抄録
The failure process of unidirectional BN-coated HI-NICALON SiC fiber reinforced glass matrix composites was examined under tensile loading. In situ observation of the mean matrix crack interval was conducted by the replica observation during tensile testing. Axisymmetric cylindrical models extended to the system considering the strength distribution of fibers were proposed to predict the whole stress-strain curve for comparison with the experimental results.
本文言語 | English |
---|---|
ページ(範囲) | 3405-3412 |
ページ数 | 8 |
ジャーナル | Journal of Materials Science |
巻 | 34 |
号 | 14 |
DOI | |
出版ステータス | Published - 1999 1月 1 |
ASJC Scopus subject areas
- 材料科学(全般)
- 材料力学
- 機械工学