NEW HYDRODYNAMIC OSCILLATOR TYPE FLOWMETER.

S. Honda, H. Yamasaki

研究成果: Paper

2 引用 (Scopus)

抜粋

The objectives of this study are to propose a new hydrodynamic oscillator type flowmeter and to promote a unified approach to these flowmeters. Proposed flowmeters consist of a main nozzle and a bluff cylinder, so-called target, which is derived from feedback oscillator type fluidic flowmeters by eliminating both side walls based on a topological isomorphism between fluidic flowmeters and vortex flowmeters. Since the target which diverts the jet and generates alternate vortices is inevitable to the new oscillators, it is considered as a composite of vortex flowmeters and fluidic flowmeters. The rangeability of the proposed flowmeter appeared comparable to the original fluidic flowmeter.

元の言語English
ページ623-628
ページ数6
出版物ステータスPublished - 1985 12 1

    フィンガープリント

ASJC Scopus subject areas

  • Engineering(all)

これを引用

Honda, S., & Yamasaki, H. (1985). NEW HYDRODYNAMIC OSCILLATOR TYPE FLOWMETER.. 623-628.