Estimation of dynamic characteristics of a medium height office building with passive dampers considering vertical seismic response

Misaki Ishikawa, Akira Mita

研究成果: Conference contribution

抄録

In this paper, dynamic characteristics of a medium-height office building with passive dampers is investigated. The building considered here is equipped with two kinds of passive dampers, viscous vibration control walls and low yield point steel-based buckling resistant braces. Eleven accelerometers are installed on basement, 1st, 5th, 10th and 14th floor. Two displacement meters for measuring the response of dampers are installed. To know the real performance of the building, we consider not only horizontal components but also vertical components. Dynamic characteristics of the building under several earthquakes are analyzed using multi-input and multi-output models for system identification. Using acceleration responses of multiple observation points, dynamic characteristics are estimated more precisely. The estimation errors of modal parameters are obtained simultaneously. Applying the method, it is indicated that vertical input has a significant influence on translational components.

元の言語English
ホスト出版物のタイトルProceedings of SPIE - The International Society for Optical Engineering
7981
DOI
出版物ステータスPublished - 2011
イベントSensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace Systems 2011 - San Diego, CA, United States
継続期間: 2011 3 72011 3 10

Other

OtherSensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace Systems 2011
United States
San Diego, CA
期間11/3/711/3/10

Fingerprint

Seismic Response
Office buildings
Damper
dampers
Seismic response
Dynamic Characteristics
dynamic characteristics
Vertical
Braces
Vibration Control
Steel
Accelerometer
Vibration control
Estimation Error
System Identification
Buckling
Earthquake
Accelerometers
Error analysis
system identification

ASJC Scopus subject areas

  • Applied Mathematics
  • Computer Science Applications
  • Electrical and Electronic Engineering
  • Electronic, Optical and Magnetic Materials
  • Condensed Matter Physics

これを引用

Ishikawa, M., & Mita, A. (2011). Estimation of dynamic characteristics of a medium height office building with passive dampers considering vertical seismic response. : Proceedings of SPIE - The International Society for Optical Engineering (巻 7981). [79814D] https://doi.org/10.1117/12.880198

Estimation of dynamic characteristics of a medium height office building with passive dampers considering vertical seismic response. / Ishikawa, Misaki; Mita, Akira.

Proceedings of SPIE - The International Society for Optical Engineering. 巻 7981 2011. 79814D.

研究成果: Conference contribution

Ishikawa, M & Mita, A 2011, Estimation of dynamic characteristics of a medium height office building with passive dampers considering vertical seismic response. : Proceedings of SPIE - The International Society for Optical Engineering. 巻. 7981, 79814D, Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace Systems 2011, San Diego, CA, United States, 11/3/7. https://doi.org/10.1117/12.880198
Ishikawa, Misaki ; Mita, Akira. / Estimation of dynamic characteristics of a medium height office building with passive dampers considering vertical seismic response. Proceedings of SPIE - The International Society for Optical Engineering. 巻 7981 2011.
@inproceedings{a86e3ce8fb4e441083091ef255e1d561,
title = "Estimation of dynamic characteristics of a medium height office building with passive dampers considering vertical seismic response",
abstract = "In this paper, dynamic characteristics of a medium-height office building with passive dampers is investigated. The building considered here is equipped with two kinds of passive dampers, viscous vibration control walls and low yield point steel-based buckling resistant braces. Eleven accelerometers are installed on basement, 1st, 5th, 10th and 14th floor. Two displacement meters for measuring the response of dampers are installed. To know the real performance of the building, we consider not only horizontal components but also vertical components. Dynamic characteristics of the building under several earthquakes are analyzed using multi-input and multi-output models for system identification. Using acceleration responses of multiple observation points, dynamic characteristics are estimated more precisely. The estimation errors of modal parameters are obtained simultaneously. Applying the method, it is indicated that vertical input has a significant influence on translational components.",
keywords = "modal analysis, multi-input and multi-output model, passive dampers, Vertical seismic response",
author = "Misaki Ishikawa and Akira Mita",
year = "2011",
doi = "10.1117/12.880198",
language = "English",
isbn = "9780819485434",
volume = "7981",
booktitle = "Proceedings of SPIE - The International Society for Optical Engineering",

}

TY - GEN

T1 - Estimation of dynamic characteristics of a medium height office building with passive dampers considering vertical seismic response

AU - Ishikawa, Misaki

AU - Mita, Akira

PY - 2011

Y1 - 2011

N2 - In this paper, dynamic characteristics of a medium-height office building with passive dampers is investigated. The building considered here is equipped with two kinds of passive dampers, viscous vibration control walls and low yield point steel-based buckling resistant braces. Eleven accelerometers are installed on basement, 1st, 5th, 10th and 14th floor. Two displacement meters for measuring the response of dampers are installed. To know the real performance of the building, we consider not only horizontal components but also vertical components. Dynamic characteristics of the building under several earthquakes are analyzed using multi-input and multi-output models for system identification. Using acceleration responses of multiple observation points, dynamic characteristics are estimated more precisely. The estimation errors of modal parameters are obtained simultaneously. Applying the method, it is indicated that vertical input has a significant influence on translational components.

AB - In this paper, dynamic characteristics of a medium-height office building with passive dampers is investigated. The building considered here is equipped with two kinds of passive dampers, viscous vibration control walls and low yield point steel-based buckling resistant braces. Eleven accelerometers are installed on basement, 1st, 5th, 10th and 14th floor. Two displacement meters for measuring the response of dampers are installed. To know the real performance of the building, we consider not only horizontal components but also vertical components. Dynamic characteristics of the building under several earthquakes are analyzed using multi-input and multi-output models for system identification. Using acceleration responses of multiple observation points, dynamic characteristics are estimated more precisely. The estimation errors of modal parameters are obtained simultaneously. Applying the method, it is indicated that vertical input has a significant influence on translational components.

KW - modal analysis

KW - multi-input and multi-output model

KW - passive dampers

KW - Vertical seismic response

UR - http://www.scopus.com/inward/record.url?scp=79956310138&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79956310138&partnerID=8YFLogxK

U2 - 10.1117/12.880198

DO - 10.1117/12.880198

M3 - Conference contribution

AN - SCOPUS:79956310138

SN - 9780819485434

VL - 7981

BT - Proceedings of SPIE - The International Society for Optical Engineering

ER -