Partial optical path length in the scalp in subject-specific head models for multi-distance probe configuration of near infrared spectroscopy

Taku Yanagisawa, Hiroshi Kawaguchi, Takayuki Obata, Eiji Okada

研究成果: Conference contribution

抄録

In the brain function measurement by near infrared spectroscopy using a multi-distance probe configuration, the ratio of the partial optical path length in the scalp for the long spacing probe pair to that for the short spacing probe pair is important for the calculation to eliminate the scalp component in the signal. Light propagation in the subject specific head models of 45 volunteers was calculated to predict the dependence of the partial optical path length in the scalp and the weighting factor for the multi-distance probe configuration. The weighting factor ranges from 1.0 to 2.3 and increases with the scalp thickness when the scalp thickness is less than 15 mm.

元の言語English
ホスト出版物のタイトルBiomedical Imaging and Sensing Conference
出版者SPIE
10711
ISBN(電子版)9781510619791
DOI
出版物ステータスPublished - 2018 1 1
イベントBiomedical Imaging and Sensing Conference 2018 - Yokohama, Japan
継続期間: 2018 4 252018 4 27

Other

OtherBiomedical Imaging and Sensing Conference 2018
Japan
Yokohama
期間18/4/2518/4/27

Fingerprint

Near-infrared Spectroscopy
Near infrared spectroscopy
Path Length
optical paths
Probe
infrared spectroscopy
Partial
Configuration
probes
configurations
Spacing
Weighting
spacing
Light propagation
Model
brain
Brain
Eliminate
Propagation
Predict

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Condensed Matter Physics
  • Computer Science Applications
  • Applied Mathematics
  • Electrical and Electronic Engineering

これを引用

Yanagisawa, T., Kawaguchi, H., Obata, T., & Okada, E. (2018). Partial optical path length in the scalp in subject-specific head models for multi-distance probe configuration of near infrared spectroscopy. : Biomedical Imaging and Sensing Conference (巻 10711). [107111J] SPIE. https://doi.org/10.1117/12.2319286

Partial optical path length in the scalp in subject-specific head models for multi-distance probe configuration of near infrared spectroscopy. / Yanagisawa, Taku; Kawaguchi, Hiroshi; Obata, Takayuki; Okada, Eiji.

Biomedical Imaging and Sensing Conference. 巻 10711 SPIE, 2018. 107111J.

研究成果: Conference contribution

Yanagisawa, T, Kawaguchi, H, Obata, T & Okada, E 2018, Partial optical path length in the scalp in subject-specific head models for multi-distance probe configuration of near infrared spectroscopy. : Biomedical Imaging and Sensing Conference. 巻. 10711, 107111J, SPIE, Biomedical Imaging and Sensing Conference 2018, Yokohama, Japan, 18/4/25. https://doi.org/10.1117/12.2319286
Yanagisawa, Taku ; Kawaguchi, Hiroshi ; Obata, Takayuki ; Okada, Eiji. / Partial optical path length in the scalp in subject-specific head models for multi-distance probe configuration of near infrared spectroscopy. Biomedical Imaging and Sensing Conference. 巻 10711 SPIE, 2018.
@inproceedings{b8601d8ed9e148768f56b2adc982b183,
title = "Partial optical path length in the scalp in subject-specific head models for multi-distance probe configuration of near infrared spectroscopy",
abstract = "In the brain function measurement by near infrared spectroscopy using a multi-distance probe configuration, the ratio of the partial optical path length in the scalp for the long spacing probe pair to that for the short spacing probe pair is important for the calculation to eliminate the scalp component in the signal. Light propagation in the subject specific head models of 45 volunteers was calculated to predict the dependence of the partial optical path length in the scalp and the weighting factor for the multi-distance probe configuration. The weighting factor ranges from 1.0 to 2.3 and increases with the scalp thickness when the scalp thickness is less than 15 mm.",
keywords = "Near-infrared spectroscopy, short spacing probe pair",
author = "Taku Yanagisawa and Hiroshi Kawaguchi and Takayuki Obata and Eiji Okada",
year = "2018",
month = "1",
day = "1",
doi = "10.1117/12.2319286",
language = "English",
volume = "10711",
booktitle = "Biomedical Imaging and Sensing Conference",
publisher = "SPIE",

}

TY - GEN

T1 - Partial optical path length in the scalp in subject-specific head models for multi-distance probe configuration of near infrared spectroscopy

AU - Yanagisawa, Taku

AU - Kawaguchi, Hiroshi

AU - Obata, Takayuki

AU - Okada, Eiji

PY - 2018/1/1

Y1 - 2018/1/1

N2 - In the brain function measurement by near infrared spectroscopy using a multi-distance probe configuration, the ratio of the partial optical path length in the scalp for the long spacing probe pair to that for the short spacing probe pair is important for the calculation to eliminate the scalp component in the signal. Light propagation in the subject specific head models of 45 volunteers was calculated to predict the dependence of the partial optical path length in the scalp and the weighting factor for the multi-distance probe configuration. The weighting factor ranges from 1.0 to 2.3 and increases with the scalp thickness when the scalp thickness is less than 15 mm.

AB - In the brain function measurement by near infrared spectroscopy using a multi-distance probe configuration, the ratio of the partial optical path length in the scalp for the long spacing probe pair to that for the short spacing probe pair is important for the calculation to eliminate the scalp component in the signal. Light propagation in the subject specific head models of 45 volunteers was calculated to predict the dependence of the partial optical path length in the scalp and the weighting factor for the multi-distance probe configuration. The weighting factor ranges from 1.0 to 2.3 and increases with the scalp thickness when the scalp thickness is less than 15 mm.

KW - Near-infrared spectroscopy

KW - short spacing probe pair

UR - http://www.scopus.com/inward/record.url?scp=85049242333&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85049242333&partnerID=8YFLogxK

U2 - 10.1117/12.2319286

DO - 10.1117/12.2319286

M3 - Conference contribution

AN - SCOPUS:85049242333

VL - 10711

BT - Biomedical Imaging and Sensing Conference

PB - SPIE

ER -