Diagnostic Accuracy of Ultrasound for the Directionality of Testicular Rotation and the Degree of Spermatic Cord Twist in Pediatric Patients With Testicular Torsion

Takahiro Hosokawa, Hiroaki Takahashi, Yutaka Tanami, Yumiko Sato, Tetsuya Ishimaru, Yujiro Tanaka, Hiroshi Kawashima, Eiji Oguma, Yoshitake Yamada

研究成果: Article査読

1 被引用数 (Scopus)

抄録

Objectives: To evaluate the diagnostic accuracy of ultrasound (US) to diagnose the directionality of testicular rotation and the degree of spermatic cord twist in pediatric patients with testicular torsion. Methods: A retrospective review of 14 pediatric patients with testicular torsion was conducted. The directionality of testicular rotation was classified as an inner or outer direction (inner, counterclockwise in the left testis [viewed from below] and clockwise in the right testis; and outer, counterclockwise in the right testis and clockwise in the left testis). The Clopper-Pearson method and the Fisher exact, Mann-Whitney U, and Wilcoxon signed rank sum tests were used for the statistical analyses. Results: The diagnostic accuracy of US in the directionality of testicular rotation and the degree of spermatic cord twist were 78.6% (11 of 14; 95% confidence interval, 49.2%–95.3%) and 36.4% (4 of 11; 95% confidence interval, 10.9%–69.2%), respectively. Outer rotation was seen in 50.0% of the cases. The directionality of testicular rotation and the degree of spermatic cord twist as determined by US were not significantly different between the patients with salvaged testis and those with testicular loss (inner/outer direction, 4/2 versus 4/4; P =.627; mean twist ± SD, 330.0° ± 73.5° versus 337.5° ± 115.4°; P >.999). There was no significant difference in the degree of spermatic cord twist determined by US and surgical results (343.0° ± 97.1° versus 458.2° ± 168.2°; P =.063). Conclusions: The accuracy of US in determining the directionality of testicular rotation was relatively high in our small cohort. This information may be useful for pediatric surgeons and urologists when performing early manual reduction for testicular torsion.

本文言語English
ページ(範囲)119-126
ページ数8
ジャーナルJournal of Ultrasound in Medicine
39
1
DOI
出版ステータスPublished - 2020 1 1

ASJC Scopus subject areas

  • 放射線技術および超音波技術
  • 放射線学、核医学およびイメージング

フィンガープリント

「Diagnostic Accuracy of Ultrasound for the Directionality of Testicular Rotation and the Degree of Spermatic Cord Twist in Pediatric Patients With Testicular Torsion」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル