Is high flexion following total knee arthroplasty safe? Evaluation of knee joint loads in the patients during maximal flexion

Takeo Nagura, Toshiro Otani, Yasunori Suda, Hideo Matsumoto, Yoshiaki Toyama

研究成果: Article

24 引用 (Scopus)

抄録

The purpose of this study was to indicate the mechanical loads and the flexion angle at the knee during rise from maximal flexion following total knee arthroplasty (TKA). Twenty three knees were evaluated using skin marker-based motion analysis system during four different activities of daily living. The average maximum flexion was 90 degrees (34 degrees less than passive flexion) and all subjects required support for their weight to rise from maximal flexion. The external moments and the external forces at the knee during the maximal flexion were smaller than those during the stair descending activity. The results indicate that capable flexion angle for the patients following TKA is approximately 90 degrees which has smaller mechanical loads at the knee than the stair descending activity.

元の言語English
ページ(範囲)647-651
ページ数5
ジャーナルJournal of Arthroplasty
20
発行部数5
DOI
出版物ステータスPublished - 2005 8

Fingerprint

Knee Replacement Arthroplasties
Knee Joint
Knee
Activities of Daily Living
Weights and Measures
Skin

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine
  • Surgery

これを引用

Is high flexion following total knee arthroplasty safe? Evaluation of knee joint loads in the patients during maximal flexion. / Nagura, Takeo; Otani, Toshiro; Suda, Yasunori; Matsumoto, Hideo; Toyama, Yoshiaki.

:: Journal of Arthroplasty, 巻 20, 番号 5, 08.2005, p. 647-651.

研究成果: Article

Nagura, Takeo ; Otani, Toshiro ; Suda, Yasunori ; Matsumoto, Hideo ; Toyama, Yoshiaki. / Is high flexion following total knee arthroplasty safe? Evaluation of knee joint loads in the patients during maximal flexion. :: Journal of Arthroplasty. 2005 ; 巻 20, 番号 5. pp. 647-651.
@article{8044f272fafa407dbd0ef409f8704df2,
title = "Is high flexion following total knee arthroplasty safe? Evaluation of knee joint loads in the patients during maximal flexion",
abstract = "The purpose of this study was to indicate the mechanical loads and the flexion angle at the knee during rise from maximal flexion following total knee arthroplasty (TKA). Twenty three knees were evaluated using skin marker-based motion analysis system during four different activities of daily living. The average maximum flexion was 90 degrees (34 degrees less than passive flexion) and all subjects required support for their weight to rise from maximal flexion. The external moments and the external forces at the knee during the maximal flexion were smaller than those during the stair descending activity. The results indicate that capable flexion angle for the patients following TKA is approximately 90 degrees which has smaller mechanical loads at the knee than the stair descending activity.",
keywords = "Deep flexion, Mechanical load, Motion analysis, Range of motion, Total knee arthroplasty",
author = "Takeo Nagura and Toshiro Otani and Yasunori Suda and Hideo Matsumoto and Yoshiaki Toyama",
year = "2005",
month = "8",
doi = "10.1016/j.arth.2004.07.011",
language = "English",
volume = "20",
pages = "647--651",
journal = "Journal of Arthroplasty",
issn = "0883-5403",
publisher = "Churchill Livingstone",
number = "5",

}

TY - JOUR

T1 - Is high flexion following total knee arthroplasty safe? Evaluation of knee joint loads in the patients during maximal flexion

AU - Nagura, Takeo

AU - Otani, Toshiro

AU - Suda, Yasunori

AU - Matsumoto, Hideo

AU - Toyama, Yoshiaki

PY - 2005/8

Y1 - 2005/8

N2 - The purpose of this study was to indicate the mechanical loads and the flexion angle at the knee during rise from maximal flexion following total knee arthroplasty (TKA). Twenty three knees were evaluated using skin marker-based motion analysis system during four different activities of daily living. The average maximum flexion was 90 degrees (34 degrees less than passive flexion) and all subjects required support for their weight to rise from maximal flexion. The external moments and the external forces at the knee during the maximal flexion were smaller than those during the stair descending activity. The results indicate that capable flexion angle for the patients following TKA is approximately 90 degrees which has smaller mechanical loads at the knee than the stair descending activity.

AB - The purpose of this study was to indicate the mechanical loads and the flexion angle at the knee during rise from maximal flexion following total knee arthroplasty (TKA). Twenty three knees were evaluated using skin marker-based motion analysis system during four different activities of daily living. The average maximum flexion was 90 degrees (34 degrees less than passive flexion) and all subjects required support for their weight to rise from maximal flexion. The external moments and the external forces at the knee during the maximal flexion were smaller than those during the stair descending activity. The results indicate that capable flexion angle for the patients following TKA is approximately 90 degrees which has smaller mechanical loads at the knee than the stair descending activity.

KW - Deep flexion

KW - Mechanical load

KW - Motion analysis

KW - Range of motion

KW - Total knee arthroplasty

UR - http://www.scopus.com/inward/record.url?scp=23044476026&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=23044476026&partnerID=8YFLogxK

U2 - 10.1016/j.arth.2004.07.011

DO - 10.1016/j.arth.2004.07.011

M3 - Article

C2 - 16310002

AN - SCOPUS:23044476026

VL - 20

SP - 647

EP - 651

JO - Journal of Arthroplasty

JF - Journal of Arthroplasty

SN - 0883-5403

IS - 5

ER -