Normal range of intraocular pressure during enflurane anesthesia in children

R. Masuda, K. Yokoyama, K. Tsubota

研究成果: Article査読

抄録

Normal range of intraocular pressure (IOP) in children was determined by using Parkinson hand applanation tonometry under 2% enflurane and nitrous oxide in oxygen (GOE) anesthesia. Twenty atropine (0.1 mg/7 kg) premedicated ASA class 1 subjects (excluding those in whom abnormal IOP were suspected), 0-10 years of age, were studied prior to elective surgery. IOP was measured at 3 points in each subject; first IOP was measured before induction of anesthesia; 2nd and 3rd IOP were measured at 5 min. and 10 min. after the endotracheal intubation following slow induction with GOE anesthesia. A significant decrease of IOP was found without reduction of arterial pressure and heart rate under GOE anesthesia. The mean ± 2 standard deviation values considered as normal IOP range 5 and 10 minutes after intubation under 2% GOE anesthesia were from 4.2 and 13.0 mmHg and from 2.7 to 10.9 mmHg. Each institute should have its own normal IOP range in children under anesthesia for the diagnosis of congenital glaucoma.

本文言語English
ページ(範囲)325-329
ページ数5
ジャーナルJapanese Journal of Anesthesiology
34
3
出版ステータスPublished - 1985
外部発表はい

ASJC Scopus subject areas

  • 麻酔学および疼痛医療

フィンガープリント

「Normal range of intraocular pressure during enflurane anesthesia in children」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル