TY - JOUR
T1 - Gastroduodenal Stenting with a Flexible Stent Demonstrates Favorable Clinical Effectiveness despite Gradual Expansion
T2 - A Multicenter Prospective Study
AU - Shigoka, Hiroaki
AU - Toki, Masao
AU - Takahashi, Sho
AU - Takahara, Naminatsu
AU - Kitamura, Katsuya
AU - Iwasaki, Eisuke
AU - Nakahara, Kazunari
AU - Isayama, Hiroyuki
AU - Nakai, Yousuke
AU - Maetani, Iruru
N1 - Funding Information:
This study was funded by Boston Scientific Corporation (no. ISREND00076).
Publisher Copyright:
© 2023 by the authors.
PY - 2023/2
Y1 - 2023/2
N2 - Aims: This study aimed to evaluate the effectiveness and safety of stenting with a flexible braided self-expandable metal stent (SEMS) for unresectable malignant gastric outlet obstruction (GOO). Methods: Palliative stenting was prospectively carried out at seven university hospitals between October 2017 and August 2020. All procedures were performed using a flexible branded SEMS of the same brand. The primary endpoint was clinical success rate at 7 days after stenting. Secondary endpoints were procedural success rate, adverse events, recurrent gastric outlet obstruction (RGOO), and patient survival time. Results: Sixty patients were enrolled. The procedural and clinical success rates were 100% and 90%, respectively. RGOO occurred in 15 cases (25%). Adverse events other than RGOO were found in seven cases (12%). The 50% survival time was 75.5 days (range: 52–97 days). Median expansion rates at 1, 3, and 7 days after stenting were 55%, 65%, and 75%, respectively. Conclusions: A flexible braided stent woven with relatively thin wires was used for malignant GOO. Despite a gradual expansion with slightly lower expansile force, the stent functioned sufficiently well and showed favorable results. Clinical Trials Registry ID: UMIN000029496.
AB - Aims: This study aimed to evaluate the effectiveness and safety of stenting with a flexible braided self-expandable metal stent (SEMS) for unresectable malignant gastric outlet obstruction (GOO). Methods: Palliative stenting was prospectively carried out at seven university hospitals between October 2017 and August 2020. All procedures were performed using a flexible branded SEMS of the same brand. The primary endpoint was clinical success rate at 7 days after stenting. Secondary endpoints were procedural success rate, adverse events, recurrent gastric outlet obstruction (RGOO), and patient survival time. Results: Sixty patients were enrolled. The procedural and clinical success rates were 100% and 90%, respectively. RGOO occurred in 15 cases (25%). Adverse events other than RGOO were found in seven cases (12%). The 50% survival time was 75.5 days (range: 52–97 days). Median expansion rates at 1, 3, and 7 days after stenting were 55%, 65%, and 75%, respectively. Conclusions: A flexible braided stent woven with relatively thin wires was used for malignant GOO. Despite a gradual expansion with slightly lower expansile force, the stent functioned sufficiently well and showed favorable results. Clinical Trials Registry ID: UMIN000029496.
KW - gastric outlet obstruction
KW - gastroduodenal obstruction
KW - gastroduodenal stent
UR - http://www.scopus.com/inward/record.url?scp=85147818901&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85147818901&partnerID=8YFLogxK
U2 - 10.3390/jcm12030850
DO - 10.3390/jcm12030850
M3 - Article
AN - SCOPUS:85147818901
SN - 2077-0383
VL - 12
JO - Journal of Clinical Medicine
JF - Journal of Clinical Medicine
IS - 3
M1 - 850
ER -