Performance of Gd-EOB-DTPA and superparamagnetic iron oxide particles in the detection of primary liver cancer: A comparative study by alternative free-response receiver operating characteristic analysis

Akihiro Tanimoto, Y. Satoh, Y. Yuasa, Masahiro Jinzaki, K. Hiramatsu

研究成果: Article

26 引用 (Scopus)

抄録

The performance of gadolinium-ethoxybenzyl- diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) and superparamagnetic iron oxide (SPIO) particles in detecting liver cancer was compared using alternative free-response receiver operating characteristic (AFROC) analysis, which allowed observers to indicate both the confidence level and the location of all perceived abnormalities. Axial T1-weighted MR images (1.5 T) pre/post Gd-EOB-DTPA (25 μmol/kg) injection were obtained for 12 rats with chemically induced liver tumors (64 tumors). T2-weighted images (T2WI) were obtained pre/post SPIO (10 μmol/kg) injection for the same animal. Liver signal-to-noise ratio (SNR), tumor liver contrast-to-noise ratio (CNR), and histopathologic sections corresponding to MR images were obtained. In AFROC, the location and the confidence level for each tumor were indicated independently on MR images by four radiologists. By plotting true-positive fraction and probability of false-positive per image, the area under the AFROC curve (A1) was estimated and statistically analyzed between each sequence. Either drug significantly improved tumor-liver CNR (P < .001) and tumor detection (diameter ≤ 6 mm; P < .05). Gd-EOB-DTPA significantly (P < .05) improved the A1 in T1W1. There was no A1 difference between T2WI + SPIO and T1WI + Gd-EOB-DTPA. Gd-EOB-DTPA-enhanced T1WI showed the same performance as SPIO-enhanced T2WI in detecting liver tumors.

元の言語English
ページ(範囲)120-124
ページ数5
ジャーナルJournal of Magnetic Resonance Imaging
7
発行部数1
DOI
出版物ステータスPublished - 1997

Fingerprint

Liver Neoplasms
ROC Curve
Neoplasms
Liver
Noise
Injections
Signal-To-Noise Ratio
ferric oxide
gadolinium ethoxybenzyl DTPA
Pharmaceutical Preparations

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

これを引用

@article{e509477613424bd392d7db6a40b830b5,
title = "Performance of Gd-EOB-DTPA and superparamagnetic iron oxide particles in the detection of primary liver cancer: A comparative study by alternative free-response receiver operating characteristic analysis",
abstract = "The performance of gadolinium-ethoxybenzyl- diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) and superparamagnetic iron oxide (SPIO) particles in detecting liver cancer was compared using alternative free-response receiver operating characteristic (AFROC) analysis, which allowed observers to indicate both the confidence level and the location of all perceived abnormalities. Axial T1-weighted MR images (1.5 T) pre/post Gd-EOB-DTPA (25 μmol/kg) injection were obtained for 12 rats with chemically induced liver tumors (64 tumors). T2-weighted images (T2WI) were obtained pre/post SPIO (10 μmol/kg) injection for the same animal. Liver signal-to-noise ratio (SNR), tumor liver contrast-to-noise ratio (CNR), and histopathologic sections corresponding to MR images were obtained. In AFROC, the location and the confidence level for each tumor were indicated independently on MR images by four radiologists. By plotting true-positive fraction and probability of false-positive per image, the area under the AFROC curve (A1) was estimated and statistically analyzed between each sequence. Either drug significantly improved tumor-liver CNR (P < .001) and tumor detection (diameter ≤ 6 mm; P < .05). Gd-EOB-DTPA significantly (P < .05) improved the A1 in T1W1. There was no A1 difference between T2WI + SPIO and T1WI + Gd-EOB-DTPA. Gd-EOB-DTPA-enhanced T1WI showed the same performance as SPIO-enhanced T2WI in detecting liver tumors.",
keywords = "Contrast media, gadolinium, iron, magnetic resonance, Diagnosis, magnetic resonance, Experimental liver, Magnetic resonance, Neoplasm",
author = "Akihiro Tanimoto and Y. Satoh and Y. Yuasa and Masahiro Jinzaki and K. Hiramatsu",
year = "1997",
doi = "10.1002/jmri.1880070116",
language = "English",
volume = "7",
pages = "120--124",
journal = "Journal of Magnetic Resonance Imaging",
issn = "1053-1807",
publisher = "John Wiley and Sons Inc.",
number = "1",

}

TY - JOUR

T1 - Performance of Gd-EOB-DTPA and superparamagnetic iron oxide particles in the detection of primary liver cancer

T2 - A comparative study by alternative free-response receiver operating characteristic analysis

AU - Tanimoto, Akihiro

AU - Satoh, Y.

AU - Yuasa, Y.

AU - Jinzaki, Masahiro

AU - Hiramatsu, K.

PY - 1997

Y1 - 1997

N2 - The performance of gadolinium-ethoxybenzyl- diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) and superparamagnetic iron oxide (SPIO) particles in detecting liver cancer was compared using alternative free-response receiver operating characteristic (AFROC) analysis, which allowed observers to indicate both the confidence level and the location of all perceived abnormalities. Axial T1-weighted MR images (1.5 T) pre/post Gd-EOB-DTPA (25 μmol/kg) injection were obtained for 12 rats with chemically induced liver tumors (64 tumors). T2-weighted images (T2WI) were obtained pre/post SPIO (10 μmol/kg) injection for the same animal. Liver signal-to-noise ratio (SNR), tumor liver contrast-to-noise ratio (CNR), and histopathologic sections corresponding to MR images were obtained. In AFROC, the location and the confidence level for each tumor were indicated independently on MR images by four radiologists. By plotting true-positive fraction and probability of false-positive per image, the area under the AFROC curve (A1) was estimated and statistically analyzed between each sequence. Either drug significantly improved tumor-liver CNR (P < .001) and tumor detection (diameter ≤ 6 mm; P < .05). Gd-EOB-DTPA significantly (P < .05) improved the A1 in T1W1. There was no A1 difference between T2WI + SPIO and T1WI + Gd-EOB-DTPA. Gd-EOB-DTPA-enhanced T1WI showed the same performance as SPIO-enhanced T2WI in detecting liver tumors.

AB - The performance of gadolinium-ethoxybenzyl- diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) and superparamagnetic iron oxide (SPIO) particles in detecting liver cancer was compared using alternative free-response receiver operating characteristic (AFROC) analysis, which allowed observers to indicate both the confidence level and the location of all perceived abnormalities. Axial T1-weighted MR images (1.5 T) pre/post Gd-EOB-DTPA (25 μmol/kg) injection were obtained for 12 rats with chemically induced liver tumors (64 tumors). T2-weighted images (T2WI) were obtained pre/post SPIO (10 μmol/kg) injection for the same animal. Liver signal-to-noise ratio (SNR), tumor liver contrast-to-noise ratio (CNR), and histopathologic sections corresponding to MR images were obtained. In AFROC, the location and the confidence level for each tumor were indicated independently on MR images by four radiologists. By plotting true-positive fraction and probability of false-positive per image, the area under the AFROC curve (A1) was estimated and statistically analyzed between each sequence. Either drug significantly improved tumor-liver CNR (P < .001) and tumor detection (diameter ≤ 6 mm; P < .05). Gd-EOB-DTPA significantly (P < .05) improved the A1 in T1W1. There was no A1 difference between T2WI + SPIO and T1WI + Gd-EOB-DTPA. Gd-EOB-DTPA-enhanced T1WI showed the same performance as SPIO-enhanced T2WI in detecting liver tumors.

KW - Contrast media, gadolinium, iron, magnetic resonance

KW - Diagnosis, magnetic resonance

KW - Experimental liver

KW - Magnetic resonance

KW - Neoplasm

UR - http://www.scopus.com/inward/record.url?scp=0031421927&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031421927&partnerID=8YFLogxK

U2 - 10.1002/jmri.1880070116

DO - 10.1002/jmri.1880070116

M3 - Article

C2 - 9039601

AN - SCOPUS:0031421927

VL - 7

SP - 120

EP - 124

JO - Journal of Magnetic Resonance Imaging

JF - Journal of Magnetic Resonance Imaging

SN - 1053-1807

IS - 1

ER -