DISTORTED PRESSURE HISTORIES DUE TO THE STEP RESPONSES IN A LINEAR TAPERED PIPE - 5. CASE OF A TANK BEING INSTALLED AT THE END.

Takahiko Tanahashi, Yutaka Yamashita, Tatsuo Sawada, Tsuneyo Ando

研究成果: Article査読

3 被引用数 (Scopus)

抄録

Distorted pressure histories in a linear tapered tube equipped with a tank at the end are experimentally investigated by the step pressure input. And also this problem is theoretically solved by two methods, i. e. , eigenfunction expansion and asymptotic expansion. The peak pressure in the tube can be controlled by the capacity of the tank. large capacity leads to an open end situation. The height of the pressure wave is proportional to the inverse of the tube radius. A one dimensional wave equation including the viscous term in the equation of motion and the effect of the variable cross section is simplified by special transformation, and the simplified equation is solved by the method of the Laplace transform. The resultant analytical solution has a clearer representation than Schuder-Binder's solution.

本文言語English
ページ(範囲)1521-1528
ページ数8
ジャーナルBulletin of the JSME
25
208
DOI
出版ステータスPublished - 1982
外部発表はい

ASJC Scopus subject areas

  • 工学(全般)

フィンガープリント

「DISTORTED PRESSURE HISTORIES DUE TO THE STEP RESPONSES IN A LINEAR TAPERED PIPE - 5. CASE OF A TANK BEING INSTALLED AT THE END.」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル