抄録
This paper reports fluid-filled flexible micro suction-controller array (MISCA) that can hold diverse shape of objects. MISCA is made of PDMS and each suction unit works independently. Key technical issue was gas permeability of PDMS, which decreases the suction pressure for handling. We overcome this problem by using ethylene glycol as working fluid. We confirmed that MISCA filled with ethylene glycol had the highest suction pressure, and successfully demonstrated that 100 mm2-area MISCA can pull up a 75 g object, or a grooved object held by partial contact of the suction array.
本文言語 | English |
---|---|
ホスト出版物のタイトル | 2015 Transducers - 2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems, TRANSDUCERS 2015 |
出版社 | Institute of Electrical and Electronics Engineers Inc. |
ページ | 815-818 |
ページ数 | 4 |
ISBN(印刷版) | 9781479989553 |
DOI | |
出版ステータス | Published - 2015 8月 5 |
イベント | 18th International Conference on Solid-State Sensors, Actuators and Microsystems, TRANSDUCERS 2015 - Anchorage, United States 継続期間: 2015 6月 21 → 2015 6月 25 |
Other
Other | 18th International Conference on Solid-State Sensors, Actuators and Microsystems, TRANSDUCERS 2015 |
---|---|
国/地域 | United States |
City | Anchorage |
Period | 15/6/21 → 15/6/25 |
ASJC Scopus subject areas
- 器械工学
- 電子工学および電気工学