Development of a new exposure monitoring system considering pulmonary ventilation (DEM 1).

T. Satoh, T. Higashi, H. Sakurai, K. Omae

研究成果: Article

9 引用 (Scopus)

抄録

Exposure evaluation is an essential facet in the assessment of the risks of exposure to toxic materials in the workplace. Presently, samples from the breathing atmosphere are measured in order to determine the level of individual exposure to toxic substances. This method, however, does not take into account the level of physical exertion during exposure. Physical activity is known to increase pulmonary ventilation by up to 10 times that of the level at rest. Thus, measurement of pulmonary ventilation, as well as the concentration of a toxic material in the air would provide valuable data in evaluating exposure. We have developed a device that measures and records the concentration of a toxic material in the air and pulmonary ventilation as predicted by heart rate both simultaneously and continuously. In this system, real time pulmonary ventilation is predicted from heart rate by using a regression equation that was obtained from the results of our study. The percentage error of predicted pulmonary ventilation at each heart rate is within 30%. The present study assessed the feasibility of the use of heart rate as the predictor of pulmonary ventilation. Our new exposure monitoring system is the first practical device that monitors the level of exposure dependent upon pulmonary ventilation and will be useful in the reevaluation of threshold limit values (TLV's) and in working management.

元の言語English
ページ(範囲)432-442
ページ数11
ジャーナルKeio Journal of Medicine
38
発行部数4
出版物ステータスPublished - 1989 12
外部発表Yes

Fingerprint

Pulmonary Ventilation
Poisons
Heart Rate
Air
Threshold Limit Values
Physical Exertion
Equipment and Supplies
Feasibility Studies
Atmosphere
Workplace
Respiration

ASJC Scopus subject areas

  • Medicine(all)

これを引用

Development of a new exposure monitoring system considering pulmonary ventilation (DEM 1). / Satoh, T.; Higashi, T.; Sakurai, H.; Omae, K.

:: Keio Journal of Medicine, 巻 38, 番号 4, 12.1989, p. 432-442.

研究成果: Article

Satoh, T, Higashi, T, Sakurai, H & Omae, K 1989, 'Development of a new exposure monitoring system considering pulmonary ventilation (DEM 1).', Keio Journal of Medicine, 巻. 38, 番号 4, pp. 432-442.
Satoh, T. ; Higashi, T. ; Sakurai, H. ; Omae, K. / Development of a new exposure monitoring system considering pulmonary ventilation (DEM 1). :: Keio Journal of Medicine. 1989 ; 巻 38, 番号 4. pp. 432-442.
@article{f757d2646e7f453ea83c1cb44654d3fb,
title = "Development of a new exposure monitoring system considering pulmonary ventilation (DEM 1).",
abstract = "Exposure evaluation is an essential facet in the assessment of the risks of exposure to toxic materials in the workplace. Presently, samples from the breathing atmosphere are measured in order to determine the level of individual exposure to toxic substances. This method, however, does not take into account the level of physical exertion during exposure. Physical activity is known to increase pulmonary ventilation by up to 10 times that of the level at rest. Thus, measurement of pulmonary ventilation, as well as the concentration of a toxic material in the air would provide valuable data in evaluating exposure. We have developed a device that measures and records the concentration of a toxic material in the air and pulmonary ventilation as predicted by heart rate both simultaneously and continuously. In this system, real time pulmonary ventilation is predicted from heart rate by using a regression equation that was obtained from the results of our study. The percentage error of predicted pulmonary ventilation at each heart rate is within 30{\%}. The present study assessed the feasibility of the use of heart rate as the predictor of pulmonary ventilation. Our new exposure monitoring system is the first practical device that monitors the level of exposure dependent upon pulmonary ventilation and will be useful in the reevaluation of threshold limit values (TLV's) and in working management.",
author = "T. Satoh and T. Higashi and H. Sakurai and K. Omae",
year = "1989",
month = "12",
language = "English",
volume = "38",
pages = "432--442",
journal = "Keio Journal of Medicine",
issn = "0022-9717",
publisher = "Keio University School of Medicine",
number = "4",

}

TY - JOUR

T1 - Development of a new exposure monitoring system considering pulmonary ventilation (DEM 1).

AU - Satoh, T.

AU - Higashi, T.

AU - Sakurai, H.

AU - Omae, K.

PY - 1989/12

Y1 - 1989/12

N2 - Exposure evaluation is an essential facet in the assessment of the risks of exposure to toxic materials in the workplace. Presently, samples from the breathing atmosphere are measured in order to determine the level of individual exposure to toxic substances. This method, however, does not take into account the level of physical exertion during exposure. Physical activity is known to increase pulmonary ventilation by up to 10 times that of the level at rest. Thus, measurement of pulmonary ventilation, as well as the concentration of a toxic material in the air would provide valuable data in evaluating exposure. We have developed a device that measures and records the concentration of a toxic material in the air and pulmonary ventilation as predicted by heart rate both simultaneously and continuously. In this system, real time pulmonary ventilation is predicted from heart rate by using a regression equation that was obtained from the results of our study. The percentage error of predicted pulmonary ventilation at each heart rate is within 30%. The present study assessed the feasibility of the use of heart rate as the predictor of pulmonary ventilation. Our new exposure monitoring system is the first practical device that monitors the level of exposure dependent upon pulmonary ventilation and will be useful in the reevaluation of threshold limit values (TLV's) and in working management.

AB - Exposure evaluation is an essential facet in the assessment of the risks of exposure to toxic materials in the workplace. Presently, samples from the breathing atmosphere are measured in order to determine the level of individual exposure to toxic substances. This method, however, does not take into account the level of physical exertion during exposure. Physical activity is known to increase pulmonary ventilation by up to 10 times that of the level at rest. Thus, measurement of pulmonary ventilation, as well as the concentration of a toxic material in the air would provide valuable data in evaluating exposure. We have developed a device that measures and records the concentration of a toxic material in the air and pulmonary ventilation as predicted by heart rate both simultaneously and continuously. In this system, real time pulmonary ventilation is predicted from heart rate by using a regression equation that was obtained from the results of our study. The percentage error of predicted pulmonary ventilation at each heart rate is within 30%. The present study assessed the feasibility of the use of heart rate as the predictor of pulmonary ventilation. Our new exposure monitoring system is the first practical device that monitors the level of exposure dependent upon pulmonary ventilation and will be useful in the reevaluation of threshold limit values (TLV's) and in working management.

UR - http://www.scopus.com/inward/record.url?scp=0024811202&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024811202&partnerID=8YFLogxK

M3 - Article

C2 - 2630781

AN - SCOPUS:0024811202

VL - 38

SP - 432

EP - 442

JO - Keio Journal of Medicine

JF - Keio Journal of Medicine

SN - 0022-9717

IS - 4

ER -