Estimation by regularized process tomography of partially filled flow with electro-magnetic induction

Miki Sakuratani, Satoshi Honda

研究成果: Conference contribution

抄録

Electromagnetic flowmeters have been one of the standard instrument to measure the conductive liquid flowrate in industry. It is possible to evaluate velocity profiles through the proper design of the magnetic field and the electrodes. In this study, we try to reconstruct the flow field in partially filled pipes (open channels) by using the weight vector corresponding to the water level, which is an expansion from fully filled flow tomography. The accuracy is improved by regularization technique and multiple regularization parameters are optimized rapidly by minimizing Minimum Distance Function related to an L-surface.

本文言語English
ホスト出版物のタイトルSICE 2011 - SICE Annual Conference 2011, Final Program and Abstracts
出版社Society of Instrument and Control Engineers (SICE)
ページ2335-2340
ページ数6
ISBN(印刷版)9784907764395
出版ステータスPublished - 2011 1 1
イベント50th Annual Conference on Society of Instrument and Control Engineers, SICE 2011 - Tokyo, Japan
継続期間: 2011 9 132011 9 18

出版物シリーズ

名前Proceedings of the SICE Annual Conference

Other

Other50th Annual Conference on Society of Instrument and Control Engineers, SICE 2011