Determination of carbohydrates in food samples by capillary electrophoresis with indirect UV detection

Tomoyoshi Soga, Maria Serwe

研究成果: Article

100 引用 (Scopus)

抄録

An easy and reproducible capillary electrophoretic method with indirect UV detection for the determination of carbohydrates in food samples was described. A highly alkaline pH condition was used in order to charge every carbohydrate negatively. Electroosmotic flow (EOF) was reversed to detect sugar alcohols and to improve the separation of neutral and amino sugars. Under optimized conditions 28 carbohydrates including mono- and disaccharides, uronic acids, sialic acids, amino sugars and sugar alcohols were separated in less than 25 min. The detection limits for fructose, glucose and sucrose were in the range from 12 to 16 mg l-1 with pressure injection of 50 mbar for 6 s (ca. 6 nl) at a signal to noise ratio of 3. The calibration curves were linear over the range from 50 to 10 000 mg l-1 with correlation coefficients better than 0.9999. This method could be readily applied to the analysis of carbohydrates in several foods and beverages. Sample preparation was minimal and consisted either of dilution or dilution with filtration. (C) 2000 Elsevier Science Ltd.

元の言語English
ページ(範囲)339-344
ページ数6
ジャーナルFood Chemistry
69
発行部数3
DOI
出版物ステータスPublished - 2000 5 15
外部発表Yes

Fingerprint

Capillary electrophoresis
capillary electrophoresis
Capillary Electrophoresis
foods
Carbohydrates
carbohydrates
Sugar Alcohols
Amino Sugars
sugar alcohols
Food
amino sugars
Dilution
Electroosmosis
Sialic Acids
Uronic Acids
Food and Beverages
sampling
Beverages
sialic acids
uronic acids

ASJC Scopus subject areas

  • Food Science

これを引用

Determination of carbohydrates in food samples by capillary electrophoresis with indirect UV detection. / Soga, Tomoyoshi; Serwe, Maria.

:: Food Chemistry, 巻 69, 番号 3, 15.05.2000, p. 339-344.

研究成果: Article

@article{37c45a27d9a4462eb63b7b8324702a7c,
title = "Determination of carbohydrates in food samples by capillary electrophoresis with indirect UV detection",
abstract = "An easy and reproducible capillary electrophoretic method with indirect UV detection for the determination of carbohydrates in food samples was described. A highly alkaline pH condition was used in order to charge every carbohydrate negatively. Electroosmotic flow (EOF) was reversed to detect sugar alcohols and to improve the separation of neutral and amino sugars. Under optimized conditions 28 carbohydrates including mono- and disaccharides, uronic acids, sialic acids, amino sugars and sugar alcohols were separated in less than 25 min. The detection limits for fructose, glucose and sucrose were in the range from 12 to 16 mg l-1 with pressure injection of 50 mbar for 6 s (ca. 6 nl) at a signal to noise ratio of 3. The calibration curves were linear over the range from 50 to 10 000 mg l-1 with correlation coefficients better than 0.9999. This method could be readily applied to the analysis of carbohydrates in several foods and beverages. Sample preparation was minimal and consisted either of dilution or dilution with filtration. (C) 2000 Elsevier Science Ltd.",
keywords = "Analysis, Capillary electrophoresis, Carbohydrates, Foods",
author = "Tomoyoshi Soga and Maria Serwe",
year = "2000",
month = "5",
day = "15",
doi = "10.1016/S0308-8146(00)00044-3",
language = "English",
volume = "69",
pages = "339--344",
journal = "Food Chemistry",
issn = "0308-8146",
publisher = "Elsevier Limited",
number = "3",

}

TY - JOUR

T1 - Determination of carbohydrates in food samples by capillary electrophoresis with indirect UV detection

AU - Soga, Tomoyoshi

AU - Serwe, Maria

PY - 2000/5/15

Y1 - 2000/5/15

N2 - An easy and reproducible capillary electrophoretic method with indirect UV detection for the determination of carbohydrates in food samples was described. A highly alkaline pH condition was used in order to charge every carbohydrate negatively. Electroosmotic flow (EOF) was reversed to detect sugar alcohols and to improve the separation of neutral and amino sugars. Under optimized conditions 28 carbohydrates including mono- and disaccharides, uronic acids, sialic acids, amino sugars and sugar alcohols were separated in less than 25 min. The detection limits for fructose, glucose and sucrose were in the range from 12 to 16 mg l-1 with pressure injection of 50 mbar for 6 s (ca. 6 nl) at a signal to noise ratio of 3. The calibration curves were linear over the range from 50 to 10 000 mg l-1 with correlation coefficients better than 0.9999. This method could be readily applied to the analysis of carbohydrates in several foods and beverages. Sample preparation was minimal and consisted either of dilution or dilution with filtration. (C) 2000 Elsevier Science Ltd.

AB - An easy and reproducible capillary electrophoretic method with indirect UV detection for the determination of carbohydrates in food samples was described. A highly alkaline pH condition was used in order to charge every carbohydrate negatively. Electroosmotic flow (EOF) was reversed to detect sugar alcohols and to improve the separation of neutral and amino sugars. Under optimized conditions 28 carbohydrates including mono- and disaccharides, uronic acids, sialic acids, amino sugars and sugar alcohols were separated in less than 25 min. The detection limits for fructose, glucose and sucrose were in the range from 12 to 16 mg l-1 with pressure injection of 50 mbar for 6 s (ca. 6 nl) at a signal to noise ratio of 3. The calibration curves were linear over the range from 50 to 10 000 mg l-1 with correlation coefficients better than 0.9999. This method could be readily applied to the analysis of carbohydrates in several foods and beverages. Sample preparation was minimal and consisted either of dilution or dilution with filtration. (C) 2000 Elsevier Science Ltd.

KW - Analysis

KW - Capillary electrophoresis

KW - Carbohydrates

KW - Foods

UR - http://www.scopus.com/inward/record.url?scp=0034657612&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0034657612&partnerID=8YFLogxK

U2 - 10.1016/S0308-8146(00)00044-3

DO - 10.1016/S0308-8146(00)00044-3

M3 - Article

AN - SCOPUS:0034657612

VL - 69

SP - 339

EP - 344

JO - Food Chemistry

JF - Food Chemistry

SN - 0308-8146

IS - 3

ER -