Lethal pulmonary air embolism caused by the removal of a double-lumen hemodialysis catheter

Hisashi Nagai, Hideyuki Maeda, Ryohei Kuroda, Masatomo Komori, Makoto Nakajima, Akina Nara, Takako Ito-Tsujimura, Kaori Shintani-Ishida, Naoki Yahagi, Ken Ichi Yoshida

研究成果: Article

7 引用 (Scopus)

抜粋

Pulmonary air embolisms due to the removal of a central venous catheter are rare, but catheter removal is known to be a high risk factor for air embolism. In particular, the removal of a large catheter, such as a double-lumen hemodialysis catheter, can allow a large amount of air to enter into the bloodstream, which often results in sudden death. So, during catheter removal, special care should be taken to prevent air from entering blood vessels, for example, to ensure that the patient's head is tilted downward, that they have inhaled and are holding their breath, and that a covering gauze and inert ointment have been applied to the exit site. We report a lethal case of pulmonary air embolism caused by the removal of a double-lumen catheter from the right internal jugular vein of a patient who was sitting up and had not been instructed to hold their breath.

元の言語English
ページ(範囲)237-238
ページ数2
ジャーナルAmerican Journal of Forensic Medicine and Pathology
35
発行部数4
DOI
出版物ステータスPublished - 2014 1 1

    フィンガープリント

ASJC Scopus subject areas

  • Pathology and Forensic Medicine

これを引用

Nagai, H., Maeda, H., Kuroda, R., Komori, M., Nakajima, M., Nara, A., Ito-Tsujimura, T., Shintani-Ishida, K., Yahagi, N., & Yoshida, K. I. (2014). Lethal pulmonary air embolism caused by the removal of a double-lumen hemodialysis catheter. American Journal of Forensic Medicine and Pathology, 35(4), 237-238. https://doi.org/10.1097/PAF.0b013e318288b1ee