抄録
The mean in vitro dissolution times {in vitro MDT) of ampicillin products were evaluated from the dissolution curves in distilled water using the USP-XX dissolution apparatus, and were compared with the mean in vivo dissolution times (in vivo MDT) reported previously. In both in vivo and in vitro cases, MDT of the trihydrate capsule was greater than those of the anhydrate capsules. A good linear correlation was observed between in vivo and in vitro MDT (r = 0.999, p <0.001).
本文言語 | English |
---|---|
ページ(範囲) | 370-372 |
ページ数 | 3 |
ジャーナル | Journal of Pharmacobio-Dynamics |
巻 | 5 |
号 | 5 |
DOI | |
出版ステータス | Published - 1982 |
外部発表 | はい |
ASJC Scopus subject areas
- 薬理学