Development of a electron tracking compton gamma-ray camera using a gas micro-tracking device for nuclear medicine

S. Kabuki, K. Hattori, H. Kawashima, H. Kimura, R. Kohara, A. Kubo, H. Kubo, S. Kurosawa, E. Kunieda, O. Miyazaki, T. Nagayoshi, Tadaki Nakahara, T. Nakazawa, H. Nishimura, K. Ogawa, Y. Okada, R. Orito, H. Saji, H. Sekiya, T. ShirahataA. Takada, T. Tanimori, M. Ueda, K. Ueno, E. Yamamoto, K. Miuchi

研究成果: Conference contribution

2 引用 (Scopus)

抜粋

The Electron Tracking Compton Gamma-Ray Camera is consisted of two detectors which are a scatter detector and absorb detector. The scatter detector is a Time Projection Chamber which spatial resolution is 0.4 mm and energy resolution is 25% at 22 keV. This system can take the recoiled electron track and energy. The absorb detector which catches the position and energy of a scattered gamma-ray. This detector is consisted of GSO scintillator and multianode photomultiplier tube. A position resolution is 6 mm and the energy resolution is 11% at 662 keV. A spatial resolution of this whole system is 3 cm at 10cm distance from detector and the efficiency is 10-5 sec -1 cm-2. And, we report the various kinds of images.

元の言語English
ホスト出版物のタイトルIEEE Nuclear Science Symposium Conference Record
ページ2971-2975
ページ数5
5
DOI
出版物ステータスPublished - 2007
イベント2006 IEEE Nuclear Science Symposium, Medical Imaging Conference and 15th International Workshop on Room-Temperature Semiconductor X- and Gamma-Ray Detectors, Special Focus Workshops, NSS/MIC/RTSD - San Diego, CA, United States
継続期間: 2006 10 292006 11 4

Other

Other2006 IEEE Nuclear Science Symposium, Medical Imaging Conference and 15th International Workshop on Room-Temperature Semiconductor X- and Gamma-Ray Detectors, Special Focus Workshops, NSS/MIC/RTSD
United States
San Diego, CA
期間06/10/2906/11/4

    フィンガープリント

ASJC Scopus subject areas

  • Computer Vision and Pattern Recognition
  • Industrial and Manufacturing Engineering

これを引用

Kabuki, S., Hattori, K., Kawashima, H., Kimura, H., Kohara, R., Kubo, A., ... Miuchi, K. (2007). Development of a electron tracking compton gamma-ray camera using a gas micro-tracking device for nuclear medicine. : IEEE Nuclear Science Symposium Conference Record (巻 5, pp. 2971-2975). [4179656] https://doi.org/10.1109/NSSMIC.2006.356499