TY - JOUR
T1 - High temperature heat source generation with quasi-continuous wave semiconductor lasers at power levels of 6 W for medical use
AU - Fujimoto, Takahiro
AU - Imai, Yusuke
AU - Tei, Kazuyoku
AU - Ito, Shinobu
AU - Kanazawa, Hideko
AU - Yamaguchi, Shigeru
PY - 2014/10
Y1 - 2014/10
N2 - We investigate a technology to create a high temperature heat source on the tip surface of the glass fiber proposed for medical surgery applications. Using 4 to 6 W power level semiconductor lasers at a wavelength of 980 nm, a laser coupled fiber tip was preprocessed to contain a certain amount of titanium oxide powder with a depth of 100 ìm from the tip surface so that the irradiated low laser energy could be perfectly absorbed to be transferred to thermal energy. Thus, the laser treatment can be performed without suffering from any optical characteristic of the material. A semiconductor laser was operated quasi-continuous wave mode pulse time duration of 180 ms and >95% of the laser energy was converted to thermal energy in the fiber tip. Based on two-color thermometry, by using a gated optical multichannel analyzer with a 0.25 m spectrometer in visible wavelength region, the temperature of the fiber tip was analyzed. The temperature of the heat source was measured to be in excess 3100 K.
AB - We investigate a technology to create a high temperature heat source on the tip surface of the glass fiber proposed for medical surgery applications. Using 4 to 6 W power level semiconductor lasers at a wavelength of 980 nm, a laser coupled fiber tip was preprocessed to contain a certain amount of titanium oxide powder with a depth of 100 ìm from the tip surface so that the irradiated low laser energy could be perfectly absorbed to be transferred to thermal energy. Thus, the laser treatment can be performed without suffering from any optical characteristic of the material. A semiconductor laser was operated quasi-continuous wave mode pulse time duration of 180 ms and >95% of the laser energy was converted to thermal energy in the fiber tip. Based on two-color thermometry, by using a gated optical multichannel analyzer with a 0.25 m spectrometer in visible wavelength region, the temperature of the fiber tip was analyzed. The temperature of the heat source was measured to be in excess 3100 K.
KW - glass fiber
KW - high temperature generation
KW - semiconductor laser
UR - http://www.scopus.com/inward/record.url?scp=84901709026&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84901709026&partnerID=8YFLogxK
U2 - 10.1117/1.JBO.19.10.101502
DO - 10.1117/1.JBO.19.10.101502
M3 - Article
C2 - 24853040
AN - SCOPUS:84901709026
VL - 19
JO - Journal of Biomedical Optics
JF - Journal of Biomedical Optics
SN - 1083-3668
IS - 10
M1 - 101502
ER -