Extraction of previously deployed stent by an entrapped cutting balloon due to the blade fracture

Akio Kawamura, Yasushi Asakura, Shiro Ishikawa, Keiko Asakura, Teruo Okabe, Akiko Yamane, Kana Fujikura, Yusuke Suzuki, Satoshi Ogawa

研究成果: Article査読

32 被引用数 (Scopus)

抄録

During treatment for in-stent restenosis, entrapment of cutting balloon occurred because of the blade fracture. Removal of the balloon caused stent extraction, inducing acute occlusion of the coronary artery. Application of cutting balloon for in-stent restenosis requires every caution against such type of complications.

本文言語English
ページ(範囲)239-243
ページ数5
ジャーナルCatheterization and Cardiovascular Interventions
57
2
DOI
出版ステータスPublished - 2002 10 1

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Cardiology and Cardiovascular Medicine

フィンガープリント 「Extraction of previously deployed stent by an entrapped cutting balloon due to the blade fracture」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル