices for the assessment of functional vision. FVA has been thought applicable to the detection of changes in functional vision in relation to the tear film over the ocular surface. It may also be useful for the assessment of subjective visual complaints in diseases that do not involve dry eye.

AB - Functional visual acuity (FVA) has been suggested to reflect an individual's performance in relation to certain daily activities involving visual tasks. The concept of FVA has been thought applicable to the detection of masked impairment of visual function in patients with dry eye who complain of decreased visual acuity despite normal conventional visual acuity. A stable tear-film layer over the surface of the cornea is essential for a smooth ocular surface and the formation of clear visual images. In dry eye, the ocular surface tends to dry out when normal blinking is suppressed during gazing, and patients with dry eye may have problems maintaining clear vision while gazing. The FVA measurement system is a device to measure changes in continuous visual acuity over time. Visual maintenance ratio (VMR) is the ratio between FVA and baseline visual acuity. FVA and VMR are indices for the assessment of functional vision. FVA has been thought applicable to the detection of changes in functional vision in relation to the tear film over the ocular surface. It may also be useful for the assessment of subjective visual complaints in diseases that do not involve dry eye.

KW - Dry eye

KW - Functional visual acuity

KW - Stevens-Johnson syndrome

KW - Tear film

KW - Visual maintenance ratio

UR - http://www.scopus.com/inward/record.url?scp=34548828263&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34548828263&partnerID=8YFLogxK

U2 - 10.1097/ICO.0b013e31812f6913

DO - 10.1097/ICO.0b013e31812f6913

M3 - Article

C2 - 17881912

AN - SCOPUS:34548828263

VL - 26

JO - Cornea

JF - Cornea

SN - 0277-3740

IS - SUPPL. 1