Limit loads for circular wall-Thinned feeder pipes considering bend angle

Kyung Dong Bae, Jin Ho Je, Jong Sung Kim, Yun Jae Kim

研究成果: Article

抜粋

In CANDU, feeder pipes supply heavy water to pressure tube and steam generator. Under service conditions, Flow-Accelerated Corrosion (FAC) produces local wall-thinning in the feeder pipes. The wall-thinning in these pipes affects the integrity of the piping system, as verified in previous research. This paper provides limit loads for wallthinned feeder pipes with 45° and 60° bend angles, and proposes an equation that predicts the limit loads for wallthinned feeder pipes with arbitrary bend angles. On the basis of finite element limit analyses, limit loads are obtained for wall-thinned feeder pipes under in-plane bending and internal pressure. There are two cases of in-plane bending: the in-plane closing direction and the in-plane opening direction. The material is considered the effect of the large deformation, so an elastic-perfectly-plastic material is assumed in the calculations.

元の言語English
ページ(範囲)313-318
ページ数6
ジャーナルTransactions of the Korean Society of Mechanical Engineers, A
36
発行部数3
DOI
出版物ステータスPublished - 2012 3 1
外部発表Yes

    フィンガープリント

ASJC Scopus subject areas

  • Mechanical Engineering