TY - JOUR
T1 - Multibeam Doppler Sensor-Based Non-Contact Heartbeat Detection Using Beam Diversity
AU - Kitagawa, Tsukiko
AU - Yamamoto, Kohei
AU - Endo, Koji
AU - Ohtsuki, Tomoaki
N1 - Publisher Copyright:
© 2013 IEEE.
PY - 2022
Y1 - 2022
N2 - Heartbeat detection could enable various applications in the medical and health care fields. In particular, non-contact heartbeat detection can be acceptable for those who have difficulty wearing devices, such as burn patients and infants. A Doppler sensor could be a key device to realize heartbeat detection without any wearable devices. Many researches in recent years have focused on heartbeat detection using a Doppler sensor with a single beam Doppler sensor. However, when the SNR (Signal-to-Noise Ratio) of heartbeat components is low for the beam direction, the heartbeat detection accuracy is likely to degrade. In this paper, for more accurate heartbeat detection, we propose a heartbeat detection method based on beam diversity using a multibeam Doppler sensor. Through the preliminary experiments, we clarified that the SNRs of heartbeat components differ from one beam to another. This means that when the SNR is low for one beam, the SNR could be high for the other beams. Inspired by this fact, the proposed method extracts heartbeat components from all peaks detected by the multi-beam signals. To verify the heartbeat detection accuracy of our method, we conducted the experiments for different detection ranges. The obtained results show that compared to the conventional methods using a single beam, our proposed method using multibeam detected heartbeat more accurately. This indicates the benefit of exploiting beam diversity, i.e., the heartbeat detection accuracy can be improved by utilizing beam diversity.
AB - Heartbeat detection could enable various applications in the medical and health care fields. In particular, non-contact heartbeat detection can be acceptable for those who have difficulty wearing devices, such as burn patients and infants. A Doppler sensor could be a key device to realize heartbeat detection without any wearable devices. Many researches in recent years have focused on heartbeat detection using a Doppler sensor with a single beam Doppler sensor. However, when the SNR (Signal-to-Noise Ratio) of heartbeat components is low for the beam direction, the heartbeat detection accuracy is likely to degrade. In this paper, for more accurate heartbeat detection, we propose a heartbeat detection method based on beam diversity using a multibeam Doppler sensor. Through the preliminary experiments, we clarified that the SNRs of heartbeat components differ from one beam to another. This means that when the SNR is low for one beam, the SNR could be high for the other beams. Inspired by this fact, the proposed method extracts heartbeat components from all peaks detected by the multi-beam signals. To verify the heartbeat detection accuracy of our method, we conducted the experiments for different detection ranges. The obtained results show that compared to the conventional methods using a single beam, our proposed method using multibeam detected heartbeat more accurately. This indicates the benefit of exploiting beam diversity, i.e., the heartbeat detection accuracy can be improved by utilizing beam diversity.
KW - Health care
KW - RRI (R-R interval)
KW - beam diversity
KW - heartbeat
KW - multibeam Doppler sensor
KW - spectrogram
KW - vital sign detection
UR - http://www.scopus.com/inward/record.url?scp=85124219215&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85124219215&partnerID=8YFLogxK
U2 - 10.1109/ACCESS.2022.3148426
DO - 10.1109/ACCESS.2022.3148426
M3 - Article
AN - SCOPUS:85124219215
SN - 2169-3536
VL - 10
SP - 16242
EP - 16253
JO - IEEE Access
JF - IEEE Access
ER -