Impact of Body Size on Inferior Vena Cava Parameters for Estimating Right Atrial Pressure: A Need for Standardization?

Tatsunori Taniguchi, Tomohito Ohtani, Satoshi Nakatani, Kenichi Hayashi, Osamu Yamaguchi, Issei Komuro, Yasushi Sakata

研究成果: Article査読

14 被引用数 (Scopus)

抄録

Background Inferior vena cava (IVC) diameter and its respiratory change, as determined using echocardiography, are commonly used to assess right atrial pressure (RAP). Despite the widespread use of the IVC approach for RAP assessment, the relations among body surface area (BSA), IVC diameter, and respirophasic change remain unclear. The aim of this study was to investigate the impact of BSA on IVC parameters for predicting elevated RAP. Methods Ninety consecutive patients undergoing right-heart catheterization or central venous catheter insertion were prospectively included. To investigate the impact of BSA on IVC parameters, patients were divided into higher and lower BSA groups by comparing individual BSA measurements with the median value. Optimal cutoff points of IVC parameters for detecting RAP of ≥10 mm Hg were defined using receiver operating characteristic curves. Results The median RAP and BSA were 8 mm Hg (range, 1-25 mm Hg) and 1.61 m2 (range, 1.23-2.22 m2), respectively. In all patients, the optimal cutoff point for maximal IVC diameter (IVCDmax) and IVC collapsibility for the detection of RAP ≥ 10 mm Hg were 20 mm and 49.0%, respectively. The optimal cutoff point of IVCDmax for predicting RAP of ≥10 mm Hg was significantly larger in patients with higher BSAs than in those with lower BSAs (21 vs 17 mm, P =.0342). No differences in collapsibility indices were detected between the two groups. IVCDmax was larger in men (19 ± 5 vs 17 ± 5 mm in women, P =.0347) and weakly correlated with BSA (r = 0.35, P =.0007), whereas no relation was found between IVCDmax and age. However, the partial correlation coefficient of the entire cohort demonstrated that only BSA was still associated with IVCDmax after adjusting for age and gender (partial correlation coefficient = 0.32, P =.0020). Conclusions Body size, measured as BSA, is important to consider when IVC diameter is used to assess RAP. The optimal cutoff point of IVCDmax was 21 mm for patients with larger BSAs and 17 mm for those with smaller BSAs. However, the cutoff point of IVC collapsibility was not influenced by the difference of BSA.

本文言語English
ページ(範囲)1420-1427
ページ数8
ジャーナルJournal of the American Society of Echocardiography
28
12
DOI
出版ステータスPublished - 2015 12 1
外部発表はい

ASJC Scopus subject areas

  • 放射線学、核医学およびイメージング
  • 循環器および心血管医学

フィンガープリント

「Impact of Body Size on Inferior Vena Cava Parameters for Estimating Right Atrial Pressure: A Need for Standardization?」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル