Measuring the actual timing of liquid-reward delivery using a thermistor

Koji Toda, Shigeru Yamane, Shinya Yamamoto

研究成果: Article

抄録

Background: Determining the exact timing of reward delivery is critical in neurophysiological experiments. Despite the importance of this parameter, techniques for precisely measuring the exact delivery time of a liquid reward have been underdeveloped. Although there is always some latency between the computer command and reward delivery, the former has been used routinely to mark reward onset time. New method: To address this issue, we developed two methods of estimating the time of liquid reward delivery. First, electrical conduction between two contacts at the outlet of a pipe was detected. This technique was impractical during normal experiments but was a direct and reliable method of measuring the precise timing of water outflow. Second, a self-heating thermistor inside the fluid delivery pipe was used. The thermistor detected a decrease in temperature upon commencement of water flow. Results: The electrical contact began 50-80. ms after the computer command. The thermistor-based delivery timing estimation was ~40. ms later than that measured by the electrical contact. The time lag was constant with minimal variance between trials within the same experimental setup. Comparison with existing method: As far as the time difference between the two methods is measured, the timing of water outflow can be estimated using the thermistor-based device. This is the first method of estimating the onset time of water flow during experiments. Conclusions: Our new system could be used to quantify setup-dependent changes in the timing of reward delivery, improving the sophistication of reward assessments in neurophysiological experiments.

元の言語English
ページ(範囲)108-113
ページ数6
ジャーナルJournal of Neuroscience Methods
229
DOI
出版物ステータスPublished - 2014 5 30
外部発表Yes

Fingerprint

Reward
Water
Heating
Equipment and Supplies
Temperature

ASJC Scopus subject areas

  • Neuroscience(all)

これを引用

Measuring the actual timing of liquid-reward delivery using a thermistor. / Toda, Koji; Yamane, Shigeru; Yamamoto, Shinya.

:: Journal of Neuroscience Methods, 巻 229, 30.05.2014, p. 108-113.

研究成果: Article

Toda, Koji ; Yamane, Shigeru ; Yamamoto, Shinya. / Measuring the actual timing of liquid-reward delivery using a thermistor. :: Journal of Neuroscience Methods. 2014 ; 巻 229. pp. 108-113.
@article{78b50b591e9c43129236b36624799a4f,
title = "Measuring the actual timing of liquid-reward delivery using a thermistor",
abstract = "Background: Determining the exact timing of reward delivery is critical in neurophysiological experiments. Despite the importance of this parameter, techniques for precisely measuring the exact delivery time of a liquid reward have been underdeveloped. Although there is always some latency between the computer command and reward delivery, the former has been used routinely to mark reward onset time. New method: To address this issue, we developed two methods of estimating the time of liquid reward delivery. First, electrical conduction between two contacts at the outlet of a pipe was detected. This technique was impractical during normal experiments but was a direct and reliable method of measuring the precise timing of water outflow. Second, a self-heating thermistor inside the fluid delivery pipe was used. The thermistor detected a decrease in temperature upon commencement of water flow. Results: The electrical contact began 50-80. ms after the computer command. The thermistor-based delivery timing estimation was ~40. ms later than that measured by the electrical contact. The time lag was constant with minimal variance between trials within the same experimental setup. Comparison with existing method: As far as the time difference between the two methods is measured, the timing of water outflow can be estimated using the thermistor-based device. This is the first method of estimating the onset time of water flow during experiments. Conclusions: Our new system could be used to quantify setup-dependent changes in the timing of reward delivery, improving the sophistication of reward assessments in neurophysiological experiments.",
keywords = "Electrical contact, Liquid reward, Neurophysiology, Thermistor, Timing estimation",
author = "Koji Toda and Shigeru Yamane and Shinya Yamamoto",
year = "2014",
month = "5",
day = "30",
doi = "10.1016/j.jneumeth.2014.04.014",
language = "English",
volume = "229",
pages = "108--113",
journal = "Journal of Neuroscience Methods",
issn = "0165-0270",
publisher = "Elsevier",

}

TY - JOUR

T1 - Measuring the actual timing of liquid-reward delivery using a thermistor

AU - Toda, Koji

AU - Yamane, Shigeru

AU - Yamamoto, Shinya

PY - 2014/5/30

Y1 - 2014/5/30

N2 - Background: Determining the exact timing of reward delivery is critical in neurophysiological experiments. Despite the importance of this parameter, techniques for precisely measuring the exact delivery time of a liquid reward have been underdeveloped. Although there is always some latency between the computer command and reward delivery, the former has been used routinely to mark reward onset time. New method: To address this issue, we developed two methods of estimating the time of liquid reward delivery. First, electrical conduction between two contacts at the outlet of a pipe was detected. This technique was impractical during normal experiments but was a direct and reliable method of measuring the precise timing of water outflow. Second, a self-heating thermistor inside the fluid delivery pipe was used. The thermistor detected a decrease in temperature upon commencement of water flow. Results: The electrical contact began 50-80. ms after the computer command. The thermistor-based delivery timing estimation was ~40. ms later than that measured by the electrical contact. The time lag was constant with minimal variance between trials within the same experimental setup. Comparison with existing method: As far as the time difference between the two methods is measured, the timing of water outflow can be estimated using the thermistor-based device. This is the first method of estimating the onset time of water flow during experiments. Conclusions: Our new system could be used to quantify setup-dependent changes in the timing of reward delivery, improving the sophistication of reward assessments in neurophysiological experiments.

AB - Background: Determining the exact timing of reward delivery is critical in neurophysiological experiments. Despite the importance of this parameter, techniques for precisely measuring the exact delivery time of a liquid reward have been underdeveloped. Although there is always some latency between the computer command and reward delivery, the former has been used routinely to mark reward onset time. New method: To address this issue, we developed two methods of estimating the time of liquid reward delivery. First, electrical conduction between two contacts at the outlet of a pipe was detected. This technique was impractical during normal experiments but was a direct and reliable method of measuring the precise timing of water outflow. Second, a self-heating thermistor inside the fluid delivery pipe was used. The thermistor detected a decrease in temperature upon commencement of water flow. Results: The electrical contact began 50-80. ms after the computer command. The thermistor-based delivery timing estimation was ~40. ms later than that measured by the electrical contact. The time lag was constant with minimal variance between trials within the same experimental setup. Comparison with existing method: As far as the time difference between the two methods is measured, the timing of water outflow can be estimated using the thermistor-based device. This is the first method of estimating the onset time of water flow during experiments. Conclusions: Our new system could be used to quantify setup-dependent changes in the timing of reward delivery, improving the sophistication of reward assessments in neurophysiological experiments.

KW - Electrical contact

KW - Liquid reward

KW - Neurophysiology

KW - Thermistor

KW - Timing estimation

UR - http://www.scopus.com/inward/record.url?scp=84899806950&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84899806950&partnerID=8YFLogxK

U2 - 10.1016/j.jneumeth.2014.04.014

DO - 10.1016/j.jneumeth.2014.04.014

M3 - Article

C2 - 24768573

AN - SCOPUS:84899806950

VL - 229

SP - 108

EP - 113

JO - Journal of Neuroscience Methods

JF - Journal of Neuroscience Methods

SN - 0165-0270

ER -